# Sweat chloride fell more than registry data predicted on triple therapy for 41 of 49 rare cystic fibrosis genotypes

For cystic fibrosis mutations too rare for separate trials, researchers can test a drug in cells to see how much chloride transport it restores. In the sweat gland, better transport lets the body reclaim more chloride before sweat reaches the skin. The harder question is what that gain means in a patient. Inherited differences in chloride transport provide one possible guide: people with more working channels tend to have less chloride in their sweat. We used that relationship to predict the fall in sweat chloride on triple therapy. The fall exceeded the prediction for 41 of 49 rare genotypes whose cell measurements were within the range used to fit the relationship. Across all 49, the median excess was 19.6 millimoles per litre (mmol/L).

## How cell measurements give a prediction

The cystic fibrosis transmembrane conductance regulator (CFTR) gene encodes a chloride channel. In the sweat duct, too little CFTR activity leaves more chloride in sweat. A fall in sweat chloride during treatment is a direct sign that the drug is acting on its target. Two drugs, elexacaftor and tezacaftor, help susceptible forms of the channel reach the cell surface. A third, ivacaftor, helps the channel open. We refer to the combination as ETI.

McCague and colleagues found that each doubling of estimated inherited channel activity corresponded to a decrease in sweat chloride. Responses to CFTR drugs were broadly consistent with that relationship in trials of people with the common F508del mutation or with mutations that impair channel opening, analysed as a group [1]. We tested whether activity measured in cells could predict the size of the fall for rare genotypes without F508del. Here a genotype is the pair of CFTR gene copies, or alleles, that a person carries.

We combined two sources to estimate the relationship. Bihler and colleagues measured how readily chloride passed through channels in cells expressing each of 655 CFTR variants, with and without ETI [2]. We estimated a genotype’s activity by averaging its two alleles’ activities, expressed as percentages of normal channel activity. The Clinical and Functional Translation of CFTR (CFTR2) database supplied the mean sweat chloride for each genotype [3]. We fitted a line relating these registry means to doublings of untreated cell activity. We chose an exploratory range of 0.85% to 50% of normal activity to avoid basing the fit on nearly zero readings.

Across the 169 registry genotypes in that range, sweat chloride was 8.0 mmol/L lower for each doubling of activity (Figure 1A). To predict the fall on ETI, we multiplied that decrease by the number of doublings between a genotype’s untreated and treated cell activities. A drug that raises activity from 2% to 8% gives the same predicted fall as one that raises it from 4% to 16%: about 16 mmol/L for two doublings.

## Sweat chloride before and after treatment

A French compassionate-use programme reported sweat chloride before treatment and after 4–6 weeks of ETI [4]. For each person, we subtracted the on-treatment value from the pretreatment value. We then took the median of those paired falls for each genotype. Both cell activity estimates were in the fitted range for 49 genotypes with paired tests (61 people; Figure 1B).

Across these genotypes, the median predicted fall was 18.7 mmol/L and the median observed fall was 39.5 mmol/L. We compared the two falls within each genotype to calculate the excess: 41 had a positive excess, and the median excess was 19.6 mmol/L. Genotypes with larger predicted falls tended to have larger observed falls (Spearman rank correlation 0.49). In a comparison group of 39 programme participants whose alleles were both expected to produce little or no functional channel protein, the median paired fall was 1.0 mmol/L. A large fall was therefore not common to all groups tested twice.

![Historical sweat chloride versus cell activity and observed versus predicted falls in the French programme](results/activity_and_fall.png)

Figure 1. Each point represents one genotype. Panel A shows registry mean sweat chloride at untreated cell activity (dots) and French median sweat chloride at treated cell activity (triangles). The line uses only the registry means. Equal distances on the horizontal axis represent doublings of activity. Panel B shows the paired falls for all 92 French genotypes with positive activity estimates before and after ETI. Above the dashed line, sweat chloride fell more than predicted; a negative fall means sweat chloride rose. Circles have both activity estimates inside the fitted range. Triangles start below it; crosses have at least one estimate above it.

## Low sweat chloride values in the registry

The registry line came closer to the French sweat chloride values before treatment than after it. The median difference between observed and predicted sweat chloride was −4.7 mmol/L before treatment and −30.5 mmol/L on ETI. Even at 50% activity, the top of the fitted range, the line predicted 54.8 mmol/L. Only one of the 169 registry genotype means was below 40 mmol/L, and the lowest was 39 mmol/L. On ETI, 30 of 49 genotype medians were below 40 mmol/L and 24 were below 30 mmol/L.

Table 1. Sweat chloride by cell activity, using untreated activity for registry genotypes and treated activity for French genotypes. Sweat chloride values are medians across genotypes (mmol/L). Endpoint error is observed minus predicted sweat chloride on ETI; excess fall is observed minus predicted paired fall. We calculated each difference within genotype before taking the median.

| Activity (% of normal) | Registry genotypes | Registry sweat chloride | Treated genotypes | On-ETI sweat chloride | Endpoint error | Excess fall |
|---|---:|---:|---:|---:|---:|---:|
| 0.85 to <4 | 88 | 99.0 | 2 | 73.0 | −14.3 | 13.0 |
| 4 to <16 | 63 | 77.0 | 20 | 60.0 | −19.9 | 17.0 |
| 16 to 50 | 18 | 57.5 | 27 | 25.0 | −36.6 | 22.9 |

The largest error occurred at the highest activities (Table 1). More than half the treated genotypes fell in this band, compared with only 18 registry genotypes. Who receives a diagnosis could help explain the gap. In someone with symptoms or a positive newborn screen, sweat chloride of at least 60 mmol/L supports a [diagnosis of cystic fibrosis](https://www.cff.org/medical-professionals/cf-diagnosis-clinical-care-guidelines). People who retain some channel activity and have lower sweat chloride may therefore be underrepresented in the registry. The French participants had already received a diagnosis before their on-treatment test. With so few registry values at high activity, it is difficult to tell whether sweat chloride falls more steeply there than the line predicts. Changing the curve’s shape cannot supply the missing low values.

## Predicting the fall from French pretreatment measurements

The French programme offered another way to estimate how sweat chloride varies with inherited activity. At 16–50% untreated activity, four of its eight genotype medians were below 40 mmol/L, and the median across all eight was 48.5 mmol/L. We compared predictions based on the registry with predictions based on the French pretreatment measurements. For each source we used both a fitted line and a method that drew only on genotypes with nearby activities. For example, to predict sweat chloride at 8% treated activity, we looked for other genotypes with roughly 8% *untreated* activity. We excluded genotypes sharing a measured allele with the genotype being tested, whether fitting a line or looking for nearby activities.

For 39 of the 49 treated genotypes, both sources had enough comparators near both the untreated and the treated activity. Using these same genotypes throughout, we could see how much the prediction changed with the choice of reference and method (Table 2).

Table 2. Median sweat chloride falls (mmol/L) for the same 39 genotypes (49 people). A log-linear fit estimates the change per doubling of activity. The nearby-activities method uses the median sweat chloride of genotypes within half a doubling of each activity estimate. Excess is the median of the within-genotype differences.

| Reference | Prediction method | Predicted fall | Observed fall | Excess fall |
|---|---|---:|---:|---:|
| Historical registry | Log-linear fit | 17.4 | 38.0 | 19.6 |
| Historical registry | Nearby activities | 23.0 | 38.0 | 15.0 |
| French pretreatment | Log-linear fit | 24.5 | 38.0 | 12.5 |
| French pretreatment | Nearby activities | 31.0 | 38.0 | 6.5 |

Using nearby French activities gave the smallest median excess, 6.5 mmol/L. Even then, sweat chloride fell more than predicted for 29 of 39 genotypes. Several predictions depended on the same few comparators. Above 22% treated activity, only seven genotypes had enough nearby French comparators, four to seven each. All seven used the same five people carrying the variant D1152H. Their genotypes, written as pairs of alleles, were D1152H/G85E, D1152H/W1282X and D1152H/N1303K, with pretreatment medians of 23, 38 and 59 mmol/L, respectively. All seven also used L997F/N1303K (15 mmol/L). Ten other genotypes above 22% treated activity had fewer than three comparators.

Table 3. Effect of removing the three D1152H genotypes from the French reference. Each row includes only test genotypes for which the method gave a prediction both before and after removal. Values are median excess falls (mmol/L); counts in parentheses are genotypes whose fall exceeded prediction.

| Prediction method | Genotypes supported both ways | With D1152H | Without D1152H |
|---|---:|---:|---:|
| Within half a doubling | 34 | 9.5 (26) | 22.3 (27) |
| Within one doubling | 39 | 12.0 (29) | 20.0 (31) |
| Log-linear fit | 49 | 12.5 (37) | 14.3 (38) |

Removing D1152H changed the half-doubling comparison more than removing any other single reference allele. Five of the original 39 genotypes had too few comparators left to predict their falls. Among the remaining 34, the median excess more than doubled (Table 3). The fitted line was less sensitive to D1152H. With the full French reference, requiring untreated comparators on both sides of each activity estimate gave a median excess of 13.5 mmol/L across 33 genotypes.

## Sensitivity to the starting activity

Below the fitted range, even small gains from a near-zero starting value could amount to several doublings. For 29 genotypes starting below 0.85%, the median predicted fall was 25.2 mmol/L, but the median observed fall was 8.0 mmol/L. The median excess remained negative (−12.4 mmol/L) after we excluded the variant N1303K, which occurred in 35 of the 57 people in this group. Allowing the registry curve to flatten at low activity rather than extending the straight line still gave opposite median excesses inside the range (+20.6 mmol/L) and below it (−13.1 mmol/L). Across all 92 genotypes in Figure 1B, the rank correlation between predicted and observed falls was only 0.13.

We varied the cell measurements within their reported uncertainty, chose the genotypes in range again and refitted the registry line. The middle 95% of simulated median excesses lay between 13.2 and 27.3 mmol/L: the typical in-range fall still exceeded the prediction across that interval.

A second experiment showed how strongly a new starting measurement could affect which genotypes qualified. Bihler and colleagues remeasured untreated conductance for 145 variants [5]. Of 13 originally in-range genotypes with new readings for every measured allele, only three remained in range. The untreated estimate for G85E fell from 2.32% to 0.052% of normal, moving all five people with G85E on both copies below the lower cutoff.

Replacing every available starting measurement left 38 genotypes in range; 26 had no new reading. Among the 12 with at least one updated allele, 10 still exceeded the refitted prediction (median excess 23.0 mmol/L across the 12). Selecting genotypes above a cutoff favours overestimates near that cutoff. An inflated starting value reduces the predicted number of doublings and makes the observed fall look larger by comparison.

## Interpretation

Within the fitted range, larger gains in cell activity tended to accompany larger sweat chloride falls. Both the registry and French pretreatment scales underestimated the typical fall, but neither provides a reliable correction for a new genotype. Few registry genotypes had sweat chloride as low as the values reached on ETI, and the closest French matches at high activity depended on a handful of genotypes. Below the fitted range, near-zero starting values inflated the predicted gains enough to reverse the direction of the typical error.

Neither cohort measured channel activity in the sweat gland, and membership in the fitted range depended on a noisy starting measurement. Registry treatment histories were unavailable. Registry values were means, whereas 42 of 49 French genotypes represented one person. These data cannot separate the contributions of diagnostic selection, assay error and a difference between inherited and drug-restored activity. A separate ETI trial, Study 124, found mean falls of 21 to 44 mmol/L across five groups defined by the mutation that qualified participants for the trial [6]. Without each participant’s other allele, those responses cannot independently test the genotype predictions.

## Methods

### Cell activity

We used the 655 primary variant entries in Table S1 of Bihler et al. [2]. Each variant was expressed in Fischer rat thyroid cells. For untreated activity, the experimenters measured chloride conductance after stimulating the cells with forskolin, using the vehicle (drug carrier) alone in place of ETI. For treated activity, they measured total conductance after pretreatment with elexacaftor and tezacaftor, forskolin stimulation and acute addition of ivacaftor. Both measurements were expressed relative to the forskolin-stimulated control with normal (wild-type) CFTR.

We matched allele names across sources. When several substitutions occurred on the same gene copy, we required the entire allele to match. We assigned zero activity with and without ETI to 16 alleles with premature stops, frameshifts, a deletion or disruption of a canonical splice site. These changes are expected to leave little or no functional protein for ETI to act on; zero is a modelling assumption. The alleles were G542X, R553X, W1282X, R1162X, E1104X, Y122X, W846X, 2183AA>G, 1078delT, 3659delC, 394delTT, CFTRdele2-3, 1717-1G>A, 621+1G>T, 711+1G>T and 3120+1G>A. Other unmeasured alleles were left missing.

### Registry fit and French treatment cohort

Of 1,885 genotype-specific sweat chloride records in the public CFTR2 extract [3], 369 reported a numeric mean and 216 allowed assignment of both alleles’ activities. We left missing genotype means missing rather than substituting the overall population mean. An ordinary least squares fit gave each of the 169 in-range genotypes equal weight. The fitted mean sweat chloride was 100.01 − 8.016 × log₂(activity), with activity expressed as a percentage of normal. We applied the numerical limits used by McCague et al. to the *average* of the two alleles’ activities. They applied those limits to the *sum*, equivalent to 0.425–25% on the average scale. Neither interval is a detection limit. For the curve that could flatten at low activity, we fitted nonincreasing least squares to all 216 genotypes, including zeros. We interpolated between fitted values and held the end values constant beyond the data.

We screened all 479 treated participants without F508del in the French programme described by Burgel et al. (supplementary Tables S2–S5 [4]), including both responders and nonresponders. The programme had denied treatment to 37 other applicants, so it was not a random sample of genotypes. We excluded the 36 people already taking ivacaftor when they started ETI. We could assign both untreated and treated activities for 178 of the remaining 443 people. Of these, 137 had positive activity in both conditions and 135 of those had paired sweat tests. Of 62 with both activities in range, 61 had paired tests. For each genotype we subtracted the predicted fall from the median within-person fall. Among the 14 in-range genotypes with two distinct measured alleles and no assumed zeros, the median excess was 21.7 mmol/L and 12 exceeded prediction.

### Reference comparisons and measurement uncertainty

The French pretreatment reference included 63 genotypes with an assignable in-range starting activity. We used each genotype’s median pretreatment sweat chloride whether or not paired tests were available. For nearby-activity predictions, we excluded genotypes sharing a measured allele with the test genotype. We required at least three reference genotypes within half a doubling of the target activity and predicted sweat chloride at that activity from their median. For the two-sided check we required at least two genotypes on each side within one doubling and interpolated between the two sides’ medians on the log-activity scale. For each test genotype the log-linear fits in Table 2 used all in-range reference genotypes remaining after the same shared-allele exclusion. To measure the influence of each French reference allele, we removed every reference genotype carrying it and repeated the predictions, comparing only test genotypes supported both ways.

In 3,000 simulations we drew each allele’s activity from a normal distribution with its measured mean and reported standard error. We set negative draws to zero and used the same draw wherever that allele occurred. We drew untreated and treated activities independently; imposing a correlation of 0.8 gave a similar spread in the median excess (13.3–26.4 mmol/L). These ranges describe the effect of reported assay precision rather than sampling uncertainty in treatment outcomes. For the comparison with the later experiment, we replaced only the vehicle measurements available in both experiments, updating both reference and treatment genotypes before repeating range selection and fitting.

### Trial comparison

We used Table 12 of the European Medicines Agency assessment of Study 124 [6]. We selected mutation groups with at least five sweat measurements, unflagged assay estimates and activities that would be in range if the qualifying allele were paired with a zero-function allele. The qualifying alleles were G85E, R347P, L206W, A455E and R347H. We report the range of mean falls among participants receiving ETI in these groups, without pooling groups that may overlap.

## References

1. McCague AF et al. [Correlating cystic fibrosis transmembrane conductance regulator function with clinical features to inform precision treatment of cystic fibrosis](https://pmc.ncbi.nlm.nih.gov/articles/PMC6515867/). *American Journal of Respiratory and Critical Care Medicine* (2019).
2. Bihler H et al. [In vitro modulator responsiveness of 655 CFTR variants found in people with cystic fibrosis](https://doi.org/10.1016/j.jcf.2024.02.006). *Journal of Cystic Fibrosis* (2024). [Table S1](https://ars.els-cdn.com/content/image/1-s2.0-S1569199324000213-mmc3.xlsx).
3. Clinical and Functional Translation of CFTR (CFTR2). [Public extract of genotype-specific phenotype summaries archived by E. Drysdale](https://github.com/ErikinBC/cftr2_esmfold/blob/28fecd343c6bc1201fb3ad7a3c83488e2e3ab522/data/cftr2_comb.csv).
4. Burgel P-R et al. [The expanded French compassionate programme for elexacaftor–tezacaftor–ivacaftor use in people with cystic fibrosis without a F508del CFTR variant](https://doi.org/10.1016/S2213-2600(24)00208-X). *Lancet Respiratory Medicine* (2024). [Participant tables](https://ars.els-cdn.com/content/image/1-s2.0-S221326002400208X-mmc1.pdf).
5. Bihler H et al. [In vitro responsiveness of 417 CFTR variants to vanzacaftor/tezacaftor/ivacaftor](https://doi.org/10.1016/j.jcf.2026.08.010). *Journal of Cystic Fibrosis* (2026).
6. European Medicines Agency. [Assessment report on the CFTR modulator indication extension](https://www.ema.europa.eu/en/documents/variation-report/kalydeco-h-c-002494-ws-2551-epar-assessment-report-variation_en.pdf). Study 124, Table 12.