# Review 1

**Outcome: minor-revisions**

## Assessment

This is a useful measurement audit, not merely another iron–stroke MR estimate. The important finding is that a larger outcome release supplies less precision at the exact instruments, while nearby markers retain information and subtype releases omit instruments altogether. The genome-wide extension and the frozen historical SiGN panel take the paper beyond an isolated three-SNP anomaly. An expert should change how they assess an outcome update: check instrument-level information and availability before interpreting attenuation or subtype differences.

The evidence supports that narrow contribution. It does not identify the responsible processing step, establish an iron effect, or show that the earlier causal interpretation was correct. The manuscript generally respects those distinctions, including the overlapping samples, precision-selected tags, and difference between public SiGN and the actual submitted subset.

## What I reran

I ran `analysis/run_paper.sh --cached` in an isolated temporary study copy, leaving the submitted files untouched. I omitted the genome-wide numeric caches so that the three complete original GIGASTROKE subtype files were reparsed. The pipeline completed successfully; 18 key numerical CSV outputs matched the submitted outputs at a tolerance of 1e-12, and the regenerated manuscript tables were unchanged. This was a cached-input replay, not a fresh-download test.

I also independently recomputed the three headline IVW estimates from the extracted exposure and outcome coefficients, without calling the study's fitting function:

| Cardioembolic outcome | OR | Fixed 95% CI | Fixed log-OR SE | Q |
| --- | --- | --- | --- | --- |
| MEGASTROKE, transancestry | 1.157692 | 1.013593–1.322277 | 0.067820 | 2.383499 |
| MEGASTROKE, European | 1.187772 | 1.032623–1.366232 | 0.071417 | 1.514399 |
| GIGASTROKE, European | 0.999008 | 0.835662–1.194283 | 0.091091 | 9.280063 |

The GIGASTROKE random-effects interval also reproduces: 0.680058–1.467547. The raw outcome SE increases at all three instruments are real, not a consequence of exposure scaling or comparing ancestries.

The larger audit also reproduces. Outside chromosomes 6 and 22, 51,449/58,429 low-information variants are absent from small-vessel results, versus 32,257/4,945,909 other common variants. The Kanta tag/sentinel exposure ratios and approximately 2.3-fold outcome-information contrasts reproduce. All three complete original subtype files pass their deposited MD5 checks; the independent raw-row verification also passes.

The full SiGN scans and independent AWK checks recover 84 of 86 requested variants in each outcome, including all six iron sentinels/comparisons. The panel retains 38/40 low-information markers and 40/40 comparators. On the same 38 complete pairs, median information ratios are 1.000000 for SiGN cardioembolism and 0.999796 for SiGN small-artery occlusion, versus 0.416355 for GIGASTROKE cardioembolism. These support the reported historical comparison, not identification of a particular cohort or QC failure.

## The single most important revision: correct the historical subtype baseline

The subsection on subtype comparisons says the later release cannot reconstruct the **“original three-instrument small-vessel analysis.” That analysis did not exist.** Gill et al. explicitly report that rs1800562 was unavailable for small-vessel stroke, with no suitable proxy, and that their small-vessel estimate used **two SNPs**. Their reported serum-iron OR was 0.98 (0.84–1.15). This is stated in the original Results and in the retained `data/PMC6257507.txt`. [Gill et al., 2018](https://pmc.ncbi.nlm.nih.gov/articles/PMC6257507/)

This matters to the argument, not just the wording. Instrument composition already differed across subtypes in the original paper; the later release did not introduce that problem from an originally uniform three-instrument baseline. The finding that GIGASTROKE small-vessel results contain none of the three intended instruments remains correct.

Replace the erroneous reconstruction claim and explicitly distinguish the intended three-SNP panel from the two-SNP small-vessel analysis actually published. A compact historical availability table would make the point clearest: identify the release, ancestry, subtype, and available instruments, keeping public SiGN separate from the exact MEGASTROKE/GIGASTROKE inputs. Do not assume that the original transancestry small-vessel availability establishes the European MEGASTROKE baseline without checking it. The discussion should then acknowledge that the original subtype comparison also changed its genetic experiment; this observation alone does not demonstrate that its subtype interpretation was wrong.

## Scope of the remaining uncertainty

The exact submitted inputs and pre-/post-QC participation records would be the most valuable next scientific evidence. I would not make resolving that unavailable provenance a condition of accepting this explicitly limited audit. The authors have pursued the interesting question beyond the initial attenuation result with genuinely discriminating comparisons, and have not claimed to explain what remains unknown. Preserve that restraint: low information is not proof of erroneous QC, and wider intervals do not rehabilitate the original causal claim. With the historical subtype correction, the main paper is supported.
