ReproductionImaging

Six published breast cancer response scores match predictions scored in reverse

Version 2 Published 2026-11-01 DOI 10.5281/zenodo.24373483 First published 2026-10-30

Original paper Predicting breast cancer response to neoadjuvant treatment using multi-feature MRI: results from the I-SPY 2 TRIAL Li et al. (2020). npj Breast Cancer. doi:10.1038/s41523-020-00203-7
Numbers reproduced
Partly, limits of our recheck
Original conclusion
Unclear

Most selected-model scores closely reproduce, but six match outcome-dependent ROC reversal rather than fixed-direction validation; missing original code, historical labels and selection details prevent definitive attribution or a verdict on the broader conclusion.

In plain English

The original study combined MRI measurements to predict whether chemotherapy would leave no invasive breast cancer at surgery. We rebuilt its models and found that six subgroup scores closely matched the published values when the scoring rule used known outcomes to decide which way predictions should count. In the smallest subgroup, this changed a score of about 0.17 to 0.83. The high subgroup score needs clarification before it can be trusted as evidence of prediction, but missing original implementation details prevent us from establishing an error. Several other model scores reproduced.

Magnetic resonance imaging (MRI) during chemotherapy can help predict whether breast cancer will be cleared by the time of surgery. Researchers want to know whether combining several image measurements improves those predictions. A published study reported an improvement, but interpreting its scores requires knowing whether a higher predicted chance of response was always scored as meaning a better response.

In our reconstruction, six published subgroup scores closely match only when the scoring rule can reverse the meaning of predictions after seeing the outcomes of patients held out for testing. The largest discrepancy concerns a published score of 0.83 on the area under the receiver operating characteristic curve (AUC), a measure of how well predictions rank responders above nonresponders. We obtain 0.174 when higher predicted response probability means response, and 0.826 when evaluation can reverse that direction. The combined score for all patients reproduces without reversal. The subgroup results need clarification before they can serve as evidence of predictive performance.

Background

Li and colleagues studied 384 participants in I-SPY 2, a breast cancer trial of treatment before surgery. They asked whether combining MRI measurements improved prediction of pathological complete response (pCR), defined as no residual invasive cancer in the breast or axillary lymph nodes at surgery. Their 2020 analysis reported a combined-model AUC of 0.81, compared with 0.77 for functional tumor volume alone. Its results table reports combined AUCs of 0.82–0.88 for four tumor subtypes defined by receptor status. These comparisons support the paper's conclusion that multiple MRI features can improve response prediction. [1]

The measurements describe different aspects of the image. Functional tumor volume (FTV) measures contrast-enhancing tumor tissue; longest diameter (LD) measures tumor extent; sphericity (SPH) measures how closely the tumor resembles a sphere; and background parenchymal enhancement (BPE) measures contrast uptake in normal breast tissue. Hormone-receptor (HR) status and human epidermal growth factor receptor 2 (HER2) status define biologically and clinically distinct breast-cancer groups. The symbols + and − indicate positive and negative status. Triple-negative tumors lack estrogen and progesterone receptors, the hormone receptors considered here, and are HER2-negative. The authors selected combinations of baseline measurements and changes through the presurgery scan, separately for each group. The models therefore used measurements spanning treatment through the presurgery visit. [1]

AUC measures ranking. An AUC of 0.83 means that a responder receives a higher score than a nonresponder in 83% of pairs, counting ties as half. For a model predicting response probability, the intended direction is therefore fixed. Reversing the ranking changes AUC to one minus AUC. The pROC software package used in the original study calculates receiver operating characteristic curves and their areas. It can choose direction automatically by comparing the median scores of responders and nonresponders. This is useful for describing a marker with unknown direction, but choosing direction from held-out outcomes changes the prediction rule during evaluation. Its documentation warns that automatic direction biases AUC upward during resampling. [2]

Results

Six subgroup scores depend on scoring direction

The six discrepant scores approach the published values when evaluation uses automatic direction; several combined-model scores reproduce with direction fixed. We reconstructed all 25 feature sets in the published supplement, using the released MRI measurements and clinical outcomes. Each model underwent 100 repetitions of five-fold cross-validation: patients were divided into five groups, and models fitted on four groups predicted outcomes in the remaining group. Table 1 gives the six discrepancies and the four remaining combined-model comparisons.

Patient group Model Published AUC Fixed direction Automatic direction
HR−/HER2+ FTV 0.67 0.334 0.666
HR−/HER2+ SPH 0.73 0.260 0.740
HR−/HER2+ BPE 0.75 0.262 0.737
HR−/HER2+ Combined 0.83 0.174 0.826
HR+/HER2− BPE 0.66 0.346 0.654
HR+/HER2+ SPH 0.65 0.349 0.651
All patients Combined 0.81 0.807 0.807
HR+/HER2− Combined 0.83 0.831 0.831
HR+/HER2+ Combined 0.88 0.881 0.881
Triple-negative Combined 0.82 0.812 0.812

Table 1. Published scores and reconstructed mean AUCs. Each reconstruction pools held-out probabilities within a repetition, then averages AUC across 100 repetitions. Automatic direction uses the outcome-group medians in those held-out predictions. It reversed the six discrepant models in 99–100 repetitions and never reversed the four combined-model comparisons below them.

The largest discrepancy is the combined model for HR−/HER2+ disease, the smallest subgroup, with 30 patients and 20 complete responses. Its four predictors are FTV change from baseline to presurgery, baseline sphericity, early sphericity change, and early BPE change. The same predictions yield mean AUC 0.174 with fixed direction and 0.826 with automatic direction, close to the published 0.83. The agreement of the full-cohort and other combined-model scores argues against a global reversal of outcome coding.

Independent fitting confirms the largest discrepancy

A separate implementation in the R statistical computing language reproduces the reversal without using the Python implementation's predictions or divisions of patients into folds. For the HR−/HER2+ combined model, its mean pooled AUC is 0.161 with fixed direction and 0.839 with automatic direction. Averaging AUC within the test folds instead gives 0.158 and 0.843. Every fold contains four responders and two nonresponders, so variation in the proportion of responders across folds cannot explain this result.

Comparing patients scored by the same fitted model also preserves the reversal. We left out each of the 200 responder–nonresponder pairs, fitted the model on the other 28 patients, and compared the excluded pair. The resulting AUC is 0.035. Thus, the discrepancy persists when each comparison uses predictions from the same fitted model. Neither implementation produced warnings that the fitting algorithm had failed to converge; the R fits also produced no warnings about probabilities at the boundaries of zero or one.

The high automatically oriented score does not supply a direction that can simply be learned in advance. Choosing direction from training-set outcome medians, then applying it to the test fold, gives mean fold AUC 0.235 rather than 0.843. These low scores describe repeated fitting of a small dataset whose predictors had already been selected.

Automatic direction raises scores after outcome labels are shuffled

A null experiment shows how the scoring rule can increase AUC without a feature–outcome association. We shuffled the 30 patients' response labels 1,000 times, preserving the 20:10 response balance and the four selected MRI predictors. Each permutation, or reshuffling, underwent ten repetitions of five-fold validation.

Distributions of AUC under shuffled response labels, comparing fixed and automatic direction for pooled predictions and fold-average AUC.

Figure 1. Automatic direction shifts the permutation scores upward. Each distribution contains 1,000 values, each averaging ten validation repetitions. Mean pooled AUC is 0.485 with fixed direction and 0.610 with automatic direction. When direction is chosen separately within six-patient test folds, the corresponding means are 0.504 and 0.709. The dotted line marks AUC 0.5. These distributions describe the scoring rule's behavior with the selected features held fixed.

The central 95% of pooled automatic scores spans 0.517–0.788. Automatic scoring can therefore produce apparently useful rankings even after the outcome labels have been shuffled.

Interpretation

Six published subgroup AUCs closely match evaluation that permits outcome-dependent reversal, whereas the intended probability ranking gives substantially lower scores. Li and colleagues explicitly selected variables to maximize cross-validated AUC and reported using caret, a model-training software package, and pROC. They did not specify scoring direction or enough of the selection and aggregation procedure to reconstruct their implementation exactly. [1] Automatic reversal is a supported explanation for the discrepancy. If held-out outcomes determined direction, that evaluation would be wrong for validating predicted response probabilities.

The broader conclusion that combined MRI measurements improve prediction remains unresolved by this recheck. The combined score for all patients and three other subgroup combined scores closely reproduce. Evaluating the original held-out response probabilities with their meaning fixed before examining outcomes would distinguish a scoring error from differences in our reconstruction.

The missing original code, divisions into folds, historical outcome labels and complete variable-search procedure prevent us from establishing that the authors made this scoring error. Our numerical rechecks held published feature sets fixed rather than repeating selection inside validation; they are neither independent validation nor unbiased estimates of the development process's performance. The low scores do not establish an inverse biological predictor, and the permutation distributions are neither patient confidence intervals nor a test accounting for feature selection. The released outcomes differ from the publication by one triple-negative response, outside the subgroup with the largest discrepancy. We performed no external validation, and models using measurements through presurgery cannot establish the benefit of MRI-guided treatment changes earlier in treatment.

Methods

We joined the public I-SPY 2 multi-feature MRI workbook to its clinical workbook by unique patient identifiers. All 384 MRI cases matched, all supplied features were complete, and recomputed percentage changes agreed with the released values. The clinical release contains 113 complete responses versus the publication's 114. Subgroup sizes match the publication: 162 HR+/HER2−, 60 HR+/HER2+, 30 HR−/HER2+, and 132 triple-negative patients. Their released response counts are 24, 19, 20 and 50. We used these released labels without alteration. [1,3]

For each of the five cohorts, comprising all patients and the four subgroups, we transcribed the four single-feature models and combined model from Supplementary Table 1. Baseline values and percentage changes from baseline at early, mid-treatment and presurgery visits entered exactly as specified. Full-cohort models also included categorical receptor subtype. We fitted unpenalized logistic regressions, models of response probability without a penalty on coefficient size, with intercepts using the Python machine-learning package scikit-learn 1.9.1. Predictors were standardized within each training fold. One hundred shuffled five-fold partitions, stratified to preserve the response balance, used seeds 20261030 through 20261129, shared across feature sets within each cohort.

We calculated fixed-direction AUC from predicted pCR probabilities, with pCR coded as 1. Automatic direction reversed the score when the median prediction among nonresponders exceeded that among responders. This median rule need not select the larger of AUC and its complement. Primary results average the pooled held-out AUCs across repetitions.

The independent analysis used R 4.4.3 and pROC 1.19.1, binomial generalized linear models for the binary response outcome, and independently sampled stratified partitions with seed 20261031. Its predictor scaling used all patients; this changes the units and origin of predictors in an unpenalized regression and leaves predictions unchanged. We evaluated pooled AUC, mean within-fold AUC, training-only direction choice and leave-pair-out ranking. The permutation analysis used seed 20261101, kept predictors fixed, and reshuffled labels before creating stratified folds. No permutations were discarded. Permutation fits generated 406 boundary-probability warnings and no nonconvergence warnings. We report descriptive numerical comparisons without post-selection significance tests or population confidence intervals.

References

  1. Li W, et al. Predicting breast cancer response to neoadjuvant treatment using multi-feature MRI: results from the I-SPY 2 TRIAL. npj Breast Cancer (2020). Article and supplementary tables.
  2. pROC. Build a ROC curve. Reference documentation, including direction selection and the resampling warning.
  3. The Cancer Imaging Archive. I-SPY 2. Public clinical and multi-feature MRI data.