review_outcome: accept

# Review 2

Reviewed on 2026-10-28. I recommend acceptance for human review as a carefully bounded evidence update, not as a definitive causal reversal.

## Assessment

The question is worthwhile, and the revised paper now makes a useful contribution beyond reconstructing the original analysis. Its central comparison updates the cardioembolic outcome while holding the five directly available instruments fixed. That addresses the main weakness identified in review 1. The result is not simply a previously significant estimate becoming nonsignificant: the estimated association becomes substantially smaller despite improved fixed-effect precision.

The paper also treats the original evidence fairly. It distinguishes already published sensitivities from new calculations, restores the supportive historical outlier-exclusion result, and does not substitute ordinary Egger for SIMEX or a changed MR-PRESSO procedure for the original analysis. Those distinctions agree with the [original article](https://doi.org/10.1212/WNL.0000000000007001). The contribution is the matched GIGASTROKE update and its transparent influence analysis, not discovery that the original sensitivities were uncertain.

## What I checked

I ran the documented frozen-environment update command in an isolated temporary copy, leaving the study files untouched. It completed successfully, including the independent R-package checks of all 24 update and leave-one-out fits. I repeated it after removing the copied GIGASTROKE subset, header, index, metadata and cohort workbook. Fresh downloads passed the pinned hashes and reproduced the results. Freshly retrieved original supplement and upstream exposure tables also matched the retained numerical inputs byte-for-byte.

Separately, I recalculated all 24 fits directly from the raw outcome rows and exposure table, aligning to the original signed exposure alleles rather than importing the study's harmonised inputs. Estimates, standard errors, intervals, p-values and heterogeneity statistics agreed within 1e-12. The allele pairs and frequency checks support the five retained alignments, including the required reversal at rs3925584. I independently verified all eight historical primary IVW estimates, reran `main.R`, and regenerated all 28 central magnesium/cardioembolic historical sensitivity rows exactly. I did not complete the remaining phenotype-specific robustness blocks. Ten central regenerated CSV outputs were byte-identical to the saved files.

Key verified results are below; odds ratios are per 0.1 mmol/L higher genetically proxied serum magnesium.

| Analysis | Fixed-effect OR (95% CI) | p |
| --- | --- | --- |
| Historical six-instrument reconstruction | 0.627 (0.494–0.796) | 0.000123 |
| MEGASTROKE, five direct instruments | 0.649 (0.500–0.842) | 0.00115 |
| GIGASTROKE, the same five | 0.865 (0.694–1.078) | 0.197 |
| MEGASTROKE, four excluding MUC1 | 0.848 (0.588–1.222) | 0.376 |
| GIGASTROKE, the same four | 0.991 (0.735–1.336) | 0.952 |
| GIGASTROKE, omit historical TRPM6 outlier | 0.772 (0.607–0.983) | 0.0361 |

These agree with the [primary reconstruction](../results/reproduction_estimates.csv), [update estimates](../results/update_estimates.csv), and [leave-one-out results](../results/update_leave_one_out.csv). The later five-instrument random-effects interval, 0.649–1.152, also reproduces. It remains compatible with appreciable protection, which the manuscript explicitly acknowledges.

The explanatory numbers check out as well. The matched-set log-OR shift is +0.28734, of which the MUC1 ratio change contributes +0.19682 under the stated decomposition order. MUC1 supplies 49.1% of the historical **five-instrument** weight and 45.4% of the updated weight; the manuscript's historical 41.0% correctly refers to the **six-instrument** analysis. The full-set fixed-effect SE decreases from 0.133 to 0.113. Thus attenuation, rather than poorer precision alone, explains the weaker evidence. Neither the decomposition nor deleting MUC1 establishes pleiotropy.

I also independently recounted the [GIGASTROKE supplementary cohort table](https://media.springernature.com/original/springer-static/esm/art%3A10.1038%2Fs41586-022-05165-3/MediaObjects/41586_2022_5165_MOESM4_ESM.xlsx): 10,804 European cardioembolic cases, comprising 6,189 in unchanged cohorts, 718 in updated cohorts and 3,897 in new cohorts. The manuscript correctly avoids converting these into participant-overlap estimates. Its cautions about heterogeneous ascertainment, effective control counts and exposure-cohort overlap are substantive, not boilerplate. An independent-study difference test or a claim of failed replication would be unjustified; the paper makes neither.

## Single most important improvement

The most informative next addition would be the same five-instrument and MUC1-excluded analyses in **nonoverlapping, clinically adjudicated cardioembolic cohorts alone**, with overlap against both the original outcome and exposure samples documented. That would test whether the attenuation persists outside reused participants and changing phenotype composition. It would add more understanding than another collection of estimators applied to these same five SNPs.

This is a next-study priority, not a condition of acceptance here. The current paper already identifies the limitation and keeps its conclusion within the evidence: the later aggregate data weaken support for the original large protective estimate, without establishing no effect, an invalid MUC1 instrument, or any supplementation recommendation. I found no substantive numerical or interpretive defect requiring another revision.
