# Review of "Urinary vesicle proteins enriched in post-exam collections tend to be lower in prostate cancer than in benign enlargement"

**Recommendation: minor revisions.** The benchmark recheck is exact and the main observation is real. The P20 cancer-minus-BPH protein differences run opposite to the pre-to-post-exam change seen in five paired men, and a score built without diagnoses separates cancer from BPH. The section on which differences repeat needs a control, though. Without one, Table 1 reads as evidence about the collection axis in particular. My control shows it is not: adjusting for any good proxy of diagnosis produces the same drop.

## What I checked

- **Reproducibility.** I copied `analysis/` and `data/` to a scratch directory, verified the checksums and ran `recheck.py` and `display.py`. Every output table (`benchmark`, `scores`, `four_refit`, `matched`, `proteins`, `signature`, `subjects`, `whole`, `outside_score`, `effect_rank_intervals`, `pair_flips`, `agreement.md`) matched the committed files byte for byte.
- **Benchmark.** The validation P20 median differences match the published Figure 6C values to machine precision. The discovery values agree within 0.17 log₂ units. Integrating the deposited curves gives AUCs of 0.9283 and 0.8080. The `numbers: partly / our-limits` verdict is fair: the predictions themselves were not rebuilt, and the paper says so plainly.
- **Main numbers.** All the text figures I checked match the outputs: 767/943 opposite in validation, collection-score AUCs of 0.910, 0.830 and 0.597, refit AUC 0.835, correlations of 0.78/0.60/0.80, the adjusted log-odds gap 2.53→0.52, 8 matched pairs with 6 concordant, the 0.69→0.27 and 0.59→0.27 drops, and the whole-urine correlations of 0.81 and 0.06.

## Main issue: the Table 1 drop is not specific to the collection axis

The paper regresses each protein on diagnosis with and without the collection score. Discovery–validation rank agreement then falls from 0.69 to 0.27, and Table 1 and the record present this as evidence that the reproducible pattern follows the collection axis. The check on the 743 proteins outside the score answers a different worry, that the score's own ingredients drive the drop. It does not answer the obvious one. The score has an AUC of 0.83–0.91 for diagnosis, so adjusting for it partly adjusts for diagnosis. Any covariate that strongly tracks diagnosis should then remove most of the shared between-panel pattern, whatever it measures.

I tested this with the study's own `fit` and `scores` functions on the same 943 proteins and scorable patients (script in my scratch directory; easy to re-create). Agreement between panels after adjusting for different covariates:

| Covariate | D–V | D–Ghent | V–Ghent | Covariate AUC (D, V, Ghent) |
|---|---:|---:|---:|---|
| none | 0.69 | 0.44 | 0.37 | — |
| collection score (paper) | 0.27 | 0.06 | −0.06 | .91, .83, .60 |
| four-marker refit logit (4 proteins, none in the score) | **0.21** | — | — | .97, .83 |
| discovery-trained disease score, top vs bottom 100 by discovery difference | **0.17** | −0.02 | −0.02 | .97, .83, .60 |
| first principal component within each panel (no labels) | 0.37 | 0.05 | −0.02 | .87, .79, .62 |
| three random 100-vs-100 protein scores | 0.55–0.74 | 0.41–0.49 | 0.30–0.40 | .55–.73 |

Adjusting for the four published markers' own prediction lowers discovery–validation agreement as much as the collection score does. A score trained directly on discovery diagnoses lowers it further. So the drop in Table 1 says the shared disease pattern lies along one dominant axis. It does not show that the axis is a collection effect rather than disease. The evidence that this axis is the collection axis is elsewhere:

1. The protein-level correlation of −0.70 between the paired change and the disease difference.
2. The fact that a score built without labels lands on it. I also find that the unsupervised first principal component of each panel correlates 0.79, 0.90 and 0.95 with the collection score in discovery, validation and Ghent.
3. The tight link to prostate protein share in whole urine.

**Request.** Add this control, or an equivalent one, to Table 1 or its text. Reword the section so the drop is described as what you would expect after adjusting for a strong diagnosis proxy. The fourth bullet of `findings` in `record.json` and the last sentence of `summary` should change to match. The FDR result can stay: no protein replicates individually in both validation panels, even without adjustment. That is a useful negative and is already stated honestly.

## Other points that would strengthen the paper

**Report the exact sign-flip test, which the code already computes.** `pair_flips.tsv` flips the direction of each of the five donors' changes, giving 32 orientations. The observed orientation gives the most negative correlation in all three panels, so the exact one-sided P is 1/32 ≈ 0.03, the smallest possible with five men. Six orientations still give ρ ≤ −0.56. One sentence would show that the paired axis is consistent across donors and that five men set the limit on how strong the evidence can be.

**Use the out-of-scan whole-urine test, and report both whole-urine results.** The Italian cohort was not among the 16 P20 contrasts in the scan. It is the cleanest test that could have refuted the headline pattern, and the paper uses it only to interpret the score. I computed the cancer-minus-BPH median differences in that cohort and correlated them with the paired P20 change. The correlation is −0.30 on the 504 proteins of the 943-set measured in ≥50% of specimens, with 63% opposite in sign. It is −0.30 on 371 proteins at ≥80% coverage. That is modest, out-of-scan support for the title claim and worth one sentence.

The same cohort also shows something the paper omits:

- `whole.tsv` gives a collection-score AUC of only 0.59 for cancer vs BPH in the 61 scorable specimens.
- The prostate-protein index itself barely separates the groups: AUC 0.55 for lower values in cancer, across all 133 specimens (my calculation).

So in the one cohort where prostate protein share is measured, it carries little diagnostic signal. This does not undercut the P20 result. It does bear on the closing interpretation, that the P20 cancer signal partly reflects sample composition, and on the `so_what` line that the markers may pick up "how much of the urine's protein comes from the prostate". Please report both AUCs. Keep the composition interpretation framed as specific to P20 and Khoo's protocol.

**A biological lead the paper could mention.** SLC4A1 (band 3) has the largest marker effect and falls 1.4 log₂ units between collections. It is an erythrocyte membrane protein, and HBB and HBA1 also fall after the exam. If cancer specimens contain relatively more blood-derived vesicle protein, that alone could produce part of the pattern. One sentence, or a quick check of a red-cell protein set against the score, would help a reader understand what the axis is.

## Clarity

- The opening paragraph and the "published benchmark" section are clear. It is unmistakable that the paper does not claim the original is wrong: "The original finding … holds."
- Table 1's caption should say what "after adjustment" means (diagnosis coefficient with a linear collection-score term) without sending the reader to Methods.
- "Validation 1" appears only in the code, which is fine. "iBAQ" is defined. The Methods are dense but complete enough that I could follow the code from them.
- The scan is disclosed: 16 contrasts, and both P20 disease panels were part of it. Please also say that the Ghent and Italian data were examined in the scouting stage. The notes say the Ghent AUC of 0.60 and a retargeted whole-urine score were seen. Then the reader knows which tests were fully blind. Only the prospective score AUC was blind with respect to the score, and even that panel contributed to the scan's correlation.

## record.json

- `type: reproduction` and the verdict (`numbers: partly`, `our-limits`; `conclusion: holds`) fit the evidence.
- `so_what` is readable and does not mislead about the original test. Its last sentence should be softened in line with the whole-urine AUCs above.
- `findings` bullet 3 needs the change described under the main issue.

## Single most important improvement

Add a control covariate that tracks diagnosis but not collection, such as the four-marker logit, next to the collection score in Table 1. Then rewrite that section to say the drop reflects one dominant shared axis. The evidence that this axis is collection-related comes from the paired-change correlation, the sign-flip test and the out-of-scan whole-urine correlation, not from the drop in agreement.