# Review 1

**Recommendation: minor revisions**

## What the paper claims

In heartbeat-timed (gated) CT from 20 people with abdominal aortic aneurysms, the paper tracks bright calcified markers on the spine-facing (posterior) wall. It asks whether each marker moves lengthwise with the rest of the sac or stays fixed to the nearby vertebra. In five people (ten posterior sites), separated markers on the front of the same sac predicted the posterior marker's lengthwise shift better than fixation to bone did. This held in 5/5 people between the designated diastolic and systolic images (median error 0.05 vs 0.61 mm). It held in 4/5 on the remaining phases after centering each trajectory (0.066 vs 0.153 mm; P12 favored bone).

The core claim is supported, and the title ("can move lengthwise with the sac") is pitched at the right strength. Two things need fixing: a framing that the paper's own data contradict, and the importance rating.

## What I checked

- **Downstream numbers.** I copied the study and scouting code to scratch and reran `score.py`, `check.py` and `patient_table.py` on the saved inputs. `trajectories.csv`, `scores_site.csv`, `checked_sites.csv` and `remaining_phase_errors.csv` came out byte-identical. From `checked_sites.csv` I recomputed Table 1, the systolic medians (0.612 vs 0.051 mm), the timing check (synchronous 0.097 vs out-of-step 0.311 mm, median of patient medians) and the ten-person two-phase median (0.64 mm).
- **Raw image stage.** I extracted the CT volumes and surfaces for P03, P09, P12, P13 and P16 from the archived Zenodo ZIP and reran the patch registration (`measure.py`) and the two-sample bone registration (`bone_blocks.py`). All 541 wall/bone patch fits and 210 bone-block fits matched the committed values exactly (largest difference 0.0 mm). The whole chain from native CT to the paper's table therefore reproduces for the five people who carry the claim. I did not rerun site selection or the masked image read.
- **Discriminating tests.** The phase-shift test is the strongest evidence. The same two trajectories compared out of step give errors about three times larger than in step, and 8 of 10 sites rank the true alignment first. Fixation could have won this test, and P12 shows that it sometimes does. The paper also selected sites from diastole alone, reported the funnel (264 → 27 → 25 → 19 sites → 10 sites in 5 people) and kept the person where bone won. That is a fair test.

## Main issues

**1. The "distance changes little" premise is not what the data show.** The opening paragraph, the question and `so_what` all say the wall moves along the spine "even when its distance from the spine changes little." Over all phases, the paper's own medians are 0.65 mm of lengthwise range and 0.50 mm of distance range (`all_phase_ranges.csv`). The two are comparable, and the paper says itself that the two-phase distance change is a poor guide. Even the Figure 1 example, chosen because the two-phase distance change was 0.19 mm, swings by 0.72 mm in distance across the cycle, against about 1.1 mm lengthwise. The distance measure is also fragile. At P03-k28 a 150 vs 250 HU cortex threshold gives +3.47 vs −0.09 mm. Many reference "faces" are vertebral endplate rims next to the disc; Figure 1 appears to show one. What the evidence supports is co-travel: the posterior marker shares the sac's lengthwise pulsatile shift instead of staying with bone. The paper should lead with that and drop the constant-gap framing from the first paragraph and from `so_what`. The distance data can stay as a secondary observation, with the threshold sensitivity and endplate caveat stated next to it.

**2. Say plainly what "fixed to bone" means here.** The vertebra barely moves during a heartbeat. In `checked_sites.csv`, raw wall displacement and wall-minus-bone displacement are nearly identical (ten-person systolic medians 0.59 vs 0.64 mm). So the "fixation" prediction is close to "the posterior marker does not move in the image." The test therefore asks whether the posterior marker shares the lengthwise motion of the rest of the sac. That is a legitimate question, but a reader should be told so directly. It explains why fixation loses whenever the sac moves at all and the posterior marker goes with it.

**3. State how small the effect is relative to noise, and give a simple test.** On the remaining phases the fixation errors (0.11–0.21 mm) are only about 1.5–3 times the disagreement between the two bone samples (0.04–0.09 mm in P03, P09, P13). In P16 they are about equal. These are sub-voxel shifts (slice spacing 0.7–1.5 mm). The paper gives no inferential statement. Please add one line: for example, a one-sided sign test across people gives p ≈ 0.03 for 5/5 and p ≈ 0.19 for 4/5. Also note that the phase-shift comparison is the test that does not depend on bone noise. This would let readers calibrate a five-person result without hedging every sentence.

## Smaller points

- The masked anatomical screen was done by an AI reader. That is stated in Methods. The Results call it "a masked anatomical reading", so a reader may assume a human expert. Say "AI reader" in Results as well.
- The text is dense. "Designated phases", "patch", "componentwise median" and the phase labels (percent for some people, index for others) need a short gloss where they first appear. Results paragraphs on centroid redetection and rigid bone could be shortened. They are confirmations, and Methods already holds the details.
- The remaining phases come from the same people and scans that suggested the hypothesis. The paper says this once in Interpretation, which is enough. The "additional phases" are best described as a within-cohort check, not independent replication.

## record.json

- `so_what` repeats the "even when its distance from the spine changes little" framing (issue 1). Suggested rewrite: "During each heartbeat the bulging part of the abdominal aorta shifts slightly along the spine, and in five people we could track, the back wall facing the spine shifted with it instead of staying anchored to the bone. Computer models of aneurysms sometimes treat that wall as held by the spine; these scans suggest that is wrong at least where the wall and bone are a few millimeters apart."
- `importance` level 3 is too high. The evidence is five people, sub-millimeter shifts close to the bone-noise floor in some cases, and markers 3–9 mm from bone. It informs one modeling choice (the posterior boundary condition) for separated sites. That is level 2, which matches the screen's rating.
- `summary` and `findings` are accurate and match the numbers I reproduced.

## Single most important change

Recast the claim as co-travel of the posterior wall with the sac's lengthwise motion, and remove the "distance changes little" framing from the opening and `so_what`. The all-phase data show distance and lengthwise ranges of similar size, so that framing is not supported, while the co-travel claim is supported and reproduces from the raw CT.