# Cen X-3's X-ray pulse pattern differs when its rotation speeds up or slows down

Gas falling onto a neutron star changes both its rotation and the X-rays it emits. Astronomers want to know whether a switch between speeding up and slowing down also changes the pattern of X-rays seen during each rotation. Brightness changes make that connection difficult to isolate. In the neutron star Cen X-3, we find a repeated difference in the lower-energy X-ray pulse pattern after accounting for measured brightness. Across 230 intervals with securely measured rotation trends, the phase of its two-cycle-per-rotation component is lower by 0.120 radians when the star speeds up, measured relative to higher-energy X-rays. The difference persists when rotation trends and pulse patterns are measured separately and when episodes of similar brightness and date are compared.

## Background

Cen X-3 is a neutron star that accretes gas from a companion and rotates approximately once every 4.8 seconds. Its X-ray brightness varies through each rotation, producing a pulse profile. Changes in rotation frequency measure the sign of the net torque, or turning force: increasing frequency defines spin-up and decreasing frequency defines spin-down. Pulse shape offers a second view of the accretion flow, through the emitting regions and the material that absorbs or scatters their radiation. The system also has a roughly 2.1-day binary orbit, which must be distinguished from its much shorter rotation period. [Malacaria et al. (2020)](https://arxiv.org/html/2004.00051)

Torque-dependent changes are already known on the orbital timescale. Liao and Liu found different patterns of X-ray brightness around the orbit in spin-up and spin-down states at similar observed flux, or received brightness. Observations aimed directly at the source also show that the rotational pulse profile varies with photon energy and time. These results motivate a more specific question: does the relative rotational waveform in different energy bands retain a torque-state association across many episodes after brightness adjustment? [Liao and Liu (2024)](https://arxiv.org/abs/2401.09197), [Tamba et al. (2023)](https://arxiv.org/abs/2212.10782), [Liu and Wang (2023)](https://arxiv.org/abs/2304.13279)

We describe the waveform through its harmonics. The fundamental is a sinusoidal component with one cycle per rotation; the second harmonic has two. Each component has an amplitude and a phase specifying its position within the rotation. Comparing the same harmonic between energy bands measures their relative waveform structure without requiring an absolute rotational phase origin. Our main measurement is the second-harmonic phase in the nominal 8–12 kiloelectronvolt (keV) band relative to the 12–25 keV reference band. These bands group photons by energy; “soft” means lower energy and “hard” means higher energy. We express phase as an angle in radians (rad). A harmonic-phase difference is a shape measurement, rather than a whole-pulse arrival-time delay.

## Results

### The soft phase difference survives brightness adjustment

The soft second-harmonic phase is lower during spin-up under each of the principal brightness and measurement controls. We analyzed 2,516 pulse measurements from the public pulsar history of the Fermi satellite's Gamma-ray Burst Monitor (GBM). Each measurement combines observations over an interval called an integration. Short observations, or snapshots, from the Swift satellite's Burst Alert Telescope (BAT) provide a separate measure of brightness. We grouped the integrations into fixed 20-day blocks and classified blocks with well-measured rotation trends as secure. These provide 128 secure spin-up and 102 secure spin-down measurements, containing 1,877 usable waveform integrations. The secure blocks span Modified Julian Dates (MJD, an astronomical day count) 54694–61066, approximately 17 years. The source products are available from the [GBM pulsar monitor](https://gammaray.nsstc.nasa.gov/gbm/science/pulsars/lightcurves/cenx3.html) and [BAT transient monitor](https://swift.gsfc.nasa.gov/results/transients/CenX-3/).

Spin-up blocks are brighter on average. Nevertheless, adjusting for BAT brightness does not remove the phase difference (Table 1). Our full model also accounts for pulsed amplitude, which measures the strength of the rotating brightness variation, integration duration and year. It gives a spin-up minus spin-down difference of −0.120 rad. Repeatedly resampling whole 180-day segments and refitting the model gives a conditional 95% bootstrap interval of [−0.163, −0.080] rad. Within this detected sample and adjustment model, the estimated shift remains negative throughout that interval.

| Comparison | Blocks | Up-minus-down difference (rad) |
|---|---:|---:|
| Unadjusted | 230 | -0.135 |
| BAT brightness adjustment | 230 | -0.145 |
| Full adjustment | 230 | -0.120 |
| Disjoint timing and waveform integrations | 207 | -0.134 |
| Equal-weight integration phases | 230 | -0.146 |
| Pulsed-amplitude signal-to-noise >40 | 121 | -0.108 |

Table 1. Soft second-harmonic phase differences relative to 12–25 keV. Full adjustment includes terms through the third power of log BAT brightness, through the second power of log pulsed amplitude, mean integration duration and a separate baseline for each year. The first two rows use only the stated adjustment. All remaining rows use the full model. The analysis includes individual harmonics regardless of their statistical significance. The final row requires a high ratio of total pulsed amplitude to its measurement error (signal-to-noise), while keeping the same rotation-trend labels.

Separating timing and waveform measurements retains the difference. Fitting rotation trends on alternate integrations and measuring profiles on the intervening integrations leaves 207 secure blocks and gives −0.134 rad, with bootstrap interval [−0.211, −0.071] rad. Shared measurement noise within the same integration therefore cannot by itself explain the result. The main estimator weights each integration by the product of the two bands' harmonic amplitudes, the magnitude of their harmonic cross-power. Giving each integration's phase equal weight also retains a negative contrast (−0.146 rad).

### The difference recurs across episodes

The association is distributed across the history rather than concentrated in one episode. We grouped consecutive secure blocks of the same torque sign into 92 episodes defined by the timing blocks, of which 60 contain at least two blocks. Matching whole spin-up and spin-down episodes by brightness and date without reuse yields 24 pairs. The soft contrast is negative in 23 pairs, with mean −0.155 rad (Figure 1). Deleting any one episode leaves the adjusted difference between −0.126 and −0.110 rad. Using disjoint timing and waveform integrations gives 12 negative contrasts among 14 matched pairs, averaging −0.152 rad.

![Matched episode contrasts and adjusted cross-energy phase estimates](results/episode_diagnostics.png)

Figure 1. A: Soft second-harmonic contrasts for matched episode pairs, plotted at the mean of their two dates. B: Fully adjusted phase differences relative to 12–25 keV, with normal-approximation 95% intervals using standard errors that allow measurements within each 180-day segment to be correlated. These intervals differ from the percentile bootstrap intervals quoted in the text and do not adjust for the many comparisons tested. “Equal phase weights” represents each phase by a unit-length vector and averages those vectors, giving each integration equal weight. The hard band is 25–50 keV.

The contrasts recur in many parts of the record and agree with the brightness-adjusted estimate. Matched spin-up episodes remain somewhat brighter, and different pairs can share calendar conditions, so the 23-of-24 sign count is descriptive rather than a binomial significance test.

### Detection cuts and other harmonics narrow the finding

The soft difference persists well above the overall pulse-detection threshold, while the corresponding hard-band result depends more strongly on which measurements are included. Requiring total pulsed-amplitude signal-to-noise above 40 leaves 121 blocks and a soft contrast of −0.108 rad. The older GBM history contains 666 nondetections, but all their harmonic coefficients are zero-filled. They represent unavailable waveform measurements. Among rows in classifiable timing blocks, detection fractions are 90.1% during spin-down and 91.5% during spin-up. Similar detection fractions and the bright-source check argue against an effect confined to barely detected pulses.

Without individual-harmonic cuts, the hard second-harmonic contrast is +0.092 rad with a clustered standard error of 0.056 rad; brightness and signal-to-noise restrictions change it substantially. The soft fundamental contrast is smaller, −0.009 rad with standard error 0.008 rad, and becomes modestly negative under bright restrictions. The evidence is strongest for the soft second harmonic; the hard-band estimate is sensitive to selection and the fundamental can also shift.

### Accounting for changes over time

Measurements close in time may share variations that the model does not explain. Allowing these residual variations to move together over long intervals retains evidence for the soft contrast. We tested a zero torque-state coefficient by fitting the brightness and time controls alone, reversing the signs of entire segments of residuals, and refitting the full model. Table 2 reports how often these sign reversals produce a torque-state effect at least as large in absolute value as the observed effect, after dividing each estimate by its segment-adjusted standard error. These proportions are two-sided tail fractions.

| Segment length | Segments | All integrations | Disjoint integrations |
|---|---:|---:|---:|
| 180 days | 36 | 0.000020 | 0.000180 |
| 360 days | 18 | 0.000015 | 0.000130 |
| 720 days | 9 | 0.003906 | 0.007812 |

Table 2. Conditional tail fractions from the restricted wild-cluster bootstrap. The 180-day test uses 49,999 random sign patterns and an add-one correction; the all-integration result has no simulated exceedances. The 360- and 720-day tests enumerate all 262,144 and 512 sign patterns. The all-integration 720-day fraction, 2/512, is the two-sided enumeration floor. These are approximate fitted-residual tests assuming independent, sign-symmetric errors between segments.

The analysis covers 45 sources, with 405 brightness-comparison combinations and 1,080 shape-comparison combinations; 93 and 131, respectively, meet the coverage requirements. These comparisons use 20-, 60- and 180-day timescales. The Cen X-3 comparisons include opposite-sign soft and hard shape associations, 180 cross-energy phase combinations, eight matching variants, 24 checks of brightness around the orbit and 18 local-brightness model combinations, as well as the analysis without individual-harmonic cuts reported here. This breadth of testing matters when interpreting the conditional tail fractions in Table 2.

## Interpretation

Blurring that affects both energy bands equally cannot shift the relative harmonic phase of a fixed waveform. A harmonic can be represented by a complex coefficient that encodes its amplitude and phase. Multiplying one band's coefficient by the complex conjugate of the other gives a cross-product whose angle is their phase difference. If a shared complex factor multiplies both bands at a given harmonic, their cross-product is multiplied by a positive real number, leaving its angle unchanged. This removes a common phase-origin error or common attenuation as a sufficient explanation at the individual-integration level.

Pooling integrations allows a subtler alternative. Attenuation, or weakening of the signal, can change the weights assigned to different intrinsic relative phases. We tested a restricted version of this explanation by fitting a smooth phase model without a torque-state term to brightness, pulsed amplitude, duration and year, retaining noise-corrected observed amplitudes, and adding Gaussian coefficient noise. Across 1,000 simulations, the adjusted contrasts had central 95% range [−0.031, +0.038] rad, compared with the observed −0.120 rad. That fitted mixing-and-noise model does not reproduce the contrast. Its range describes this particular simulation model.

The remaining ambiguity concerns what reshapes the observed signal. GBM combines detector measurements separately by energy channel, accounting for how detector sensitivity changes with time and assuming a distribution of photon energies. We infer that integrations with the same start and end times can still weight observations differently across energy bands. The released histories contain aggregate harmonic coefficients and errors, but neither the observing weights for each detector and energy band nor the correlations between errors in different bands needed to reconstruct that effect. [Finger et al. (2009)](https://arxiv.org/html/0912.3847)

The repeated soft waveform difference links the detected X-ray pattern to the star's rotation trend after adjustment for measured brightness. Intrinsic emission changes, energy-dependent absorption or scattering, and energy-dependent sampling of a variable profile remain competing explanations. An independently acquired comparison classified by rotation trend, with controlled energy-dependent observing weights, would most directly distinguish them.

The result applies to GBM-detected intervals; similar detection fractions do not establish that missing waveforms are random. BAT brightness measures observed hard X-rays rather than total intrinsic luminosity. The conditional tests have no independent confirmation sample and do not account for choosing associations from the many comparisons above, so they are not search-adjusted detection significances. The mixing-and-noise simulation also omits intrinsically correlated phase changes over time, detection selection and correlated noise between energy bands.

## Methods

### Measurements and torque labels

We used fixed copies of the public GBM detected and older histories containing 2,516 and 3,182 rows, respectively, and 89,729 BAT snapshots. The detected history is identical to the detected subset of the older history, so the two products are not independent measurements. For BAT, we retained finite rates, positive errors and durations, and zero quality flags. We assigned snapshot midpoints to each GBM interval and averaged rates with snapshot duration as weight, requiring at least three snapshots. We excluded eclipses, when the companion blocks the neutron star, and their margins by retaining orbital phases between 0.15 and 0.85, using the orbital timing model supplied with the GBM data. Its quadratic time dependence accounts for the changing orbital period. Waveform integrations required positive BAT rate and pulsed amplitude.

Twenty-day timing bins start at MJD 54680. Within each bin, we fit the orbit-corrected GBM rotation frequency against time by inverse-variance weighted least squares, requiring at least three timing measurements spanning eight days. When the reduced chi-squared, a measure of scatter relative to the stated measurement errors, exceeded one, we inflated slope errors by its square root. A secure label required an absolute slope greater than twice its error and at least two usable waveform integrations. There were 272 usable bins, of which 230 received secure labels. In the disjoint analysis, alternate rows within each bin supplied timing and the intervening rows supplied waveforms, with the same eligibility rules.

### Waveform estimator and adjustment

For integration \(i\), band \(E\) and harmonic \(k\), let \(z_{E,k,i}\) be the complex coefficient formed from the released real and imaginary entries. In block \(b\), we measured

\[
\theta_{k,b}=\arg\!\left[\sum_{i\in b}z_{E,k,i}z^*_{12\text{–}25,k,i}\right].
\]

Here, the asterisk denotes complex conjugation and arg extracts the angle of the summed cross-products. The ordering of the released coefficient entries determines the sign. Stronger cross-products carry greater weight. The equal-phase-weight check instead averages unit vectors with the individual cross-product angles. Secure soft second-harmonic block angles range from −0.540 to +0.928 rad, away from ±π, where the angle wraps from one end of its range to the other. This permits an ordinary linear phase regression.

We fit unweighted block-level least squares with an intercept, spin-up indicator, terms through the third power of centered log BAT rate, through the second power of centered log pulsed amplitude, centered mean integration duration, and indicators for successive 365.25-day years anchored at MJD 54680. Block brightness, amplitude and duration are arithmetic means across usable waveform integrations. Centering subtracts each variable's mean before fitting. The spin-up indicator coefficient is the reported up-minus-down contrast. Clustered standard errors use calendar segments anchored at the same date and the finite-sample factor \(G/(G-1)\times(N-1)/(N-K)\), where \(G\) is the number of segments, \(N\) the number of blocks and \(K\) the number of independent model terms (the design rank). Percentile intervals resample 180-day segments with replacement in 2,000 draws, refitting all coefficients.

### Episodes and conditional simulations

An episode joins successive secure same-sign blocks across at most one missing or unclassified grid bin. A sign change or a separation exceeding two grid bins starts a new episode. Matching uses episodes with at least two secure blocks, their mean BAT rates and mean dates. We allow absolute log flux ratios below 0.2 and date differences below 1,000 days. A minimum-cost one-to-one assignment minimizes the sum of squared differences scaled by those limits; forbidden pairs receive a prohibitive cost and are discarded. Episode contrasts subtract their mean block phases.

For the temporal test, we first fit a regression containing only the brightness, amplitude, duration and year controls, without the torque-state term. We then multiply all residuals within each calendar segment by a shared random sign, add them to the fitted values, and refit the full regression and clustered standard error. Exceedances compare the absolute torque-state coefficients divided by their clustered standard errors. Complete sign enumeration still gives an approximate bootstrap because the residuals are estimated.

For the coefficient-noise diagnostic, we represent integration phases as unit-length complex vectors, fit them using the same controls without a torque-state term, and take the angle of each prediction. Band amplitudes are corrected by subtracting twice the squared component error from squared magnitude, truncated at zero. We retain the observed reference phase, impose the predicted relative phase, add independent Gaussian real and imaginary errors, and rebuild the block estimator and regression. The per-component error convention follows the harmonic-variance description in [Malacaria et al. (2020)](https://arxiv.org/html/2004.00051).

## References

Finger, M. H., et al. (2009). *Long-term Monitoring of Accreting Pulsars with Fermi GBM*. [arXiv:0912.3847](https://arxiv.org/abs/0912.3847).

Liao, Z., and Liu, J. (2024). *Torque-dependent orbital modulation of X-ray pulsar Cen X-3*. Monthly Notices of the Royal Astronomical Society: Letters, 529, L130–L134. [doi:10.1093/mnrasl/slae009](https://doi.org/10.1093/mnrasl/slae009).

Liu, Q., and Wang, W. (2023). *Measurements of spin and orbital parameters in Cen X-3 by Insight-HXMT*. Journal of High Energy Astrophysics, 38, 32–40. [arXiv:2304.13279](https://arxiv.org/abs/2304.13279).

Malacaria, C., et al. (2020). *The Ups and Downs of Accreting X-ray Pulsars: Decade-long observations with the Fermi Gamma-Ray Burst Monitor*. [arXiv:2004.00051](https://arxiv.org/abs/2004.00051).

Tamba, T., et al. (2023). *Orbital- and spin-phase variability in the X-ray emission from the accreting pulsar Cen X-3*. [arXiv:2212.10782](https://arxiv.org/abs/2212.10782).