Matching genetic effect estimates resolves conflicting results on body weight and kidney function
You are reading version 1. Read the latest version (3).
- Numbers reproduced
- Yes
- Original conclusion
- Holds
All 12 checked published quantities were reproduced exactly to numerical precision; correcting coefficient compatibility strengthens the BMI–cystatin-C association, but does not establish kidney damage or assess the other adiposity and kidney outcomes.
In plain English
Two genetic analyses appeared to disagree about the link between body weight and a blood test used to assess kidney function because they used mismatched inputs. Making those inputs compatible removed the disagreement and strengthened the link. This shows why conflicting health findings can come from how data are combined, rather than from conflicting evidence about the body.
A mismatch between two kinds of genetic association explains why two methods gave conflicting answers about obesity and a blood-based measure of kidney function. We reconstructed published results linking body mass index (BMI) to kidney filtration estimated from cystatin C. Using BMI effects adjusted for nearby genetic variants alongside unadjusted kidney effects reproduces the disagreement. Replacing the BMI effects with their unadjusted counterparts makes the methods agree. A constructed outcome with no independent genetic pathways produces a similar disagreement when the same mismatch is introduced. Genetic sensitivity analyses can therefore flag an input mismatch that resembles a biological violation of their assumptions.
Results
Mendelian randomization (MR) uses genetic variants associated with an exposure to estimate its effect on an outcome. Inverse-variance weighting (IVW) fits a line through the variant–exposure and variant–outcome associations, constrained to pass through zero. MR-Egger allows an intercept. Under its assumptions, a nonzero intercept can indicate horizontal pleiotropy: variants affecting the outcome through routes other than the exposure.
In Kjaergaard and colleagues’ expanded BMI analysis, IVW suggested lower cystatin-C-based estimated glomerular filtration rate (eGFR), whereas the MR-Egger slope was near zero and its intercept was strongly nonzero [1]. We traced this discrepancy to the BMI input file. The GIANT download supplies both marginal effects (BETA, estimated without adjustment for nearby variants) and conditional/joint effects (BETA_COJO, estimated with such adjustment) [2]. The kidney effects are marginal [3].
Reconstructing the published analysis
The BMI file contains 941 conditionally significant variants. Clumping, which removes variants correlated in a reference population, retained 658 when ranked by conditional BMI P-values. Allele and frequency matching to the kidney data retained 642 for cystatin-C eGFR and 641 for creatinine eGFR, exactly the published counts.
Pairing conditional BMI effects with marginal kidney effects reproduced all 12 checked published quantities: the variant count, IVW slope and standard error, MR-Egger slope and standard error, and Egger intercept for each outcome. The largest absolute discrepancy was below 2 × 10⁻¹⁶ (reconstruction results). This numerical match identifies the coefficient pairing underlying those results; we did not inspect the authors’ analysis code.
Changing only the BMI coefficients
On the fixed 642-variant cystatin-C set, replacing conditional BMI effects with marginal effects changed IVW from −0.03181 to −0.04966 and MR-Egger from −0.00473 to −0.04748. The Egger intercept P-value changed from 1.25 × 10⁻¹⁵ to 0.738. The variants, alleles, kidney associations and outcome standard errors were held fixed.

Figure 1. Coefficient compatibility restores agreement between IVW and MR-Egger. Panel A uses the same 642 variants and observed cystatin-C eGFR effects throughout; bars show estimate ± 1.96 standard errors. Panel B replaces every kidney effect with −0.05 times its marginal BMI effect, retaining the variants and outcome weights. It is a deterministic algebraic control, so only point estimates are shown. With marginal BMI effects both slopes recover −0.05; conditional effects create disagreement.
Table 1. Cystatin-C eGFR estimates per standardized BMI unit, on the log-eGFR scale. The first two rows isolate coefficient choice. The third changes selection as well, requiring marginal genome-wide significance before clumping. See the full estimates and table.
| BMI coefficients and selection | Variants | IVW estimate (95% CI) | MR-Egger slope (SE) | Intercept P |
|---|---|---|---|---|
| Published reconstruction, conditional BMI | 642 | -0.03181 (-0.03631, -0.02731) | -0.00473 (0.00396) | 1.25e-15 |
| Same variants, marginal BMI | 642 | -0.04966 (-0.05490, -0.04441) | -0.04748 (0.00704) | 0.738 |
| Marginal-significance selection, marginal BMI | 565 | -0.04852 (-0.05411, -0.04292) | -0.04647 (0.00794) | 0.782 |
Conditional significance does not guarantee strong marginal associations. Fourteen of the fixed 642 variants had marginal F-statistics below 10, a conventional warning threshold for weak instruments. Requiring marginal P < 5 × 10⁻⁸ before clumping retained 565 harmonized variants, all with F > 10, and preserved the agreement (Table 1).
Creatinine eGFR supplied a second reconstruction target. Its fixed-set IVW estimate changed from −0.00328 to −0.00471, while Egger remained near zero. Thus coefficient replacement preserves the much larger cystatin-C association. The present finding concerns the sensitivity-analysis discrepancy; it does not resolve the biological difference between the two markers.
How the mismatch changes the regression
Let m be marginal BMI effects, c conditional BMI effects and w inverse outcome-variance weights. If outcome effects are exactly proportional to marginal BMI effects, y = θm, IVW using conditional BMI effects returns
This need not equal θ. Allowing an intercept can absorb part of the discrepancy between the coefficient vectors and change the slope further. For example, rs7444298 has a marginal BMI effect of 0.0179 and a conditional effect of 0.124411. Its share of the IVW denominator rises from 0.25% to 7.46%, despite an unchanged kidney association (variant-level results).
We tested this mechanism by setting every outcome effect to −0.05 times its marginal BMI effect. Compatible coefficients recovered IVW and Egger slopes of −0.05 and a zero intercept. Substituting conditional BMI effects gave IVW −0.03285, Egger −0.00831 and intercept −0.0005703 (control results). The observed conditional-coefficient intercept was −0.0006295. This control demonstrates that coefficient mismatch is sufficient to create a similar diagnostic pattern without horizontal pleiotropy by construction. It does not estimate how much biological pleiotropy exists in the observed data.
Methods and reproducibility
We used the public Yengo GIANT BMI file, the Stanzick CKDGen cystatin-C and European creatinine eGFR files, and Supplementary Table S3 of Kjaergaard et al. [1–3]. PLINK 1.9 clumping used a 10-Mb window, r² threshold 0.01 and 503 European 1000 Genomes participants. The reconstruction ranked all 941 candidates by P_COJO; the marginal-significance analysis filtered on P before ranking and clumping.
Harmonization aligned effect alleles and excluded incompatible alleles or frequencies, with no proxy variants. Palindromic variants required both minor-allele frequencies below 0.42 and an allele-frequency match within 0.10; all retained pairs required aligned frequencies within 0.15. We used the kidney files’ original StdErr column, which gives the exact published reconstruction. Earlier analyses using StdErr.GC remain in the repository.
IVW and Egger used inverse outcome-variance weights and multiplicative residual-variance inflation, floored at one. Egger oriented variants toward positive BMI effects separately for each coefficient choice. IVW intervals use ± 1.96 standard errors; Egger intercept P-values use a t distribution with N − 2 degrees of freedom. Exposure standard errors enter the strength diagnostics, not the regression weights. Independent calculations with the R package MendelianRandomization reproduced all final slopes, intercepts and standard errors to within 10⁻¹⁰ (checks).
Interpretation
The cystatin-C IVW–Egger discrepancy is explained by a coefficient mismatch that can be reproduced and removed while holding the kidney data fixed. The practical safeguard is to record the conditioning model alongside each effect allele and coefficient. Conditional analysis can select variants, but substituting its effect estimates into a marginal-summary regression changes the model being fitted.
This audit covers BMI and two eGFR outcomes. Cohort overlap, residual correlation between variants, exposure measurement error and genuine pleiotropy still limit causal interpretation; the intervals are conventional summary-MR intervals. Agreement between IVW and Egger does not validate every instrument or distinguish altered kidney filtration from altered cystatin-C production. The original waist-to-hip ratio, albuminuria, reverse-direction and multivariable analyses require separate examination. Within this scope, compatible coefficients strengthen the estimated BMI–cystatin-C association and remove the sensitivity-analysis conflict that could otherwise be interpreted biologically.
References
- Kjaergaard AD et al. Obesity and kidney function: a two-sample Mendelian randomization study. Clinical Chemistry 68, 461–472 (2022). Article; open text and supplements.
- Yengo L et al. Meta-analysis of genome-wide association studies for height and body mass index in ∼700000 individuals of European ancestry. Human Molecular Genetics (2018). GIANT data and BMI conditional/joint results.
- Stanzick KJ et al. Discovery and prioritization of variants and genes for kidney function in >1.2 million individuals. Nature Communications (2021). CKDGen summary statistics and documentation.