review_outcome: minor-revisions

# Review 4

The central numerical result holds: accurate MUC1 splice-marker predictions coexist with substantial repeat-spanning length errors, and the matched long-read predictions agree much better with the assembly reference. This is a useful, bounded contribution for scientists choosing measurements for joint SNP–repeat analyses. It does not establish why the magnesium instrument associates with stroke, and the paper makes that distinction clearly. I recommend minor revisions, principally to make the validation advice more specific using an already available result.

## Checks performed

I reran `run_technology.sh`, `run_update.sh`, `run_repeat_audit.sh` and `run_mvp_finemap.sh` in a temporary study copy with the frozen project environment. All completed, including the supplied R checks; the manuscript table check also passed. The regenerated result files were byte-identical to the retained files. This was a cached-input replay, not a cold download or a fresh Locityper run.

Separately, I wrote a scratch calculation without importing the study's analysis functions. Starting from the compressed FASTA and archived genotype predictions, I re-extracted both length anchors and the splice base, restored the documented identical-sequence alias, and rebuilt all 248 predictions. Their reference lengths, predicted lengths, errors and splice dosages matched the retained individual-level data exactly. The principal Illumina leave-one-out results reproduce: 39/40 correct dosages, 24/39 large length errors among correct dosages, median absolute error 2,001 bp, mean signed error −1,346 bp and prediction R² −0.58662. The matched 17-person medians of 2,112, 15 and 19 bp also reproduce.

The pipeline checks reproduced all 24 stroke update/exclusion fits, 252 repeat-audit fits, and the fine-mapping extraction. The matched five-instrument stroke estimates are 0.649 (0.500–0.842) and 0.865 (0.694–1.078). I did not independently rebuild the original GWAS or establish biological sequence truth. The manuscript does not allege an original calculation error; its interpretation of attenuation in overlapping newer cohorts is appropriately limited.

## Single most important improvement

Bring the splice-genotype-specific length errors into the Results. Review 3 requested this, but the current manuscript still leaves it as advice for future validation. My independent reconstruction confirms the pattern:

| Reference rs4072037 T dosage | n | Correct predicted dosage | Mean signed error, bp | Median absolute error, bp | Errors >600 bp |
| --- | --- | --- | --- | --- | --- |
| 0 | 3 | 2 | −2,443.3 | 2,270 | 3 |
| 1 | 21 | 21 | −2,107.2 | 2,164 | 20 |
| 2 | 16 | 16 | −141.1 | 107.5 | 2 |

All 21 heterozygotes have correct splice dosage, yet 20 have large length errors. That matters directly to the proposed joint analysis: measurement errors are not uniform across the genotype on which the analysis would condition. The matched long-read comparison makes this more informative. Among the nine heterozygotes with all three read inputs, median absolute errors are 2,288 bp for Illumina and 19 bp for both HiFi and ONT; errors above 600 bp number 9, 1 and 0. Among the seven matched two-T participants, the corresponding medians are 60, 14 and 17 bp, with counts 1, 1 and 0. The remaining matched participant has zero T copies.

Add a compact table or figure showing this contrast. Keep it descriptive: genotype, actual length and ancestry covary, and the smallest group cannot support inference. These results neither show that the splice allele causes the errors nor predict the direction of bias in an unobserved magnesium analysis. They do strengthen the practical recommendation to validate length within splice-genotype groups. This is a focused addition to the existing claim, not a demand for a new biological study.

## Contribution, presentation and record

State explicitly what the source studies already established. In the retained full text of the [Plender preprint](https://doi.org/10.64898/2026.07.01.26356476), the authors report poor MUC1 haplotype-level concordance and exclude MUC1 from models requiring precise length estimates, while retaining haplogroup analysis. The [Locityper paper](https://www.nature.com/articles/s41588-025-02362-4) already compares short reads, long reads and assembly-derived simulations. The contribution here is therefore the endpoint-specific splice-versus-length discrepancy, its relevance to the two candidate SNPs, and the matched length and availability analyses—not discovering generally that MUC1 is difficult to genotype. One short paragraph would make that distinction clear without expanding the paper.

The paper is otherwise readable outside MR: it defines the important terms and gives concrete effect sizes. The long-read comparison is correctly described as agreement with an imperfect reference rather than independent validation; the availability search is correctly separated from an achievable predictor. Preserve those boundaries. I would not require a molecular explanation of stroke to publish this narrower measurement result.

`record.json` is fair. `type: reproduction` fits this version-specific reanalysis; `numbers: partly` with `our-limits` distinguishes an approximate reconstruction from an accusation of error. `conclusion: weakened` with `newer-data` fits the outcome update and does not mean protection has been disproved. The five-sentence `so_what` explains the progression in ordinary language and explicitly avoids supplement advice. I found no material numerical or interpretive defect warranting major revision.