# Review 3

Outcome: accept

## Assessment

The paper supports a useful, bounded conclusion: a larger stroke GWAS release need not give a stronger test at the genetic instruments actually used. At all three original iron instruments, the newer European cardioembolic associations are less precise; subtype coverage also deteriorates. The linked-marker comparisons, genome-wide audit and historical SiGN panel turn an otherwise routine MR update into evidence that should change how experts assess outcome releases.

The investigation follows the interesting question raised by the initial near-null estimate. In particular, earlier SiGN precision could have shown that the selected markers were consistently poorly measured. Instead, their earlier information generally matches that of the comparison markers. This supports a release-dependent measurement problem, without identifying its cause. The manuscript appropriately avoids equating its information diagnostic with actual sample size or attributing the deficit to a particular cohort, array or QC error.

## Reproduction checks

I ran `analysis/run_paper.sh --cached` successfully in a separate temporary copy of the study. This used existing inputs and genome-wide numeric caches, rather than fresh downloads or a complete numeric-cache rebuild. Twelve key numerical CSV outputs matched the submitted versions at tolerance 1e-12, and the regenerated manuscript was byte-identical.

I also independently recomputed the headline IVW estimates from the aligned exposure and outcome coefficients without calling the study's fitting function:

| Cardioembolic outcome | OR | Fixed 95% CI | Log-OR SE | Q |
| --- | --- | --- | --- | --- |
| MEGASTROKE, transancestry | 1.157692 | 1.013593–1.322277 | 0.067820 | 2.383499 |
| MEGASTROKE, European | 1.187772 | 1.032623–1.366232 | 0.071417 | 1.514399 |
| GIGASTROKE, European | 0.999008 | 0.835662–1.194283 | 0.091091 | 9.280063 |

The raw outcome SE increases reproduce at every instrument: 0.0416 to 0.0507, 0.0277 to 0.0334, and 0.0194 to 0.0266 within the European comparison. The approximately 2.3-fold HFE tag information advantages and near-identical measured iron coefficients also reproduce.

The replay recovers the genome-wide small-vessel absence counts outside chromosomes 6 and 22: 51,449/58,429 low-information variants versus 32,257/4,945,909 others. Its independent verification checks pass all three original-file MD5s and information arithmetic on 237 raw cardioembolic rows. Full original large-artery and small-vessel scans confirm the claimed instrument absences.

Both full-file SiGN verification scans recover 84 of 86 requested variants. The historical panel retains 38/40 low-information markers and all 40 comparators. On the same 38 complete pairs, the earlier information-ratio medians are 1.000000 and 0.999796, compared with 0.416355 in later cardioembolic results. These checks establish extraction and arithmetic, not why information changed.

## Interpretation, writing and record

The historical subtype clarification requested in the earlier reviews is now present. The manuscript correctly says that Gill et al. already used only two small-vessel instruments because C282Y and a suitable proxy were unavailable. This agrees with the original Results retained in the study's source text. The later zero-of-three coverage therefore extends an existing problem rather than introducing it. [Gill et al., 2018](https://pmc.ncbi.nlm.nih.gov/articles/PMC6257507/)

The paper is clear that the original cardioembolic estimate reproduces and that no original numerical error has been identified. It neither treats attenuation as a refutation nor uses wider intervals to vindicate the causal claim. Background definitions make the central argument accessible outside MR; the technical array and historical comparisons remain connected to that argument.

The record is fair. `type: reproduction`, `numbers: yes` and `conclusion: unclear` match the explicitly limited reconstruction and unresolved causal inference. The note scopes numerical agreement to the serum-iron cardioembolic estimate. The plain-language summary distinguishes the genetic association from the effects of taking supplements and does not imply that the original study was shown wrong.

## Most valuable next improvement

Obtain exact submitted cohort inputs and pre-/post-QC variant participation records for the fixed panel. That would turn the demonstrated release-dependent deficit into an explanation and potentially a remedy. The paper already identifies this evidence gap and has pursued it far enough to support its present claim. I would not make unavailable provenance records, or further generic MR sensitivity analyses, a condition of publication. No substantive revision is required.
