# Skipping human reading of mammograms labeled normal by AI would lose one invasive cancer detection per 9,681 examinations spared

Breast-screening services could reduce reading work by automatically clearing mammograms that artificial intelligence (AI) labels normal. The question is how many cancers human readers would otherwise find in those examinations. Detecting more cancers than screening without AI does not settle whether readers can be removed from a service that already uses AI.

In a simulation using PRAIM, a study of AI use in routine mammography screening, automatically clearing AI-normal examinations would remove 16 invasive cancer detections while sparing 154,891 examinations from human reading. Invasive cancers have spread into surrounding breast tissue. The loss is 1.03 invasive detections per 10,000 examinations spared (95% confidence interval, 0.59–1.68), or one per 9,681. The simulation retains 98.8% of the invasive cancers detected by the observed AI-assisted workflow.

## Background

PRAIM prospectively observed mammography screening at 12 German sites in 2021–2023, with radiologists choosing whether to use AI. A screening examination comprises images assessed independently by two readers, a process called double reading. Suspicious findings can lead to a consensus conference, where readers discuss the examination, a recall for further assessment and a biopsy recommendation. A normal AI tag identifies an examination the algorithm considers highly unsuspicious; it does not establish the absence of cancer. [PRAIM archive documentation](https://zenodo.org/records/13952914)

Eisemann and colleagues found higher adjusted cancer detection with AI-assisted double reading than with unaided double reading. PRAIM's scale and routine-care setting make it an important source of evidence about screening implementation. The authors also simulated automatically clearing AI-normal examinations. Cancer detection remained 16.7% higher than with unaided screening, although the simulation removed 20 cancers that readers had detected in AI-normal examinations. [Eisemann et al., 2025](https://doi.org/10.1038/s41591-024-03408-6)

We rechecked that simulation and calculated the loss of invasive detections per examination spared, compared with retaining the observed AI-assisted readers. We distinguish invasive cancers from ductal carcinoma in situ (DCIS), which is confined to the breast ducts. We also examine the tradeoff by screening site and breast density, the relative amount of fibrous and glandular tissue visible on a mammogram.

## Results

### The simulated saving removes 16 invasive detections

Clearing all AI-normal examinations would spare 59.40% of the observed AI-assisted cohort and remove 1.22% of its invasive detections. The cohort contains 260,739 examinations, of which 154,891 were tagged normal. Among these were 16 invasive cancers, one DCIS and three cancers classified as other. The simulation therefore retains 1,292 of 1,308 invasive detections and 1,659 of 1,679 cancer detections overall.

Table 1. Outcomes removed when every AI-normal examination in the observed AI-assisted cohort is cleared automatically. Counts are unweighted. “Removed” means that an observed outcome is suppressed in the simulation; it does not predict the woman's subsequent clinical course.

<!-- table1 -->
| Quantity | Result in the observed cohort |
| --- | --- |
| AI-assisted examinations | 260,739 |
| Examinations spared human reading | 154,891 (59.40%) |
| Invasive detections removed / retained | 16 / 1,292 |
| DCIS detections removed | 1 |
| Other cancer detections removed | 3 |
| Invasive detections removed per 100,000 total examinations | 6.14 |
| Recalls removed | 1,905 |
| Biopsy recommendations removed | 82 |
| Consensus conferences removed | 8,032 |
<!-- /table1 -->

The invasive loss is 6.14 detections per 100,000 examinations entering this workflow, or 1.03 per 10,000 examinations spared from reading. The first rate describes the loss across everyone screened; the second describes the loss for the reading work saved. The 1,905 recalls and 82 biopsy recommendations removed include workups that led to cancer diagnoses; they cannot all be counted as unnecessary procedures avoided.

Cancer grade describes how abnormal the cells look, while stage describes how far the disease has spread. Fourteen of the 16 removed invasive cancers were grade 2 or 3. Seven measured at most 10 mm, six measured 10–20 mm and three exceeded 20 mm. Eleven were stage 1, three were stage 2 and two had undetermined stage. The removed detections therefore include invasive disease beyond the smallest and lowest-grade lesions.

### Losses by screening site and breast density

Dense and nondense breasts have similar estimated invasive losses per examination spared, but only 16 events inform all subgroup comparisons. Dense breasts account for six removed invasive detections among 50,951 spared examinations, or 1.18 per 10,000. Nondense breasts account for ten among 103,940, or 0.96 per 10,000. The fractions spared differ: 53.66% and 62.87%, respectively.

Table 2. Invasive detections removed per examination spared, by site and recorded density. The intervals are adjusted so that, under the binomial model described in Methods, they cover the rates for the 11 contributing sites and two density groups together with at least 95% confidence. Sites and density groups overlap; their counts must not be added together. The 452 examinations with missing density had no AI-normal tags and provide no estimable loss rate per spared examination.

<!-- table2 -->
| Group | Spared examinations | Invasive detections removed | Removed per 10,000 spared | Simultaneous 95% interval |
| --- | --- | --- | --- | --- |
| Site 01 | 11,698 | 0 | 0.00 | 0.00–5.34 |
| Site 02 | 12,662 | 2 | 1.58 | 0.05–8.24 |
| Site 03 | 22,114 | 3 | 1.36 | 0.11–5.53 |
| Site 04 | 14,915 | 0 | 0.00 | 0.00–4.19 |
| Site 05 | 3,914 | 0 | 0.00 | 0.00–15.97 |
| Site 06 | 8,683 | 1 | 1.15 | 0.002–9.79 |
| Site 07 | 33,367 | 6 | 1.80 | 0.38–5.13 |
| Site 08 | 18,970 | 1 | 0.53 | 0.001–4.48 |
| Site 09 | 11,972 | 1 | 0.84 | 0.002–7.10 |
| Site 10 | 11,749 | 2 | 1.70 | 0.05–8.89 |
| Site 11 | 4,847 | 0 | 0.00 | 0.00–12.89 |
| Dense | 50,951 | 6 | 1.18 | 0.25–3.36 |
| Nondense | 103,940 | 10 | 0.96 | 0.31–2.22 |
<!-- /table2 -->

Site 07 contributes six of the sixteen events and the largest number of spared examinations. Tests for differences in loss rates found no detectable variation across sites (conditional Monte Carlo P = 0.701) or density groups (Fisher P = 0.791). Adjusting for these two tests with the Holm method gives both P values as 1.00. With so few events, the tests cannot establish that the tradeoff is uniform. Even Site 04, the most precise zero-event site, has a simultaneous upper confidence bound of 4.19 invasive detections per 10,000 spared examinations. No site can be identified here as having zero detection cost.

### The published comparison with unaided screening reproduces

All four outcome comparisons and confidence intervals in the original paper's Table 5 reproduce to published rounding using the authors' main statistical weights. These are reader-set overlap weights: a reader set is the combination of radiologists reading an examination, and overlap weighting emphasizes examinations whose reader set and AI prediction make either AI-assisted or unaided reading plausible. Rebuilding the weights from the original predictor variables gives the same results as the supplied main weights.

Table 3. Reconstructed weighted comparison of automatic clearance of AI-normal examinations (simulated autonomy) with unaided screening, using independently rebuilt weights. These are all-cancer and workflow outcomes in the weighted comparison population, separate from the raw invasive-cancer accounting in Tables 1–2.

<!-- table3 -->
| Outcome | Simulated autonomy, per 1,000 | Unaided screening, per 1,000 | Relative difference (95% confidence interval) |
| --- | --- | --- | --- |
| Cancer detection | 6.650 | 5.698 | 16.72% (4.90 to 29.87) |
| Consensus conference | 89.521 | 111.133 | -19.45% (-21.46 to -17.38) |
| Recall | 32.590 | 38.322 | -14.96% (-18.60 to -11.15) |
| Biopsy recommendation | 10.134 | 9.581 | 5.77% (-2.72 to 15.00) |
<!-- /table3 -->

With the same weights, observed AI-assisted cancer detection is 6.700 per 1,000 examinations and simulated autonomous detection is 6.650, compared with 5.698 for unaided screening. The two comparisons are thus compatible: simulated autonomy retains an advantage over unaided screening while giving up detections made by AI-assisted readers.

The archived analysis for the original Table 5 selects weights based on individual readers, whereas the published table and its stated main model match weights based on reader sets. The supplied individual-reader weights produce a cancer-detection contrast of 18.03%, compared with the published 16.72%. This discrepancy concerns which archived input reproduces the table; it does not overturn the original advantage over unaided screening.

## Interpretation

The incremental decision represented by PRAIM's simulation exchanges about one known invasive cancer detection for every 9,681 examinations spared from human reading. It also removes substantial assessment work. Whether that exchange is acceptable requires a judgment about detection, patient outcomes and staffing that superiority to unaided screening alone cannot settle. Of the published 20-cancer loss, the invasive detections provide a direct measure of the detection cost per examination spared, with uncertainty about how that cost varies between groups.

These are screen-detected cancers. Without follow-up for cancers diagnosed between screening visits, the data cannot estimate all cancers missed, the consequences of delayed diagnosis or mortality. The simulation assumes unchanged outcomes on examinations that retain human readers; actual reader responses to an autonomous workflow are unobserved. Because radiologists chose whether to use AI, the results may not generalize beyond this cohort. The uncertainty calculations assume independent examinations at the observed sites. Examinations spared are neither individual reads nor measured time saved. They cannot be converted directly into a percentage reduction in staffing or reading time.

## Methods

### Data and fixed-cohort accounting

We used the examination-level data embedded in the authors' public Zenodo archive, version 1.3.0, record 13952914, verifying its published checksum and archive integrity. The table contains 461,818 unique examination identifiers and 26 columns, including supplied weights. We selected all 260,739 examinations recorded as AI-assisted and used the supplied normal-tag, cancer, invasiveness and workflow classifications without reclassification. [PRAIM data and analysis archive](https://zenodo.org/records/13952914)

For each examination tagged normal, we set the observed cancer-detection, recall, biopsy-recommendation and consensus-conference outcomes to zero. All other examinations retained their observed outcomes. We counted invasive detections from the recorded invasiveness category and verified that each also had a positive cancer-detection indicator. We divided removed invasive detections by normal-tagged examinations for the workload tradeoff, and by all AI-assisted examinations for the population loss. These counts and rates give each examination equal weight. The exact cohort counts require no sampling estimate; intervals describe uncertainty when generalizing their rates under repeated independent examinations.

### Subgroups and uncertainty

Site and density were specified as subgroups using the data structure and published overall counts, without inspecting subgroup outcomes. We included every site contributing AI-assisted examinations and both recorded density categories, retaining missing density separately. Eleven of the archive's twelve sites contributed to this cohort. The analysis retained the original normal-tag rule and all eligible sites.

The overall rate uses a two-sided Clopper–Pearson exact binomial 95% confidence interval, which treats each spared examination as an independent trial with or without a removed invasive detection. Subgroup intervals use a Bonferroni correction across the 13 categories with nonzero spared denominators, giving each interval confidence level 1 − 0.05/13. This gives the stated confidence level for all group intervals together despite overlap between the site and density groups. Missing density has zero spared examinations and no rate interval.

For the site test, the null hypothesis is an equal probability of a removed invasive detection per spared examination. We conditioned on the 16 total events and the site denominators, allocating events without replacement under a multivariate hypergeometric distribution. We measured departures from equal rates with the Pearson statistic over 200,000 random (Monte Carlo) allocations, using random seed 20261030 and adding one to the extreme and total replicate counts. The Monte Carlo standard error is approximately 0.001. Density was tested with a two-sided Fisher exact test on invasive events versus other spared examinations. Holm correction covered these two heterogeneity tests.

### Reproduction of the published weighted analysis

We estimated the probability of AI-assisted reading using logistic regression, with reader set and the presence or absence of an AI-normal tag as predictors. We grouped examinations with identical predictor values into binomial counts. This preserves the model likelihood while avoiding a large examination-level design matrix. We assigned AI-assisted examinations weight one minus their fitted probability and unaided examinations weight equal to that probability, then normalized within each group. The model converged despite near-zero and near-one fitted probabilities; the maximum absolute difference from supplied normalized main weights was 2.41 × 10⁻¹³.

For the Table 5 simulation, we suppressed normal-tagged outcomes only in the AI-assisted group. We estimated weighted group means using the HC3 heteroskedasticity-consistent variance estimator, which allows variance to differ between observations and adjusts for their influence on the fit. We treated weights as fixed to match the original analysis. Absolute differences used normal-distribution intervals. Relative differences used the delta method, a variance approximation, to calculate intervals on the logarithm of the ratio; these were transformed back to percentage differences. We repeated the calculations using supplied individual-reader weights to identify the archive mismatch. Analyses used R 4.4.3.

## References

Eisemann N, Bunk S, Mukama T, et al. Nationwide real-world implementation of AI for cancer detection in population-based mammography screening. *Nature Medicine* 31, 917–924 (2025). [doi:10.1038/s41591-024-03408-6](https://doi.org/10.1038/s41591-024-03408-6).

Eisemann N, Baltus H. Code & supporting documents for “Nationwide real-world implementation of AI for cancer detection in population-based mammography screening (PRAIM).” Version 1.3.0 (2025). [Zenodo record 13952914](https://zenodo.org/records/13952914).
