FindingAstronomy

As a wave in the binary star system KIC 8719324 faded, its brightness peak shifted by hours

Version 1 Published 2026-11-21 DOI 10.5281/zenodo.24431017

Importance (self-rated) Notable

The phase change constrains the interpretation of a prominent example of a tidally excited wave: its fade is not just an amplitude change at fixed orbital phase.

Why it matters

As these two stars orbit each other, their light rises and falls about once every nine and a half hours. After the flicker faded, its peaks came two to three hours later in the cycle, timed against the stars’ eclipse. Two steady waves slipping out of step could explain both changes, so the dimmer flicker alone is a poor guide to whether the stars’ tides have weakened.

When two stars pass close together, their tidal pull can set a star oscillating. Astronomers would like to know whether a fading variation in starlight means that the star's response to the tide has weakened. Brightness alone cannot settle the question. Two steady waves with slightly different frequencies can cancel as they slip out of step. As their combined wave fades, its peak can also move in time.

In the binary star system KIC 8719324, a grazing eclipse provides a clock for timing the peak. Between 2019 and 2024, the peak of a fading 9.45-hour wave shifted by 2.8 hours relative to the eclipse. Three other ways of measuring brightness from the same images gave shifts of 2.1–2.3 hours. Simply weakening a wave that keeps time with the orbit would leave its peak in place. Two steady waves can reproduce the shift, though how well they predict the wave's height depends on which pixels are used to measure the starlight.

The orbital clock

KIC 8719324 is a “heartbeat” binary. Its light shows a brief pulse around the stars' closest approach in each 10.23-day orbit. As Thompson et al. (2012) described, one star also grazes the other in eclipse. The resulting narrow dip in brightness can be timed separately from the pulse. Even away from closest approach, the light oscillates 26 times per orbit, a frequency called the 26th orbital harmonic. Fuller (2017) used this system to illustrate how tides excite stellar oscillations. Guo et al. (2020) used the Kepler space telescope to measure the wave's mean phase, the position of its peak within a cycle. This timing helps identify how a star oscillates if the peak tracks a single wave.

Across 19 stars observed by both Kepler and the Transiting Exoplanet Survey Satellite (TESS), we compared 92 harmonic measurements. We fitted nearby harmonics alongside published oscillations to separate their contributions. At low harmonics, excluding the heartbeat pulse sometimes made neighboring waves hard to distinguish; we set those apparent changes aside. For KIC 8459354, the shorter TESS observations blended frequencies that Kepler could distinguish. In KIC 8719324, the 26th harmonic grew during four years of Kepler observations and faded during TESS observations. Each trend occurred within one telescope's record, so a difference in the telescopes' wavelength ranges cannot explain either trend. In four Kepler image sequences, the center of the fast oscillation lay within 0.05 pixel of the center of the orbital variation. This argues against a resolved neighboring star as the source of the oscillation in those years.

Brightness and timing through the fade

To compare the wave across years, we measured the eclipse time in each observing period and aligned the eclipses to the same point in the orbit. Figure 1 shows the brightness measurements from 2019 and 2024 lined up by their position in the fast wave's cycle. In 2019 the light was rising to its peak in the first half of the cycle; in 2024 it peaked in the second half.

Folded 2019 and 2024 light curves showing the shift in maximum brightness

Figure 1. Each point estimates the brightness in one twelfth of the 9.45-hour cycle without assuming a wave shape. The lines are separate sinusoidal fits to the same raw brightness measurements from the TESS Quick-Look Pipeline (QLP), which extracts starlight from the images. Both fits exclude closest approach and eclipse. Hour zero is the common time reference for the fast wave; the eclipse sets that reference without defining hour zero as the instant of eclipse.

Different choices of aperture (the pixels used to collect the starlight) can change the measured brightness variation. We therefore scaled the fast wave in each aperture by the height of the broad orbital pulse in the raw brightness record, using the Kepler pulse as the reference. We report the fast wave's semi-amplitude, half its peak-to-trough variation, in parts per million (ppm) on that scale. This measures the wave relative to the pulse.

We fitted a cosine and a sine at 26 cycles per orbit. Their coefficients locate the wave on a plot with cosine on one axis and sine on the other. The distance from the origin gives the amplitude and the angle gives the phase of peak brightness. Averaging the two coordinates preserves timing information even when the wave is weak. The amplitude rose from 550 ppm in Kepler observing quarters 1–4 to 672 ppm in quarters 13–17. In TESS it fell from 347 ppm in 2019 to 182 ppm in 2021 and 108 ppm in 2022. By 2024 it measured 182 ppm.

The wave was easier to time at the two ends of the TESS sequence than at the minimum. The mean (cosine, sine) coordinates were (−275, +213) ppm in 2019 and (−64, −171) ppm in 2024. The shorter angle between them was 1.87 radians. Its 95% noise interval of 1.27–2.34 radians accounts for errors shared by the fitted coordinates and for the common eclipse time within each observing period. The interval excludes both an unchanged peak and a half-cycle reversal (π radians). The angle measures the shift within a cycle; whole cycles of drift during gaps in the observations would go uncounted.

The shift persisted when we left the eclipse times uncorrected (1.78 radians) and when we used only the measurements before closest approach (1.98 radians) or after it (1.82 radians). We also summed the same TESS exposures in circular apertures instead of using the QLP brightness measurements. Radii of 1, 1.5 and 2 pixels gave shifts of 1.46, 1.37 and 1.50 radians, respectively. The spread measures sensitivity to the choice of pixels, a source of uncertainty distinct from measurement noise.

Testing two steady waves

A steady wave that keeps time with the orbit stays at one point on the cosine–sine plot. Adding a steady wave of slightly different frequency makes the combined wave trace a circle around that point. When the waves most nearly cancel, the circle passes closest to the origin. The amplitude then reaches its minimum, and the angle can change rapidly. The time to complete the circle is the beat period. In fitting the two waves, we allowed each its own time-independent change in amplitude between the wavelength ranges of Kepler and TESS, with no change in phase.

A fit using observations through 2022 came close to the 2024 QLP measurement in both amplitude and phase (Figure 2). The orbit-locked and the second wave had Kepler amplitudes of 472 and 214 ppm, respectively; their TESS amplitudes were 0.73 and 1.19 times those values. With a beat period of 18.5 years, the fitted waves nearly cancel around January 2023, giving a minimum of 87 ppm. For the four TESS observing intervals (sectors) in 2024, the fit predicts 165 ppm at a phase of −1.91 radians. QLP gives 182 ppm at −1.93 radians.

Two-wave fits and measured wave coefficients in the pipeline and circular apertures

Figure 2. Each point shows the mean cosine and sine coefficients for one TESS observing period. The solid curve starts in 2019. Fitted only to Kepler and TESS data through 2022, it predicts the wave for the two pairs of sectors in 2024 (squares, sectors 74–75 and 81–82). The dashed curve includes 2024 in the fit. Bars show estimated measurement errors of one standard deviation per coordinate, excluding forecast uncertainty.

With a circular aperture of radius 1.5 pixels, repeating both the fit and the measurement put the predicted 2024 wave in the correct quadrant but at more than twice its measured amplitude (Table 1). Requiring both waves to change amplitude by the same factor between Kepler and TESS improved the prediction for this aperture and worsened it for QLP.

Table 1. Amplitude and phase of the mean 2024 wave. Each prediction uses Kepler and the indicated TESS aperture through 2022. Separate responses allow each wave its own amplitude factor between telescopes; a common response uses one factor for both. Phases are in radians (rad) relative to the eclipse-based reference in Figure 1.

TESS aperture Measured Predicted, separate responses Predicted, common response
QLP 182 ppm, −1.93 rad 165 ppm, −1.91 rad 110 ppm, −2.70 rad
1.5-pixel radius 149 ppm, −2.23 rad 329 ppm, −1.75 rad 158 ppm, −2.45 rad

The largest miss was in the sine coefficient for the 1.5-pixel aperture. The fit with separate responses predicted −324 ppm, compared with −118 ppm measured. Under that fit and its noise assumptions, only 3.5% of simulated training and test sets gave a larger discrepancy across the two coordinates together. Even for QLP, where separate responses came closest, the predicted sine coefficient of −156 ppm had a central 95% simulation range from −325 to +12 ppm. The forecast thus allowed even a small positive coefficient.

Including 2024 gives beat periods of 18.4 years for QLP and 18.9 years for the 1.5-pixel aperture. For QLP, periods from 17.5 to 19.2 years fit within the error criterion described in Methods; Kepler alone allows about 11–34 years by the same criterion. The implied second wave runs faster than the orbital harmonic by about 0.00015 cycles per day. That difference is too small to resolve as two frequency peaks in the four-year Kepler record. The period estimate comes from the path of the combined wave.

Interpretation

The eclipse shows that the phase measured during Kepler no longer describes the peak through the fade. Interference offers a plausible explanation. Its longer-term prediction is a sustained recovery after cancellation: for July 2028, the full-data fits in Figure 2 predict 488 ppm at −2.18 radians for QLP and 469 ppm at −2.15 radians for the 1.5-pixel aperture, using the same eclipse reference. These are point predictions. Comparing a new measurement with them before refitting would test that recovery.

The 2024 prediction was retrospective: the four sectors were omitted from the fit, but their summary amplitudes were known when the target was chosen. A simpler forecast also captures the 2024 direction: extending each TESS coordinate along a straight line from 2019–2022 comes within one forecast standard deviation of each measured QLP coordinate. A single wave whose amplitude and phase both vary therefore remains possible. The images cannot assign two putative waves to individual stars or exclude light from an unresolved neighbor. The brightness measurements give neither the strength of the tide nor the energy lost by a stellar oscillation.

Methods

Observations and brightness scale

We used public Kepler long-cadence brightness measurements of KIC 8719324 and QLP aperture measurements of the same system, listed in the TESS Input Catalog as TIC 185109374. Kepler quarters 1–17 and TESS sectors 14, 15, 41, 54, 55, 74, 75, 81 and 82 supplied 55,289 and 56,045 finite measurements with quality flag zero, respectively. We used barycentric Julian dates (BJD), which refer observation times to the Solar System's center of mass. The Li et al. catalog of binary orbits gives a period of 10.23273940 days and closest approach at BJD 2454962.817390.

We divided the raw aperture flux by its median in each quarter or sector. We fitted cosine and sine coefficients for harmonics 26 and 29 together, excluding measurements within ±0.115 orbital cycles of closest approach. In two-day blocks, we removed a constant and a linear trend from both the data and the fitting functions. We retained blocks with at least eight measurements spanning 0.15 days and iteratively rejected residuals beyond five robust standard deviations.

After subtracting both waves, we grouped the corrected Kepler flux by orbital phase and took the median in each of 500 bins to define the reference pulse. For each quarter or sector we fitted this pulse shape to the wave-subtracted raw flux, excluding ±0.009 cycles around the eclipse at phase −0.045 and using the same local trend removal. Dividing both wave coefficients by the fitted pulse scale corrects for a multiplicative change in pulse response. Using raw flux matters because flattening a brightness record to remove slow trends can suppress the orbital pulse while leaving the fast wave intact.

Eclipse alignment and image measurements

We timed each eclipse in the wave-subtracted raw flux within ±0.014 orbital cycles of phase −0.045. We fitted a quadratic background and a Gaussian dip with free depth and a width fixed at 0.0023 cycles. At trial displacements spaced by 0.0001 cycles over ±0.004 cycles, we calculated the sum of squared residuals for each passage. We scaled each passage's series of sums to span zero to one and added the scaled values at each displacement. The displacement giving the smallest total set the eclipse time for each observing period: Kepler quarters 1–4, 5–8, 9–12 and 13–17, and TESS sectors 14–15, 41, 54–55, 74–75 and 81–82. To align the waves, we rotated the (cosine, sine) point by an angle equal to −2π × 26 times the eclipse displacement in cycles from the reference phase of −0.0455.

For the points in Figure 1, we replaced the sinusoid at harmonic 26 with 12 free bin heights constrained to average zero. For the circular apertures, we obtained 7 × 7 calibrated image cutouts from the TESScut image service. We subtracted each pixel's median, then removed each exposure's median variation beyond 2.8 pixels from the target. We repeated the pulse and wave fits on the summed aperture light using the same eclipse times.

Measurement and forecast errors

For averaging and model fits, we grouped residuals in two-day blocks to estimate the covariance of the cosine and sine coefficients. We used the mean of the two coordinate variances. We combined errors in the pulse scale and eclipse timing in quadrature (adding their variances), estimating timing errors by resampling eclipse passages. We also added error floors of 8 ppm for Kepler and 25 ppm for TESS in quadrature. We weighted measurements by inverse variance to obtain means for each observing period.

To estimate the interval for the phase shift, we held those weights fixed in 50,000 random draws. We perturbed the two original coefficients together using their measured Gaussian covariance, and varied the pulse scale in log space by its fractional error. In each draw we applied one common Gaussian timing shift per observing period, with the standard error from resampling the eclipse passages. We added the TESS error floor to each scaled coordinate as independent noise.

We fitted the beat by weighted least squares to individual quarters and sectors. At each segment's mean observing time, we added a fixed pair of coordinates and a rotating pair, representing each pair as a complex coefficient. Each wave had an amplitude response of one in Kepler and a fitted positive response (0.01–10) in TESS. With our phase convention a faster physical wave rotates clockwise. We scanned frequency differences of either sign up to one cycle per year. At each frequency, allowing unconstrained complex coefficients in each telescope's wavelength range gave a lower bound on the weighted sum of squared residuals. We then optimized the positive response factors. The quoted period range includes grid points within 3.84 of the minimum weighted sum of squared residuals.

To estimate forecast uncertainty, we simulated 1,200 sets of independent Gaussian coordinate errors per model at the observed times using the estimated variances. For each set, we refitted the training data on the long-period branch of the fit and predicted the omitted sectors using their original weights. We compared the measured two-coordinate forecast error with simulated errors, weighting by their inverse covariance. The uncertainties apply to this target, aperture and noise model.