# Review 1: "Growing lung nodules usually closed more of the gap than nearby traceable vessels did"

**Recommendation: major revisions.** The numbers reproduce from the saved tables and the measurement design is careful. But the headline comparison is mostly built in by how the nodules were chosen. The paper also sets aside a small, consistent inward vessel shift as repeat-scan noise, and its own large control group contradicts that reading. Fixing this needs only reanalysis of tables that already exist and some rewording, but it changes what the paper says about vessels.

## What the paper claims

For enlarging, cancer-labelled LUNA25 nodules, the authors measured vessel-like segments that could still be traced and stayed at least 4 mm from the nodule on both scans. They split the narrowing of the nodule–vessel gap into a part due to the border advancing and a part due to the vessel moving sideways. Edge advance was larger in 13 of 16 people (medians 1.65 vs 0.23 mm). The paper reads the 0.23 mm as within the range seen on same-day RIDER repeat scans, and concludes that the vessel is largely stationary and the edge does most of the closing.

## What I checked

Working from `results/`, I confirmed:
- the cohort flow (`cohorts.csv`: 207 → 129 → 72 → 33 intervals → 67 segments → 27 traced → 25 clear, 17 intervals, 16 people);
- Table 1 person-level medians and win counts, and the Clopper–Pearson intervals (54–96%, 59–100%);
- 24 of 25 segments closing, with baseline midpoint gaps of 8.1–15.5 mm;
- lost vs traced path clearance (2.37 vs 7.38 mm; 10 vs 1 within 1 mm);
- the disc readout (30 paths, 17 people, 15 of 17 wins, 1.77 / 0.19 mm);
- the denser-border and remote-frame sensitivities (19 segments in 15 people at 1.71 / 0.21 mm; 14 people at 1.83 / 0.26 mm);
- the imposed-shift retention (27/26 and 25/22);
- the six RIDER segments (motion −0.19 to +0.29 mm).

I also read the decomposition in `analysis/sections.py`. It is a symmetric two-order average, so the two parts add up to the measured closure, as stated. I did not rerun the CT pipeline, but the reported numbers match the saved outputs.

## Main issues

### 1. The headline comparison could hardly have come out the other way

Nodules were picked because their equivalent radius grew by at least 1 mm, and the measured vessels sat 8–15 mm from the border. For vessel motion to beat edge advance, a vessel about 1 cm away would have to move more than 1 mm toward the nodule relative to an affine frame fitted at 18–28 mm. The paper says that selection "does not require the side facing a vessel to advance". That is true for a single side, but on average it does require it. So "13 of 16" and "7 of 7" mostly confirm the selection rule. The non-cancer transfer cohort repeats the same near-automatic comparison in seven people, so it adds little evidence that could have failed.

The comparison that could have failed is whether vessels move inward more near growing nodules than in a no-growth reference. That is the question in the study's title, and the data to answer it are already in the paper (point 2).

### 2. The paper's own data contradict reading the vessel shift as noise

From `results/patients.csv`, using person-level medians of the midpoint motion contribution:

| Group | People | Median motion (mm) | People with inward motion |
|---|---:|---:|---:|
| Enlarging, cancer | 16 | 0.23 | 14/16 |
| Stable, cancer | 10 | 0.21 | 9/10 |
| Enlarging, non-cancer | 7 | 0.13 | 5/7 |
| Stable, non-cancer | 173 | −0.004 (IQR −0.10 to 0.08) | 84/173 |

- Near enlarging cancer-labelled nodules the inward shift is consistent: 14 of 16 people are positive, and a Wilcoxon signed-rank test against zero gives p ≈ 0.001.
- It differs from the 173-person stable non-cancer reference (Mann–Whitney p ≈ 1e-5). Pooling all enlarging against all stable people gives p ≈ 5e-5.
- It does not differ from stable cancer-labelled nodules (p ≈ 0.6), which show the same roughly 0.2-mm inward shift without growth.

The paper calls 0.23 mm "within the range seen on repeat acquisition", based on six RIDER segments. A 173-person reference measured with the same LUNA25 pipeline is a far better null than six RIDER segments, and it is centred on zero. The data therefore point to one of two things:
- a small but real inward displacement near cancer-labelled nodules, whether or not they grow; or
- a measurement bias specific to these nodules or images. For example, a density-weighted vessel centre could be pulled toward nodule-side tissue in part-solid or ground-glass cancers. Slice thickness, lobe or interval length could also differ between groups.

Either answer is more informative than "within noise". The RIDER range should not carry this interpretation.

**Requested** (no new data needed):
- Report the motion contribution by group, with person-level tests against zero and against the stable non-cancer reference.
- Run at least one check that could expose a method bias:
  - swap visit order and confirm the sign flips;
  - compare segments on the far side of the axis from the nodule against the near side;
  - compare slice thickness, interval length and nodule density (`core_hu.csv`) across the groups.
- Then state plainly what is left. If a consistent sub-millimetre inward shift survives, that is the finding about vessels, and the title and summary should say so. If it is explained away, say how.

Record finding #3 and the RIDER paragraph should change either way.

### 3. "Nearby" and "before reaching" overstate what was measured

The question asks what happens before a nodule reaches a vessel. The measured segments were 8–15 mm from the border, and the paths closest to the later border were the ones lost to tracking (40 of 67). The paper states both facts. But the title ("nearby traceable vessels") and the summary present the result as being about the approach to contact. It is about vessels about a centimetre away. Put the distance in the title or first paragraph, for example "vessels 8–15 mm away".

## Clarity

The paper is mostly readable. Two passages get in the way:
- The second paragraph of "Measuring both sides of the gap" reports scout results: the "21 intervals… divided by two, 0.23 mm" figure, and 25 of 29 people under a point-matching method the paper then explains is unreliable. A reader cannot tell which numbers count. Cut this to one sentence saying a cruder point-matching scan suggested the question, and give how much was scanned.
- "Transported planes", "equivalent radius" and "compact border" need a short plain definition at first use in the main text, not only in Methods.

The two exemplar cases (213544, 211965) are well handled and show the method's value. Keep them.

## record.json

- `so_what` is fair as written. It may need softening if point 2 shows a real inward shift, because "the vessel was not pulled" would then be only partly true.
- Finding #3 ("encompassing the 0.23-mm median") should be replaced, for the reasons in point 2.
- Importance 2 is reasonable.

## Most important change

Replace "edge > motion", which the selection rule largely guarantees, with a direct test of vessel motion against the 173-person stable reference, plus one bias check. Then report what that shows: either a consistent sub-millimetre inward shift near cancer-labelled nodules, or an identified artifact.
