# The larger GIGASTROKE release gives less precise stroke estimates at all three iron instruments

The larger GIGASTROKE genetic study gives less precise stroke associations at all three variants used by Gill et al. to test whether higher iron levels increase stroke risk. Its small-vessel stroke results omit all three. We reproduce the original association with cardioembolic stroke, caused by clots originating in the heart, but the later estimate near zero has a wider confidence interval. A genome-wide audit and an earlier stroke dataset show that this loss of precision and variant coverage extends beyond the iron markers. Study size alone therefore gives a misleading guide to the strength of this updated test.

## Background

Gill et al. reported in 2018 that genetically predicted higher iron status increased stroke risk, with the strongest evidence for cardioembolic stroke. Their headline outcome was any stroke; ischemic stroke, caused by blocked blood flow, and its subtypes were separate analyses. The study offered evidence about causation that ordinary comparisons of people with different iron levels could not readily provide. Later analyses using larger iron studies also supported the cardioembolic association, making it important to understand what a newer stroke dataset adds. [Gill et al., 2018](https://doi.org/10.1161/STROKEAHA.118.022701); [Barad et al., 2024](https://doi.org/10.1161/JAHA.124.034991)

The method, Mendelian randomization (MR), uses genetic variants associated with an exposure as natural experiments. A variant's association with stroke is divided by its association with iron to estimate the effect of higher iron levels. This interpretation assumes that the variant affects stroke through iron rather than through another pathway. Gill and colleagues chose three variants whose effects agreed across four iron biomarkers: serum iron, ferritin (a marker of iron stores), transferrin (the iron transport protein) and transferrin saturation (the fraction of that protein carrying iron). Two variants, C282Y (rs1800562) and H63D (rs1799945), lie in the HFE gene; the third, rs855791, lies in TMPRSS6. These three variants are the study's genetic instruments.

We first reconstructed the cardioembolic estimate using Gill and colleagues' original transancestry MEGASTROKE outcome data. We then compared European MEGASTROKE and GIGASTROKE results while holding the iron coefficients and instruments fixed. This separates a change in the outcome data from a change in the genetic experiment. The newer result prompted us to examine how precisely each variant was measured, whether nearby variants carried the same iron signal, and whether the pattern occurred elsewhere in the genome.

Our recheck gives no basis for calling Gill and colleagues' original cardioembolic result wrong. Its serum-iron estimate reproduces to the published precision. The unresolved causal conclusion comes from the limits of the update: the newer data provide a less precise test at these instruments, share cohorts with the original data, and leave the instruments' causal assumptions unsettled. Our reconstruction concerns the cardioembolic result rather than every analysis in the original paper.

## Results

### Reconstruction and updated estimate

The original cardioembolic estimate reproduces, while the newer European estimate is less precise at every original instrument. Using the published, rounded iron coefficients and the original three variants, we obtain an odds ratio (OR) of 1.158 per standard-deviation increase in serum iron for transancestry MEGASTROKE cardioembolic stroke. Its 95% confidence interval (CI) is 1.014–1.322, closely matching the published 1.16 (1.01–1.32). The European reconstruction is also positive. European GIGASTROKE gives an estimate near zero on the log-odds scale, with wider intervals (Table 1).

Table 1. Serum-iron estimates using the same exposure coefficients and exact instruments. “Random” denotes multiplicative random-effects intervals, which allow for disagreement among variant estimates. Q measures this disagreement and has two degrees of freedom. SE is standard error.

<!-- table:mr:start -->
| Cardioembolic outcome | OR | Fixed 95% CI | Random 95% CI | Fixed log-OR SE | Q (2 df) |
| --- | --- | --- | --- | --- | --- |
| MEGASTROKE, transancestry | 1.158 | 1.014–1.322 | 1.001–1.338 | 0.0678 | 2.38 |
| MEGASTROKE, European | 1.188 | 1.033–1.366 | 1.033–1.366 | 0.0714 | 1.51 |
| GIGASTROKE, European | 0.999 | 0.836–1.194 | 0.680–1.468 | 0.0911 | 9.28 |
<!-- table:mr:end -->

The loss of precision is visible in the stroke associations before scaling them by iron effects. Outcome standard errors at C282Y, H63D and TMPRSS6 rise from 0.0416, 0.0277 and 0.0194 in European MEGASTROKE to 0.0507, 0.0334 and 0.0266 in European GIGASTROKE. The MR log-OR standard error rises from 0.0714 to 0.0911. The comparison within European results rules out the change from transancestry to European data as the explanation.

GIGASTROKE's European cardioembolic sample has 10,804 cases. Its source table assigns 6,189 to unchanged MEGASTROKE cohorts, 718 to updated cohorts and 3,897 to new cohorts. These labels describe cohorts rather than individual overlap. We therefore compare the releases without pooling them or testing their difference as independent estimates. [Mishra et al., 2022](https://doi.org/10.1038/s41586-022-05165-3)

### Nearby HFE variants

Nearby HFE variants carry almost identical measured iron associations but have more than twice the stroke information. This checks whether markers tracking the same iron signal share the loss of precision. The markers rs79220007 and rs198851 track C282Y and H63D, respectively, with observed dosage correlation r²=1 in 503 European 1000 Genomes participants. We checked which alleles at each pair are inherited together. In GIGASTROKE cardioembolic results, these linked markers, or tags, have 2.318 and 2.284 times the inverse-variance information of the original variants.

The tags also have nearly identical measured iron effects. In FinnGen's Kanta laboratory study, the phase-aligned tag/original coefficient ratios are 0.998866 and 0.996455. Thus stronger iron associations at the tags do not explain their better stroke precision. Kanta measures inverse-normalized, within-person median clinical laboratory iron in 56,958 participants, a different scale from the original population iron assays. [Kanta documentation](https://storage.googleapis.com/finngen-public-data-r12/lab_values/analysis_documentation/FinnGen_kanta_lab_documentation_v2.pdf)

With Kanta coefficients throughout, the exact-three cardioembolic OR is 1.013 (fixed 95% CI 0.773–1.328). Replacing only the two HFE variants gives 1.209 (0.993–1.472). Random-effects intervals are wide at 0.565–1.814 and 0.751–1.946. These fits show how marker choice affects the estimate; the tags were selected after inspecting precision. The TMPRSS6 comparison marker rs4820268 has r²≈0.76 with rs855791 and is too weakly correlated to serve as an interchangeable proxy.

### Availability across stroke subtypes

The original iron instruments have low information across several stroke outcomes and disappear from the small-vessel results. To compare precision across variants with different allele frequencies, we calculate an information diagnostic, \(I=1/[2f(1-f)SE^2]\), where \(f\) is allele frequency and SE is the stroke log-OR standard error. We divide it by the median among common variants in the same 500 kb region. Higher values mean greater frequency-adjusted precision; the diagnostic is not a measured sample size.

The original instruments have about 60–66% of local median information for any stroke, 57–63% for ischemic stroke and 38–43% for cardioembolic stroke. The nearby comparison markers remain close to their local medians (Figure 1).

![Information and availability at the same six variants across stroke outcomes](results/stroke_information.svg)

Figure 1. Relative information and availability in European GIGASTROKE. Cells show information divided by the common-variant median in the same 500 kb region. Dashed cells indicate absence. The outcomes overlap, and the TMPRSS6 comparison is only partially correlated with its original variant.

Large-artery stroke retains only H63D from the original panel; small-vessel stroke retains none. Full scans of 5,784,788 original large-artery and 5,974,028 original small-vessel rows confirm these five absences before GWAS Catalog harmonization. Gill and colleagues already used only two instruments for small-vessel stroke because C282Y and a suitable proxy were unavailable in MEGASTROKE. GIGASTROKE therefore extends an existing coverage problem: none of the original three is available for this subtype. Using whichever instruments remain would compare different genetic experiments across subtypes. [Gill et al., 2018](https://doi.org/10.1161/STROKEAHA.118.022701)

### Genome-wide precision and availability

Low cardioembolic information accompanies extensive absence from small-vessel results across the genome. We extended the audit to common variants present in the original European cardioembolic file, defining common as minor-allele frequency (MAF) ≥0.05. Here we normalized information by chromosome medians. Excluding chromosomes 6 and 22, which contain the iron instruments, leaves 5,004,338 variants. Of these, 58,429 have information below half their chromosome median. Small-vessel results lack 88.05% of this low-information group, compared with 0.65% of other common variants (Table 2).

Table 2. Subtype availability outside chromosomes 6 and 22, grouped by cardioembolic information. Variants are correlated and outcomes overlap, so the counts are descriptive rather than independent observations for significance testing.

<!-- table:dropout:start -->
| Cardioembolic information | Variants | Absent: large artery | Absent: small vessel |
| --- | --- | --- | --- |
| Below half chromosome median | 58,429 | 28,146 (48.17%) | 51,449 (88.05%) |
| Other common variants | 4,945,909 | 49,491 (1.00%) | 32,257 (0.65%) |
<!-- table:dropout:end -->

The pattern persists at high allele frequency. Among variants with MAF 0.30–0.50, small-vessel results lack 14,983/17,032 (88.0%) low-information variants and 191/1,647,717 (0.0116%) other variants. Across four frequency strata, the low-information group has median normalized cardioembolic information near 0.42.

Genotyping-array content and manufacturer names do not explain the general deficit. The original iron variants appear on a HumanExome array manifest, a list of markers targeted by that array. Outside chromosomes 6 and 22, low information is more common among manifest markers than other variants (7.55% versus 1.14%), but most affected variants fall outside the manifest. Among markers with numeric manufacturer identifiers beginning with “exm”, having multiple names also fails to identify the low-information group: its frequency is 8.78% for markers with multiple names and 11.69% for those with one name (Figure 2).

![Genome-wide subtype dropout by allele frequency and the manufacturer-name comparison](results/array_audit.svg)

Figure 2. Variant absence and manufacturer names. Both panels exclude chromosomes 6 and 22. Left: small-vessel absence by cardioembolic information group and MAF. Right: low-information fractions among numeric-`exm` markers grouped by number of manufacturer names.

### Earlier SiGN results

Most selected low-information variants had normal relative precision in the earlier Stroke Genetics Network (SiGN) results. This historical comparison tests whether the later deficit was already present in an earlier stroke dataset. Before extracting their results from public European SiGN files, we fixed 40 low/normal-information pairs matched on chromosome, HumanExome membership, allele frequency and position. All have later cardioembolic MAF ≥0.30. [SiGN dataset](https://kp4cd.org/node/1173)

Both earlier outcomes contain 38/40 low-information markers and all 40 normal comparators. Of the low markers, 36 participate in every reported analysis stratum; all 40 comparators do. On the same 38 complete pairs, median low/normal information is 1.000 in each earlier outcome and 0.416 in later cardioembolic results (Table 3). Later small-vessel results omit 39/40 low markers and retain all 40 comparators.

Table 3. Historical coverage and information in the fixed panel. Groups are defined from GIGASTROKE cardioembolic information. Presence and participation use all 40 pairs; both information medians use the identical 38 complete pairs. CES denotes cardioembolic stroke. Ratios compare information within pairs.

<!-- table:source:start -->
| Earlier outcome | Low present | Normal present | All strata: low; normal | SiGN median ratio (38 pairs) | GIGASTROKE CES ratio (same 38) |
| --- | --- | --- | --- | --- | --- |
| SiGN cardioembolic | 38/40 | 40/40 | 36/40; 40/40 | 1.000 | 0.416 |
| SiGN small artery | 38/40 | 40/40 | 36/40; 40/40 | 1.000 | 0.416 |
<!-- table:source:end -->

All six iron variants are present in SiGN and contribute across all 10 reported cardioembolic and 9 small-artery strata. HFE tag/original inverse-variance ratios are 0.997 and 1.000 for cardioembolism and 1.000 for both small-artery pairs. The later precision disparity and variant loss therefore vary by dataset.

![Information in the fixed matched panel across later and earlier stroke releases](results/source_panel.svg)

Figure 3. Information ratios in earlier SiGN and later GIGASTROKE. Each point is a matched pair. Selection imposed the x-axis contrast; the y-axis was unused in selection. Dashed horizontal lines indicate equal information within a pair; dotted diagonals indicate equal ratios across releases. Each panel shows 38 complete pairs. Two low markers are absent and two others have incomplete stratum participation. All remain in the coverage denominators.

## Interpretation and limits

At these iron instruments, the larger stroke release supplies a less precise test and incomplete subtype coverage. The earlier public SiGN results show that most selected low-information variants once had precision comparable to matched markers. Exact variant availability and outcome standard errors should therefore accompany MR updates and subtype comparisons. Nearby tags can help diagnose a precision problem when their exposure effects are measured and their selection rule is explicit.

The cause of the deficit remains unresolved. Public SiGN differs from the non-overlapping subset submitted to GIGASTROKE, and the public meta-analysis files lack per-variant participation and exclusion reasons. The selected high-frequency panel cannot estimate genome-wide historical prevalence, and our genome-wide audit covers only variants present in cardioembolic results. Manufacturer annotations do not establish actual cohort genotyping or submitted names. Participation, imputation, estimation and quality-control filtering remain possible explanations. The causal iron effect also remains uncertain: the releases share cohorts, the tags were precision-selected, reference correlations may vary across cohorts, and iron-regulatory variants may affect stroke through other pathways. These estimates do not establish the effect of an iron intervention.

The next useful evidence is the exact submitted cohort inputs and pre- and post-quality-control participation records for the fixed panel. Those records could locate where precision and availability changed.

## Methods

### Analysis sequence and MR estimation

This was a sequential exploratory investigation. Reconstruction preceded regional precision checks, linked-marker selection, measured-exposure calibration, subtype availability, genome-wide annotations and the historical panel. The array-content test was recorded before genome-wide matching; marker-name multiplicity was a subsequent hypothesis. The historical panel was fixed before its SiGN rows were extracted.

We extract Genetics of Iron Status (GIS) exposure coefficients from Gill's supplement, preserve allele frequencies and align outcome alleles explicitly. H63D's palindromic C/G alleles are resolved by frequency. The primary reconstruction uses the three exact variants. For iron coefficients \(b_X\), stroke log-ORs \(b_Y\) and their standard errors \(SE_Y\), the inverse-variance-weighted estimate is

\[
\hat\theta=\frac{\sum b_Xb_Y/SE_Y^2}{\sum b_X^2/SE_Y^2},\qquad
SE(\hat\theta)=\left(\sum b_X^2/SE_Y^2\right)^{-1/2}.
\]

Random-effects standard errors multiply this by \(\sqrt{\max(1,Q/(k-1))}\), where \(k\) is the number of variants and Q measures heterogeneity. Intervals use ±1.96 SE on the log scale. Delta-weighted sensitivity includes exposure uncertainty in ratio variances. The published exposure coefficients are rounded. The two HFE variants have reference correlation r=0.074; the primary diagonal-weight fit follows the original reconstruction. The three variants represent two genetic regions, and the correlated iron biomarkers supply related estimates.

### Data and information measures

MEGASTROKE cardioembolic accessions are GCST005842 (transancestry) and GCST006910 (European). European GIGASTROKE accessions GCST90104539–GCST90104543 cover any, ischemic, cardioembolic, large-artery and small-vessel stroke. We use univariate releases. Regional queries use harmonized GRCh38 coordinates and verified alleles; original-file availability and genome-wide matching use GRCh37 coordinates plus allele sets. GIGASTROKE used ancestry-specific fixed-effect meta-analysis with cohort- and meta-analysis-level quality control, including participation and heterogeneity filters. [GIGASTROKE methods](https://pmc.ncbi.nlm.nih.gov/articles/PMC9524349/)

Information medians use common variants in two fixed 500 kb windows for regional comparisons and on the same chromosome for genome-wide comparisons. The genome-wide universe contains 5,422,856 cardioembolic variants before excluding chromosomes 6 and 22. HumanExome v1.2 content is matched by GRCh37 coordinate and forward-strand allele set, collapsing duplicate probes. Omni5Exome v1.0 auxiliary assignments supply marker-name multiplicity. [HumanExome manifest](https://www.ncbi.nlm.nih.gov/geo/query/acc.cgi?acc=GPL20019); [manufacturer files](https://emea.support.illumina.com/array/array_kits/infinium_humanomni5exome_beadchip_kit/downloads.html)

The historical panel has one pair on each of the 20 non-iron autosomes within each HumanExome-membership category. Both markers have MAF ≥0.30, differ by ≤0.02 in MAF and lie ≤1 Mb apart. Low information is <0.5 chromosome median; normal is 0.9–1.1. Hash ordering selects eligible low markers and distance selects comparators, without using SiGN results. We extract European cardioembolism and small-artery occlusion results classified by the Trial of Org 10172 in Acute Stroke Treatment (TOAST) system. Stratum participation comes from direction strings, checked against heterogeneity degrees of freedom plus one. SiGN’s reported effective sample size is retained separately from our information diagnostic. [SiGN publication and supplement](https://handls.nih.gov/pubs/2016-SIGN-LancetNeurol-15-174.pdf)

All three complete original subtype files pass deposited MD5 checks. Independent weighted regression checks MR arithmetic, independent raw-row parsing checks information calculations, and independent full-file scans verify all 86 requested SiGN positions per outcome, including absences.

## References and acknowledgments

1. Gill D et al. Iron Status and Risk of Stroke. *Stroke* (2018). [doi:10.1161/STROKEAHA.118.022701](https://doi.org/10.1161/STROKEAHA.118.022701).
2. Benyamin B et al. Novel loci affecting iron homeostasis and their effects in individuals at risk for hemochromatosis. *Nature Communications* (2014). [doi:10.1038/ncomms5926](https://doi.org/10.1038/ncomms5926).
3. Malik R et al. Multiancestry genome-wide association study of 520,000 subjects identifies 32 loci associated with stroke and stroke subtypes. *Nature Genetics* (2018). [doi:10.1038/s41588-018-0058-3](https://doi.org/10.1038/s41588-018-0058-3).
4. Mishra A et al. Stroke genetics informs drug discovery and risk prediction across ancestries. *Nature* (2022). [doi:10.1038/s41586-022-05165-3](https://doi.org/10.1038/s41586-022-05165-3).
5. Barad A et al. Associations Between Genetically Predicted Iron Status and Cardiovascular Disease Risk: A Mendelian Randomization Study. *Journal of the American Heart Association* (2024). [doi:10.1161/JAHA.124.034991](https://doi.org/10.1161/JAHA.124.034991).
6. Allara E et al. Novel loci and biomedical consequences of iron homoeostasis variation. *Communications Biology* (2024). [doi:10.1038/s42003-024-07115-3](https://doi.org/10.1038/s42003-024-07115-3).
7. NINDS Stroke Genetics Network and International Stroke Genetics Consortium. Loci associated with ischaemic stroke and its subtypes (SiGN): a genome-wide association study. *Lancet Neurology* (2016). [doi:10.1016/S1474-4422(15)00338-5](https://doi.org/10.1016/S1474-4422(15)00338-5).

We thank the participants and investigators of the source studies. The MEGASTROKE project received funding from sources specified at [its acknowledgments page](https://www.megastroke.org/acknowledgements.html); its requested [consortium author-list supplement](MEGASTROKE_AUTHORS.md) preserves source names and affiliations. These are source-study contributors, not authors of this reanalysis. We acknowledge GIGASTROKE, FinnGen and its public laboratory-GWAS resource, and SiGN/ISGC through the Cerebrovascular Disease Knowledge Portal.
