# Review 1

**Recommendation: minor revisions**

## What the paper claims

Two BRCA2 saturation maps measured the same single-base changes: Sahu et al. in mouse stem cells and Huang et al. in human cells. Some amino-acid substitutions can be made by two different single-base changes, which the paper calls two "spellings". The paper asks whether the second spelling, scored in the first lab, predicts whether a strong damage call on the original change repeats in the other lab. Its answer is yes. Starting from mouse cells, 41/49 strong calls repeated when the other spelling scored abnormal and 4/29 when it scored normal. Starting from human cells the counts were 43/51 and 4/19. The paper then narrows the claim honestly. In the mouse map, a *different* substitution at the same residue fails to repeat just as often, so the warning marks the residue, not the exact allele. Once a model already knows the score, the site and local assay quality, the second spelling adds little prediction. The paper also rebuilds Sahu's evidence points and classifications from the deposited tables.

The question is answered clearly, and the narrowing (a residue-level warning, not allele-specific evidence) is the most useful part of the paper.

## Rerun

I copied `analysis/`, `data/` and `run.sh` to scratch and ran the whole pipeline. It finished cleanly and matched the paper:

- Table 1 in both directions: 41/49, 4/29, 6/9, 304/546; 43/51, 4/19, 1/2, 286/410.
- One variant per substitution: 20/25 vs 4/29 and 22/29 vs 4/19. Gaps with residue-resampled intervals: 0.66 (0.44–0.85) and 0.55 (0.29–0.78).
- Depth and splice restrictions (`checks.csv`), and the medians of the other lab's raw log₂ depletion.
- Same-site controls: mouse 17/17 of 21 and 3/3 of 22; human 17/16 of 24 and 3/7 of 10. I also looked at the matches, because controls at normal-mate mouse sites are matched less closely on score (median 0.34 SD vs 0.15 SD). The pipeline's half-SD caliper check still gives 3/14 vs 12/15 for both originals and controls in mouse cells, so looser matching does not explain the result. Consider giving this one number in the text.
- Brier scores (0.172→0.141, 0.205→0.178, 0.131→0.127, 0.173→0.171) and the exon-deletion gains.
- The reconstruction: all 6,551 point assignments and classifications; 991 B / 226 P among the 1,282 uncertain or conflicting missense variants. Neither the AVENGERS nor the integrated ACMG column in the deposited tables gives the abstract's 20.4%. The paper's cautious wording ("could not establish") is right.
- The labels of the 20 flagged LP calls in the joint analysis (2 LP, 9 LB, 9 VUS, 3 of the VUS marked discordant) and the case–control coverage (5 Sahu variants, all "No evidence*"; no Huang variants).

I found no errors in the numbers.

## Main issue: the background rate is missing from the headline

Only the "None measured" row of Table 1 shows how often strong calls repeat in general. I computed it across all 633 strong Sahu missense calls that Huang also measured: 56% repeat, and Huang scores 256 of them (40%) as *normal*. In the other direction, 69% of strong Huang calls repeat in Sahu. So the comparison a reader needs is 14% (normal spelling) vs 56% (typical strong call) vs 84% (abnormal spelling), not just 14% vs 84%. The warning catches 25 of 278 nonrepeating mouse calls. That is stated, but only in the middle of the Results.

As written, the opening paragraph, the title and `so_what` let a reader conclude that strong calls without the warning are reliable. That is the wrong practical conclusion: more than four in ten strong mouse-cell missense calls fail to repeat in human cells, flagged or not. Please:

1. Give the overall rate (about 56%, or 304/546 for calls with no second spelling) in the first paragraph and in `summary`. Add one plain sentence to `so_what` saying that the two labs often disagree on strong calls in general and that the warning marks the worst subset.
2. Say plainly, once, that not repeating does not show which lab is wrong. The mouse-cell control result (whole residues whose strong mouse calls fail in human cells) fits a mouse-assay artifact, a human-assay insensitivity at those residues, or a real difference between the cell systems. Words like "confirm" and "least reproducible results" lean toward treating the human lab as the truth. Saying "repeat" consistently, or adding this one sentence, would fix that.

## Smaller points

- **Wrong denominator for opposite pairs.** "Four of 481 pairs retained an abnormal/normal split" uses the wrong base. Among pairs scored abnormal or normal in both labs, Sahu splits 35, and in Huang 4 of those keep the split in the same direction and 1 reverses it. The point ("not all discordance is noise") is better made as 4 of 35. The current figure makes the exceptions sound rarer than they are. Also, "measured in full" is unclear, since 481 counts every pair measured in both labs, intermediates included.
- **Prediction section.** The exon-deletion check gives a positive gain in 9 of 12 deletions for Sahu and 10 of 12 for Huang. "Could make either gain disappear or reverse" is true but reads as more negative than the data. For Huang, adding the synonymous-tail term made the baseline worse (0.165 → 0.173 without the spelling term). Reporting the expanded model is fine, but the paragraph could be half as long without losing the point: the added value is small and cannot be estimated from about 50 substitutions.
- **Verdict.** `numbers: partly / our-limits` and `conclusion: holds` are defensible. The classification arithmetic reproduces exactly, and the paper does not claim that Sahu's points are wrong. The `note` crams three ideas into one sentence. Make it say directly: the reconstruction holds, one abstract percentage could not be matched, and strong calls with a normal second spelling seldom repeat in the other lab, but the original conclusion does not depend on them.
- **Wording.** "Experimental segment", "tile" (in record.json) and "eligible" (for controls) need a few words of definition for readers outside the field.

## What would most improve the paper

Put the 56% background rate next to the 14% and 84% in the opening paragraph and in `so_what`, and state that nonrepetition does not say which lab is wrong. Then the take-home message is accurate: the labs disagree often on strong calls, and a normal second spelling marks a residue-level subset where disagreement is the norm.