FindingMR

Genetically lower blood levels of the antibody IgA show no increased bacterial pneumonia risk after accounting for other antibodies

Version 1 Published 2026-11-01 DOI 10.5281/zenodo.24373470

Importance (self-rated) Notable

Narrows a specific question about serum IgA and bacterial pneumonia independently of other antibody classes; instrument assumptions and lifelong exposure prevent direct treatment-safety conclusions.

Why it matters

People whose genetic variants predict lower blood IgA, one type of antibody, showed no increase in bacterial pneumonia after accounting for two other antibody types. Several analyses weighed against a large increase, helping clarify whether lower IgA alone carries the infection risks associated with broader antibody deficiency. This does not establish that IgA-lowering medicines are safe or that losing IgA at the surfaces of the airways is harmless.

Lowering immunoglobulin A (IgA), an antibody involved in immune defense and kidney disease, raises a practical question: would reducing it increase susceptibility to pneumonia if other antibody classes were preserved? Antibodies share some genetic regulation, making an IgA-specific effect difficult to separate. We analyzed genetic predictors of IgA and two other antibody classes, immunoglobulin G (IgG) and immunoglobulin M (IgM), together. FinnGen, a Finnish study linking genetic data to health records, supplied bacterial pneumonia data comprising 22,740 cases and 409,571 controls. The estimated odds ratio per standardized-unit lower IgA in serum, the liquid portion of blood, was 0.970 (95% confidence interval 0.906–1.039), after accounting for IgG and IgM. An odds ratio of one means unchanged odds. Analyses using stronger genetic predictors and methods that reduce the influence of discordant variants also gave estimates near one. Under their respective genetic-model assumptions, these results argue against a 20% increase in broad bacterial pneumonia odds from the lifelong serum-IgA variation captured here.

Background

IgA, IgG and IgM are antibody classes, also called isotypes. They share parts of their genetic regulation, so an association between an IgA-related variant and infection could reflect changes in other antibodies. Serum IgA differs from secretory IgA, which acts at mucosal surfaces such as the respiratory tract. These distinctions matter when using population genetics to understand the infection consequences of lowering IgA.

Liu and colleagues found that IgA-increasing genetic variants tended to associate with protection against several infections, alongside evidence linking higher IgA to IgA nephropathy, a kidney disease. Their study did not separate an IgA-specific pneumonia effect from effects shared with IgG and IgM. The subsequent three-isotype study by Willis and colleagues provides genetic associations with all three antibody classes, allowing that joint comparison. [1,2]

We used multivariable Mendelian randomization, a method that uses genetic variants as predictors, or instruments, to estimate the effects of several exposures together. This method compares each variant's association with pneumonia against its associations with all three antibody levels. Its IgA coefficient estimates the effect of genetically predicted IgA variation while holding the other two isotypes fixed. A causal interpretation requires variants to predict antibody levels sufficiently strongly and to affect pneumonia through the modeled antibodies rather than other immune pathways. We assessed both requirements.

Results

Stronger genetic predictors give similar estimates

The full 91-variant model gave little evidence of increased bacterial pneumonia odds with lower IgA, but its ability to distinguish IgG from the other antibodies was limited. Conditional F statistics measure how strongly the variants predict each antibody after accounting for the others; values below 10 warn of weak identification. IgG's value was 8.07 in the full model. We therefore examined progressively stronger sets of variants, or panels, selected by their associations with antibody levels.

The two most stringent panels had conditional F values above 10 for all three antibody classes (Table 1). Their estimates remained close to unchanged pneumonia odds despite the improved separation of the antibodies. For the 24-variant panel, allowing correlated estimation errors between antibody measurements gave F values of 35.10, 15.15 and 103.30 for IgA, IgG and IgM, respectively.

Table 1. Joint genetic estimates for bacterial pneumonia across all six panels selected by antibody associations. CI means confidence interval.

Variant panel Variants Conditional F: IgA / IgG / IgM IgA odds ratio (95% CI) Heterogeneity P
Full eligible set 91 29.71 / 8.07 / 42.78 0.970 (0.906–1.039) 0.0650
Discovery I² ≤75% 86 18.73 / 5.80 / 44.75 0.933 (0.860–1.012) 0.0683
Minor-allele frequency ≥5% 87 22.04 / 6.70 / 46.40 0.941 (0.869–1.019) 0.0665
Exposure P <10⁻¹⁰ 60 31.10 / 9.36 / 53.84 0.974 (0.901–1.053) 0.0179
Exposure P <10⁻¹⁵ 34 34.15 / 12.33 / 84.00 0.991 (0.901–1.090) 0.0055
Exposure P <10⁻²⁰ 24 39.57 / 15.98 / 107.12 1.016 (0.924–1.117) 0.0747

Odds ratios are per standardized-unit lower IgA, conditional on IgG and IgM, from inverse-variance-weighted regression, which gives more weight to more precisely measured pneumonia associations. Conditional F values assume uncorrelated estimation errors between antibodies. Discovery I² measures disagreement between the contributing antibody studies; excluding values above 75% removes their most heterogeneous lead variants. Minor-allele frequency is the frequency of the less common genetic form. The exposure P thresholds select variants by the statistical strength of their antibody associations. Heterogeneity P values test whether the pneumonia associations fit a common three-antibody effect model. Panels overlap and are sensitivity analyses, not independent replications.

Estimates remain similar when discordant variants receive less weight

Methods that reduce the influence of variants inconsistent with the joint model also estimated little change in pneumonia odds (Figure 1). Across the six panels, MM regression, a robust fitting method that downweights variants whose pneumonia associations depart substantially from the fitted model, gave IgA odds ratios of 0.948–1.029, with no upper confidence limit above 1.105. Multivariable median regression, which minimizes absolute rather than squared differences between observed and fitted associations, gave odds ratios of 0.969–0.975. Its largest upper confidence limit was 1.122 across the panels and three scenarios for correlated estimation errors between antibodies, described in Methods. In the full panel, the MM estimate was 0.986 (0.910–1.068) and the median estimate was 0.974 (0.878–1.080).

Joint IgA estimates for bacterial pneumonia across six variant panels and three estimators

Figure 1. IgA estimates remain near one across instrument selections and estimators. IVW denotes inverse-variance-weighted regression; MM and median are methods that tolerate some variants affecting pneumonia through pathways outside the modeled antibodies, under additional assumptions. Bars show 95% confidence intervals; median intervals assume uncorrelated estimation errors between antibodies. The solid line marks no change in odds. The dashed line marks the prespecified 20% increase used as a research precision target, not a treatment-safety margin. The same participants contribute to every estimate.

Some variants clearly challenged the assumption that all pneumonia associations act through the three measured antibodies. Heterogeneity measures how much the variants disagree with a common effect model. The 60- and 34-variant panels showed heterogeneity (P=0.0179 and 0.0055). In the 34-variant panel, a diagnostic allowing uncertainty in all antibody coefficients also rejected a common-effect model. Its minimum discrepancy statistic was 53.65 against an acceptance threshold of 48.60. No combination of antibody effects passed this test, indicating model incompatibility. The largest departures from the fitted model came from variants rs2476601 at the gene PTPN22 and rs7590126 near the genes PUS10 and XPO1. MM regression downweighted both while retaining a near-null IgA estimate. Gene names here identify regions; they do not establish which gene causes the discrepancy.

In contrast, the full and 24-variant panels accepted a zero IgA effect in the same uncertainty-aware diagnostic and rejected an odds ratio of 1.20 under each tested covariance scenario. The approximate ranges of IgA odds ratios compatible with this diagnostic, after allowing IgG and IgM effects to vary, spanned 0.877–1.060 and 0.917–1.126, respectively. These diagnostics assume that all variants act through the modeled antibodies; the robust regressions instead allow some variants to act through other pathways.

No single variant accounted for the bounded result. When each variant was removed in turn, the largest upper confidence limit was 1.144. Alternative selection of weakly correlated variants using European and Finnish reference genetic data, or requiring wider spacing between variants, also retained near-null estimates.

Results with a different antibody assay and for pneumococcal pneumonia

The antibody meta-analysis, which combined results across studies, included conventional immunoassays and aptamer assays. Immunoassays use antibodies to measure proteins; aptamer assays use other binding reagents. We recalibrated all selected variants using public immunoassay data from EPIC-Norfolk, a contributing population study in Norfolk, England. This gave similar point estimates but insufficient conditional IgG strength to validate their precision independently. The full-panel IgA estimate was 0.960 (0.897–1.028), but IgG conditional F was only 2.82 under the full covariance scenario and remained below 10 in every panel. Because EPIC-Norfolk also contributed to discovery, this comparison checks agreement between measurement methods.

Pneumococcal pneumonia, caused by the bacterium Streptococcus pneumoniae, was a subset of the broader bacterial pneumonia outcome. This outcome, with 1,701 cases, was substantially less precise. Its full-panel IgA odds ratio was 1.143 (0.885–1.478). The broad bacterial-pneumonia result consequently cannot exclude a substantial increase for this particular pathogen.

Interpretation

The genetic evidence weighs against a large increase in broad bacterial pneumonia risk from lower serum IgA independently of IgG and IgM. This conclusion rests on agreement between stronger-instrument models and methods that reduce the influence of discordant variants, rather than on the precision of a single regression. It narrows the interpretation of earlier links between IgA genetics and infection: those links need not imply a large independent effect of circulating IgA on this endpoint.

The main remaining uncertainty is whether the variants isolate antibody quantity. Immune variants may influence infection through other functions, and robust regression cannot remove a directional bias shared across many variants. None of the methods protects simultaneously against all bias from weak genetic predictors and shared effects through other pathways. Selection of antibody-associated variants can overstate their exposure effects; mixed assays and uncertain error correlations further limit causal precision. FinnGen diagnoses represent a broad coded disease outcome, and the predominantly European exposure data limit transfer to other ancestries. The estimates concern lifelong, approximately linear variation in standardized serum measurements. They do not establish the safety of IgA-lowering medicines, severe IgA deficiency or loss of mucosal secretory IgA.

Methods

Data and variant selection

We used the complete public summary statistics and lead-variant workbook from Willis and colleagues, whose meta-analyses reached maximum sample sizes of 85,204 for IgA, 58,777 for IgG and 55,368 for IgM. Sample coverage varies by variant. Antibody measurements were transformed and standardized before analysis, so effects are expressed in those units rather than grams per liter (g/L) or percentage reductions in concentration. The contributing studies were predominantly European ancestry. [2,3]

FinnGen release 13 supplied bacterial pneumonia and pneumococcal pneumonia summary statistics. The primary endpoint combines pneumonia diagnoses attributed to pneumococci, Haemophilus bacteria and other bacteria. Both endpoints have 409,571 controls, excluding the broader influenza/pneumonia category. Counts were verified against the release-specific application programming interface for disease definitions and counts. A cohort-level audit identified no named Finnish or FinnGen cohort among the exposure studies, although participant-level overlap could not be checked. [4]

We began with the union of published lead variants, the variants representing genome-wide-significant antibody associations (P<5×10⁻⁸). Before inspecting outcome effects, we excluded chromosome X, the human leukocyte antigen region, which contains immune-system genes, on chromosome 6 at 25–35 megabases (Mb), variants involving more than a single DNA base, allele pairs whose strand orientation is ambiguous, and discovery minor-allele frequencies below 1%. We also excluded the source's extended immunoglobulin structural regions, where genotype-dependent assay binding can mimic concentration differences: chromosome 2:87,700,002–90,402,287, chromosome 14:102,000,093–106,883,703 and chromosome 22:21,026,216–23,922,208, all in the GRCh38 human reference genome coordinate system. [3]

Every variant required observed coefficients for all three antibodies. We matched GRCh38 positions and allele pairs to FinnGen and aligned effect directions. Linkage disequilibrium, the correlation between nearby variants, was estimated in 503 European participants from 1000 Genomes Phase 3, a public reference collection of genetic variation, after explicit coordinate conversion to the older GRCh37 reference genome and allele matching. We selected variants by the smallest exposure P value, retaining pairwise r²<0.001 within 10 Mb, where r² measures the squared correlation between variants. Finnish-reference sensitivities used 99 participants.

The strongest common IgG lead, rs56091027, was absent from the outcomes. We searched within 250 kilobases (kb) for proxy variants with unambiguous strand orientation and European r²≥0.8, selecting the highest-r² variant available in all five association datasets (three antibodies and two pneumonia outcomes), with coordinate order breaking ties. The selected rs61803049 had r²=0.992 in Europeans and 1 in Finns. We used its directly observed exposure and outcome coefficients and repeated pruning. Its heterogeneity annotation was inherited from the original lead. Other unavailable outcome variants were omitted, leaving 91 fitted variants in the full panel.

The six panel definitions in Table 1 were fixed before viewing the first outcome estimates. The 20% increase was likewise a prespecified research precision target. Exploratory analyses comprised robust regression, additional linkage-disequilibrium checks and EPIC-Norfolk recalibration; all six panels were retained.

Estimation and sensitivity analyses

We regressed variant log-odds coefficients for pneumonia on their three antibody coefficients without an intercept, weighting by inverse outcome variance. Standard errors allowed for more variation around the fitted model than expected from measurement error alone, with the variance multiplier bounded below by one. We exponentiated the negative IgA coefficient to express effects per unit lower IgA. Conditional-strength calculations followed Sanderson and colleagues, using ordinary-least-squares slopes relating each antibody to the others and a covariance-adjusted residual statistic divided by the number of variants minus two. [5]

The meta-analysis does not supply covariances between estimation errors for different antibody classes. We examined zero correlations and half or full EPIC-Norfolk correlations between log-transformed antibody measurements: 0.377 for IgA–IgG, 0.050 for IgA–IgM and 0.176 for IgG–IgM. These are sensitivity scenarios, not measured meta-analysis error correlations or guaranteed worst cases.

MM and median regressions followed Grant and Burgess. Median standard errors used 2,000 parametric normal draws of exposure and outcome coefficients per panel and covariance scenario, with random seed 20261102. MM standard errors were corrected so that residual scales below one could not narrow confidence intervals. Calculations used the statistical software R 4.4.3, with robustbase 0.99-7 for robust regression and quantreg 6.1 for median regression. [6]

For the full, low-heterogeneity, 34- and 24-variant panels, a separate weak-instrument diagnostic divided squared outcome residuals by their variances, including uncertainty in all exposure coefficients. We compared their sum with the 95th percentile of a chi-square distribution with one degree of freedom per variant and projected accepted coefficient combinations onto IgA by optimizing over IgG and IgM. This assumes valid independent instruments and independent exposure–outcome errors. An analytic bound excluded acceptance outside a finite coefficient sphere; differential evolution, a numerical search algorithm, with three random seeds checked for distant accepted regions inside it. Internal optimization remains numerical rather than formally certified, so these are supporting diagnostics.

Linkage-disequilibrium sensitivities relaxed European pruning to r²<0.01, required that threshold in both European and Finnish references, or added 2 Mb separation to the primary pruning. These independent-variant fits assess stability rather than supplying definitive correlated-variant inference. EPIC-Norfolk effects and standard errors were converted from log units using source standard deviations of 0.499609, 0.287184 and 0.535872 for IgA, IgG and IgM, respectively, without reselecting variants on EPIC-Norfolk significance. All analyses used public summary data.

References

  1. Liu L, et al. Genetic regulation of serum IgA levels and susceptibility to common immune, infectious, kidney, and cardio-metabolic traits. Nature Communications 13, 6859 (2022). Article.
  2. Willis TW, et al. Large-scale GWAS meta-analysis of serum antibody levels in healthy individuals reveals distinct genetic architectures. Genes & Immunity 27, 553–565 (2026). Article.
  3. Willis and colleagues. Public serum antibody GWAS summary statistics, supplementary workbook and measurement notes. Zenodo data record.
  4. FinnGen release 13. Bacterial pneumonia definition, bacterial pneumonia counts, and pneumococcal pneumonia counts.
  5. Sanderson E, Spiller W, Bowden J. Testing and correcting for weak and pleiotropic instruments in two-sample multivariable Mendelian randomization. Statistics in Medicine (2021). Methods.
  6. Grant AJ, Burgess S. Pleiotropy robust methods for multivariable Mendelian randomization. Statistics in Medicine (2021). Methods.