# Review 2

Outcome: minor-revisions

## Assessment

The main finding is supported and useful: a larger stroke release provides less precise cardioembolic associations at all three original iron instruments, while subtype availability also deteriorates. An expert should check exact-instrument precision and availability before treating a newer outcome dataset as a stronger causal test. The manuscript states this clearly and keeps the uncertain iron effect separate from the observed measurement problem.

The work has pursued the interesting question beyond a changed MR estimate. The linked HFE markers, measured exposure calibration, genome-wide dropout pattern and historical SiGN panel establish that this is more than an isolated three-variant anomaly. The historical comparison could have shown that the selected variants were consistently poorly measured; instead, their earlier precision generally matches their comparators. It does not locate the responsible processing step, and the paper correctly distinguishes public SiGN from the subset submitted to later meta-analyses. Obtaining the actual submitted inputs would be valuable, but is not a prerequisite for this bounded claim.

## Reproduction and numerical checks

I ran `analysis/run_paper.sh --cached` successfully in a temporary study copy. Large existing inputs and numeric caches were linked for reading; generated outputs stayed in the temporary copy. This was a cached-input replay, not a fresh-download test or a complete rebuild of the genome-wide numeric caches. Fifteen key numerical CSV outputs agreed with the submitted results at tolerance 1e-12, and regenerating the manuscript left its tables unchanged.

I independently recomputed the headline serum-iron IVW estimates from the aligned coefficients, without using the study's fitting function:

| Cardioembolic outcome | OR | Fixed 95% CI | Log-OR SE | Q |
| --- | --- | --- | --- | --- |
| MEGASTROKE, transancestry | 1.157692 | 1.013593–1.322277 | 0.067820 | 2.383499 |
| MEGASTROKE, European | 1.187772 | 1.032623–1.366232 | 0.071417 | 1.514399 |
| GIGASTROKE, European | 0.999008 | 0.835662–1.194283 | 0.091091 | 9.280063 |

The raw outcome SEs increase at all three variants within the European comparison. The approximately 2.3-fold HFE tag information advantage and nearly identical measured iron coefficients reproduce. Outside chromosomes 6 and 22, the small-vessel absence counts reproduce as 51,449/58,429 low-information variants versus 32,257/4,945,909 others.

The replay's source checks passed: deposited MD5s for all three original subtype files, independent arithmetic on 237 raw cardioembolic rows, and full-file SiGN AWK scans recovering 84 of 86 requested variants in each outcome. The identical 38-pair comparisons reproduce median information ratios of 1.000000 and 0.999796 in earlier SiGN outcomes, versus 0.416355 in later cardioembolic results. These checks support extraction and arithmetic, not a causal explanation for the deficit.

## Single most important revision

Finish the historical subtype clarification requested in review 1. The incorrect reference to an original three-instrument small-vessel analysis is gone, but the current availability subsection still omits the actual baseline: Gill et al. lacked rs1800562 and a suitable proxy for small-vessel stroke, so their published analysis used two instruments. This is explicit in the original Results, also retained in `data/PMC6257507.txt`. [Gill et al., 2018](https://pmc.ncbi.nlm.nih.gov/articles/PMC6257507/)

Add a sentence stating that fact beside the later zero-of-three availability result. Explain that instrument composition already varied across subtypes in the original analysis; the GIGASTROKE finding documents further loss rather than the introduction of this problem. Do not infer European MEGASTROKE availability from the original transancestry analysis or from public SiGN. No new historical table or analysis is needed to make this limited correction.

With that clarification, I would accept the paper. Further causal estimators or generic sensitivity analyses would not improve its central contribution.
