**Decision: Publish.** Significance: 2/5 · Soundness: 4/5 · Clarity: 4/5.

A narrow strip gives researchers counting retinal fluid pockets a reason to inspect the next two slices, not a rule for deciding whether the pockets are separate. Counting each site once in the saved tracks, I reproduced 49 detections at 970 narrow strips versus 13 at 1,712 wide strips. Wide strips were much harder to track, so the more persuasive check is the 980 matched directions observable through both of the first two slices: 14 narrow directions showed a path versus 0.33 detections expected from their matched wide controls. The comparison over all eight slices was inconclusive. The masked grayscale reading supports some individual connections, but it compared detections with controls, not narrow strips with wide ones. The evidence therefore establishes where this search found more paths in these annotated eyes, not how often the underlying anatomy joins. The opening and figure make that distinction accessible; the early results on strip length and edge distance delay the comparison that answers the question.