One fast radio burst’s tail shortens more steeply at higher frequencies under three pulse models
Why it matters
Astronomers use the fading tails of brief radio flashes to study the material their signals pass through. For one flash, the fading rate changes across radio frequencies in a way that a single scaling rule misses, even after allowing several pulse shapes. That gives explanations of this signal a new test, although it does not yet identify which material or emission process caused the bend.
Fast radio bursts are brief astronomical radio flashes whose fading tails can reveal the ionized gas, or plasma, along their paths. Astronomers need to distinguish delays caused by that gas from the shape of the emitted flash, because either can produce a tail. For the burst named FRB20220718B, the fitted tail duration falls more steeply with increasing radio frequency toward the upper end of 400–800 megahertz (MHz). This smooth bend persists in three models that allow different scattering or emission shapes. In the best-fitting model, adding one parameter for the bend reduces the noise-weighted sum of squared residuals by 90.81 and improves predictions for frequency channels withheld from fitting.
Background
Scattering sends some of a burst’s radiation along longer paths through intervening plasma, spreading its arrival over time. A short emitted pulse can therefore acquire a long fading tail. The characteristic tail duration, τ, commonly decreases with observing frequency, ν. A power law, τ proportional to ν raised to a constant exponent, describes a scale-free frequency dependence: the same frequency ratio produces the same duration ratio everywhere in the band.
The Canadian Hydrogen Intensity Mapping Experiment (CHIME) records fast radio bursts (FRBs). Its second burst catalog, CHIME/FRB Catalog 2, models each pulse profile, the intensity over time, with bell-shaped Gaussian emission components and a scattering response whose duration scales as ν⁻⁴. Its public release includes both observed intensity as a function of time and frequency and the fitted models. These make it possible to test more flexible descriptions of individual bursts (CHIME/FRB Collaboration, 2026). Here, the tail-duration spectrum means how tail duration changes with observing frequency. We allow the power-law exponent to vary freely, then test whether adding curvature improves the fit.
A bend inferred with one pulse model need not be a bend in plasma scattering. Direction-dependent scattering can change the response shape, and multiple emitted components can blend into an apparent tail. Simulations have already shown how scattering geometry and an incorrectly assumed response bias inferred frequency dependence (Geyer & Karastergiou, 2016). The question here is whether those alternatives account for the bend in an observed burst.
Data and selection
The sample comprised all 71 catalog bursts meeting five criteria: a catalog scattering duration above 30 milliseconds (ms), emission spanning more than 250 MHz, one fitted component, detection signal-to-noise ratio at least 25, and no sidelobe flag, which marks detection through a secondary region of the telescope’s directional response. Fitting tails in separate frequency bands revealed conspicuous curvature in three bursts, FRB20220222B, FRB20220718B and FRB20230905D. FRB20220718B has the cleaner profile and a tail better contained within the recorded window; the detailed model comparisons below use this burst.
The public intensity release provides 16,384 frequency channels, narrow intervals of observing frequency, and 326 time samples for this burst. Each time sample spans 0.98304 ms. The window extends from −160.43 to +159.06 ms relative to the catalog arrival, leaving only about three low-frequency tail decay times after the onset. Each decay time is the interval over which an exponential tail falls by a factor of e. We therefore fit the background intensity, or baseline, with both an offset and a slope over time. The principal analysis averages usable channels into sixteen 25-MHz bands, retaining all 326 time samples in each. Released model intensities serve only as a control and as smooth spectral weights for frequency integration; the fitted observations are the measured intensities.
Results
Tail duration across frequency
All three tested pulse families prefer a tail spectrum that steepens toward higher frequency. We describe the response scale by
Here log is the natural logarithm, a sets the duration at 600 MHz, α is the logarithmic slope there, and c measures curvature. The power-law model fixes c to zero and fits α. The curved model adds c as its only extra parameter. Negative c means that the local logarithmic slope, α + 2cx, becomes more negative as frequency increases. The curve describes a smooth bend.
Each pulse family combines a model for emitted intensity with a distribution of propagation delays, called the scattering response. This combination, or convolution, predicts the observed profile. The first family combines one Gaussian emission pulse with an exponential scattering response. The second replaces that response with the delay distribution from an elliptical Gaussian scattering image, an apparent angular distribution of scattered radiation that allows scattering to be stronger in one direction. Its two angular scales have the same frequency dependence. The third returns to an exponential response but allows two Gaussian emission components with different widths. The secondary component has a frequency-independent width and delay, while its share of the fluence, the time-integrated intensity, varies smoothly with frequency. All families allow the primary emission pulse’s width and arrival time to vary independently between bands.
A residual is the difference between observed and fitted intensity. Table 1 reports Q, the sum of squared residuals, each divided by its estimated noise variance. Lower Q indicates a closer fit. Each improvement, ΔQ, compares models within the same pulse family, with all other fitted quantities readjusted.
| Pulse family | Scale-free Q | Curved Q | Improvement | Curvature c |
|---|---|---|---|---|
| Single Gaussian, exponential | 5470.49 | 5344.72 | 125.77 | −8.22 |
| Single Gaussian, elliptical screen | 5369.89 | 5288.85 | 81.04 | −8.45 |
| Two unequal-width Gaussians, exponential | 5280.99 | 5190.18 | 90.81 | −7.26 |
Table 1. Fits to 5,216 band–time samples. The final curved two-component fit has 5,129 nominal residual degrees of freedom, the sample count minus the fitted parameter count.

Figure 1. Best-fitting power-law and curved response scales within each family. These lines summarize joint profile fits, rather than independent duration measurements at each frequency; uncertainty bands are not shown. The elliptical model's scale refers to its major angular axis and has a different normalization from the exponential decay time. Compare the bend within panels rather than the absolute scales between families.
The curved two-component model gives exponential decay times of 42.9, 12.7 and 1.26 ms at 400, 600 and 800 MHz. Its secondary Gaussian has a standard deviation of 13.2 ms, a delay of 12.8 ms and a fluence fraction of 0.34 at 600 MHz.
Allowing the broad secondary component also improves the fit near the pulse onset. For the curved two-component model, the mean square of the residuals normalized by the estimated noise standard deviation is 1.046 during 0–20 ms, compared with 0.995 before the pulse and 0.963 after 40 ms. The curved single-Gaussian model has an early value of 1.34. Thus the curvature preference persists in a family whose early residuals are much closer to the measured noise level.

Figure 2. Observed intensity and fitted profiles in four representative bands (left), and their residuals (right), all divided by the estimated band noise. Time is relative to the catalog arrival. The models use all sixteen bands. A broad secondary component improves the profile description, while adding curvature within that family gives a further improvement.
Tests of alternative pulse shapes
Scale-free directional scattering and secondary emission improve overall fits but generate little curvature when their predicted profiles are fitted with the single-Gaussian exponential model. We tested this by taking each best-fitting scale-free model's noiseless predicted intensities and fitting them with the single-Gaussian exponential family, both with and without curvature. If an alternative pulse shape created the observed bend as a fitting artifact, this procedure should reproduce it.
The scale-free elliptical prediction gives c = −0.97 and a curvature improvement of only 1.47. The scale-free two-component prediction gives c = −1.81 and improvement 5.62. Both are small beside c = −8.22 and improvement 125.77 for the observed intensities. Fitting the scale-free two-component prediction with elliptical responses likewise gives a curvature improvement of only 0.64. These alternatives address other profile features without reproducing most of the measured bend.
We also tested two more restricted models. A centered circular scattering screen, a layer of scattering material with a hard maximum delay, moves its fitted cutoff outside the observed window and gains essentially nothing over a scale-free exponential. This tests that specific finite-screen geometry. A constrained emission model forced the secondary width to be a shared multiple of the primary width; the fit reached the allowed ratio boundary as some primary pulses became unresolved. The two-component model in Table 1 instead gives the secondary its own width.
Predictions for withheld frequency channels
The curved two-component model predicts channels withheld from fitting better than its power-law counterpart. We divided native frequency channels into even and odd sets before averaging. A model fitted to one set predicted the other with pulse and baseline parameters fixed; we then reversed the sets. This retains the pulse onset in both training sets, where arrival time and width are constrained.
Summed across both directions, curvature lowers the withheld Q from 10832.54 to 10730.31 over the full window, from 3241.80 to 3152.57 during −10 to 80 ms, and from 824.63 to 779.19 during 0–20 ms. The corresponding sample counts are 10,432, 2,912 and 640. Each window improves in each direction separately. Training-half curvature estimates are −8.25 and −6.68.
Two checks of data handling retain almost the same improvement. Excluding every channel whose data-quality flag changes during the window gives ΔQ = 87.47 and c = −7.12. Halving the band width to 12.5 MHz and increasing the frequency-integration cells, the intervals used to average the model over each band, from three to five gives ΔQ = 91.37 and c = −7.10. Processing the released scale-free temporal model as a control produces an improvement below 0.0001 in the single-Gaussian family.
Simulations using noise measured outside the pulse also produce much smaller improvements than the observations. Adding resampled noise to the fitted scale-free models and refitting gives maximum ΔQ values of 9.86 in 99 single-Gaussian trials, 8.91 in 19 elliptical trials, and 2.38 in 19 two-component trials. To limit computational cost, the elliptical simulation stopped at 19 of 99 trials, based on inspection of intermediate results.
Interpretation
For FRB20220718B, a single power-law relation between tail duration and frequency misses information about the pulse shape in all three tested families. A broad secondary component provides the closest profile fit, and allowing curvature improves that fit further. Physical explanations of this burst must account for both the profile and its changing frequency dependence.
The bend remains model-dependent. Emission with more general frequency-dependent widths or drifting components could change the inferred scattering law; the fitted components need not represent separate emission episodes. Frequency integration and within-band pulse changes are approximate, while shared instrumental errors, noise from the pulse itself and changing baselines are not fully calibrated. Withheld neighboring channels share such effects, and their fits start from full-data solutions, so prediction is a conditional check rather than blind validation. Selection of this burst, the small noise simulations and the adaptively reduced elliptical trial count prevent interpreting the fit improvements as Gaussian significances, selection-adjusted discovery probabilities or a population frequency; the other two selected bursts provide no independent confirmation. The smooth bend leaves a sharp break, a physical screen size and a unique scattering mechanism undetermined.
Methods
We used the observed total-intensity data, flags, time and frequency coordinates, and noise statistics from the Catalog 2 release dated 2025 December 31. Checksums, digital fingerprints of the files, were used to check input integrity. Channel averaging weights each sample by the inverse of its noise variance, giving less weight to noisier samples, and excludes samples flagged as unreliable. Noise errors in each band are rescaled by the standard deviation of 138 pre-pulse samples earlier than −25 ms; the scaling factors range from 0.920 to 1.118.
Each predicted profile combines the emitted Gaussian with its delay response and integrates the result over the recorded time bins. Dispersion, the frequency-dependent travel time through plasma, spreads arrivals even within a single frequency channel. We represent that spread with a uniform delay distribution, integrated with three-point Gaussian quadrature, a weighted numerical integration rule. We use the file’s dispersion measure, which describes the electron column along the signal’s path, and response constants. Three frequency cells per 25-MHz band approximate the spectral average, weighted by the released smooth spectral envelope and channel inverse variance. This incorporates frequency-dependent scattering and dispersion smearing across each band.
For the elliptical response, τ is the delay scale associated with the major angular axis. We average exponential responses with scales τ(cos²θ + q sin²θ), where θ is uniform in angle and q is the minor-to-major angular variance ratio. Both q and the frequency law are shared across bands. Fits use sixteen angular quadrature nodes and were checked with 64; Q changes by less than 0.001. For two-component emission, the secondary fluence fraction is 1/[1 + exp(−r₀ − r₁x)]. The parameters r₀ and r₁ set the fraction at the reference frequency and its change with log frequency. They, the positive delay and the Gaussian width are shared across bands. Both emission components share the same exponential response.
We fit response and emission parameters by nonlinear least squares, minimizing Q within specified parameter bounds. At every step, we solve for fluence, baseline offset and linear time slope by weighted linear least squares independently in each band. Arrival offsets are bounded within ±25 ms and primary Gaussian standard deviations within 0.05–40 ms; the secondary width spans 0.05–80 ms and its delay 0.2–100 ms. All final fluences are positive. The final primary widths range from 0.071 to 2.798 ms, so the narrowest are not resolved intrinsic-width measurements. Fits from multiple starting parameter values agree for the final comparisons, including secondary-width starts of 3, 10, 30 and 60 ms and curvature starts of 0, −8 and +8. Analytic response limits and recovery of noiseless injected parameters check the implementations.
Noise simulations subtract the mean from the noise-normalized residuals measured outside the pulse in each band. They resample all bands together in blocks of eight time samples, wrapping around the end of the residual series when needed. Adding these blocks to a fitted scale-free prediction preserves short-range temporal and inter-band dependence under stationary off-pulse noise. Each simulated dataset is refitted with both the power-law model and the curved model that contains it as the c = 0 case. All simulation fits report convergence. The measured mean correlation between successive time samples is −0.039, and the mean correlation between bands is −0.0083; these averages alone do not establish independent noise.
References
CHIME/FRB Collaboration (2026). The Second CHIME/FRB Catalog of Fast Radio Bursts. Public data: CHIME/FRB Catalog 2 release.
Geyer, M. & Karastergiou, A. (2016; revised 2021). The frequency dependence of scattering imprints on pulsar observations.