# Review of "The first knot's polarization map overpredicts the second knot's polarized light fourfold at the bend in 3C 380"

**Recommendation: minor revisions.**

## What the paper claims

Two bright knots crossed the same bend in the 3C 380 jet, in 2003–08 and 2019–26. The paper takes the earlier knot's fractional Q/U map at 1.2 mas, weights it by the later knot's excess brightness, and predicts 21.2% polarization in a 1.7 mas beam. It measures 5.3%. A direct estimate from the visibilities gives the same contrast. A fixed pattern on 0.2 mas cells can fit the yearly averages, but it predicts withheld years poorly.

## Do the numbers hold?

Yes. I copied the study to scratch and reran `transfer.py` and `passages.py` on the cached maps. They reproduce the table exactly:

- Earlier passage: 21.09% measured.
- Later passage: 21.17% predicted, 5.26% measured.
- If all predicted vectors were aligned: 21.33%.
- Later excess Q: 4.58 mJy/beam predicted, 0.64 measured.
- Mean yearly vector errors: 5.6 points (old→old), 3.3 (new→new) and 17.1 (old→new).

The registration and background ranges in `sensitivity.csv` (19.3–24.2% predicted against 5.1–5.6% measured) also match the text.

The visibility check is useful. It shows the contrast comes from the data and not from CLEAN or imaging. The paper correctly notes that both extractions share the same calibration.

The paper also states plainly that the contrast was noticed before the spatial test and that this one case says nothing about how often such contrasts occur. That is the right framing for a result that came out of a scan.

## Main issues

### 1. The illumination test had little room to change the answer, and the paper should say so

The paper's central step is weighting the earlier map by where the later knot is bright. Figure 2 (left) shows this step could hardly matter:

- The half-peak contours of the two knots nearly coincide.
- Across both footprints, the earlier fractional Q varies smoothly, by roughly 15–25%.

So any reasonable reweighting returns about 21%. The 0.16-point "cancellation" result follows from this geometry and is not a strong test of the hypothesis. In practice the resolved prediction restates the raw contrast: at the same 1.7 mas spot, the polarized fraction fell from 21% to 5%. This is still a valid result. The test checks the obvious explanation and excludes it. But the paper should say directly that at 1.2 mas the two knots lit up nearly the same region. Readers should not take the agreement between 21.1% and 21.2% as evidence that the method had discriminating power.

### 2. The withheld-year failure of the fine-scale model cannot count against a fixed sub-beam pattern

The paper says the 0.2 mas stationary field "missed by 11.7 points … and 7.3 … worse than the same-passage predictions." Read in context, this suggests the data disfavour a fixed fine-scale pattern. I tested whether this check has any power.

- **Setup:** I took the field fitted to all years (`total_fit.py` setup, width 0.1 mas) as the truth. From it I generated synthetic yearly Q/U that are exactly stationary. I added Gaussian noise to each fitted row and repeated the leave-one-year-out fit (script: `control.py` in my scratch directory).
- **Results:** mean withheld-year errors were:

| Noise per row | Earlier passage | Later passage |
|---:|---:|---:|
| 0 | 0.031 | 0.015 |
| 0.01 | 0.062 | 0.040 |
| 0.03 | 0.135 | 0.053 |

The observed errors of 0.117 and 0.073 fall in this range. The faint reference rows are fitted only to about 0.1, so realistic noise is not small. A field that really is fixed in time can therefore fail this test about as badly as the real data do. The check is uninformative.

**Fix:** drop the "worse than the same-passage predictions" comparison, or report it together with a stationary-truth control like this one. Then say plainly that fixed structure below about 1 mas is neither required nor excluded. The paper already comes close ("At the resolution actually measured, the earlier knot supplies a poor polarization map for the later one"). That sentence is the claim the evidence supports.

### 3. Title, `so_what` and importance overreach the supported claim

The supported claim is narrower than the framing: in one jet, at about 1 mas resolution and one frequency, the polarized fraction at the bend was not repeated.

- **Title and abstract:** these should keep the resolution qualifier.
- **`so_what`:** "A map made during one passage can give a misleading picture of what the next knot will reveal" reads as a general lesson drawn from one bend. Tie it to this jet.
- **Importance:** 3 ("changes what specialists believe") is too high. Polarization variability between successive VLBI components is well known. The new piece is a clean exclusion of the resolved-illumination explanation at one bend, which is a 2.

### 4. Polarization also falls within each passage; mention it

Rerunning the yearly values shows a decline inside each passage, not only between them:

- Earlier knot: fractional Q was 22%, 17%, 19%, 28% and 18% in 2003–07, then 10% in 2008.
- Later knot: fractional Q fell from 6.4% in 2019 to about 0–1% in 2023–26.

Within the earlier passage, 2008 is badly predicted by the other years; Figure 2 shows this. This supports the paper's conclusion that the pattern is not fixed. It also suggests a simpler physical picture: the polarization evolves with the knot, or with time at the bend, rather than being set by where the bend is lit. One or two sentences on this, plus the matching outside-window result already in NOTES ("in the departing tail of the first complex even the old predictor was high"), would help readers more than the fine-scale fitting section.

## Clarity

- **Background:** the opening explains Q/U and polarization well. It never says why a fixed pattern would be expected, for example a standing shock, or a helical or compressed field set by the bend geometry. Without that, an outside reader cannot see why "the pattern does not repeat" is informative. Two sentences would fix this.
- **Section "Structure below the resolution of the maps" and the "Unresolved model" methods:** these are dense and, given issue 2, carry little weight. They could be cut to a short paragraph: a fixed sub-beam field can fit the yearly averages, so it cannot be excluded.
- **Faraday rotation:** the single-frequency limit is stated once and correctly. Optionally, archival multi-frequency VLBA polarimetry of 1828+487 from the first passage (MOJAVE's 2006 multi-band rotation-measure epochs) might bound Faraday rotation for the earlier knot. This is a suggestion, not a condition.

## Single most important improvement

State the claim at the resolution where the data test it. Say that at 1.2 mas the two knots lit up nearly the same region, so illumination differences cannot explain the drop from 21% to 5%. Then remove or properly control the withheld-year argument, so the paper does not imply that a fixed sub-beam pattern has been disfavoured.