# After five doses of ranolazine, the heart’s late electrical recovery took longer than first-dose data predicted

Drug researchers use a single dose to measure how the heart’s electrical recovery changes as the blood level of a drug rises. To predict recovery after several doses, they need to know whether the same relationship still applies. In ten healthy volunteers taking ranolazine, a drug used to treat chest pain, the late part of recovery lengthened by 21.3 milliseconds (ms) from the first dose to the fifth, relative to placebo. Starting with each person’s first-dose heart tracing and accounting for the measured rise in ranolazine level predicted an increase of only 6.8 ms. The average shortfall was 14.5 ms (exploratory 95% interval 7.0–21.5). The earlier part of recovery showed no corresponding excess.

## What the heart tracing measures

An electrocardiogram (ECG) records the electrical activity of the heart. Its QT interval measures the time from the start of electrical activation in the ventricles, the heart’s pumping chambers, to the end of their recovery. The end of activation is called the J point. From there to the peak of the T wave is the early recovery interval; from that peak to the end of the wave is the late interval. Two drugs can lengthen QT by the same amount yet affect different parts of recovery. Ranolazine blocks both outward potassium current and inward late sodium current. In a single-dose study, [Johannesen and colleagues](https://doi.org/10.1038/clpt.2014.155) found that ranolazine lengthened mainly the late interval.

In the [Comprehensive in Vitro Proarrhythmia Assay (CiPA) ECG validation trial](https://doi.org/10.1002/cpt.1303), ten volunteers took 1,500 mg of ranolazine after breakfast and again in the evening on days 1 and 2, then a fifth dose after breakfast on day 3. Vicente and colleagues estimated that the late interval lengthened by 11.9 ms at the day-1 peak concentration and by 25.7 ms at the higher day-3 peak. Both the dose number and the peak blood level changed. How much of the difference could the rise in the concentration of ranolazine itself (the parent drug) explain using the first-dose response?

## Comparing the first and fifth doses at the same hour

We first looked for occasions when the same person had similar drug levels on both days. Across five regimens and six ECG measures, one pattern stood out: all ten ranolazine recipients had a longer late interval on day 3 than on day 1 at their closest pair of positive concentrations, after subtracting changes on placebo. But some day-1 readings followed the evening dose. When we used only readings after the first dose, nine people had a day-3 level within a factor of 1.25. Eight had a longer late interval (median change across nine, +7.1 ms). Only two people had levels that close within two hours of the same scheduled time, and none did at the same hour.

We therefore compared readings taken at the same hour and predicted how much the difference in drug level should change each interval. Days 1 and 3 had six scheduled readings in common, from half an hour to four and a half hours after the morning pill. A separate single-dose crossover trial, in which 22 volunteers received 1,500 mg of ranolazine and also received placebo on another occasion, supplied the expected change in each interval per unit rise in concentration (the single-dose slope). For each recipient at each hour, we multiplied that slope by the rise in concentration to predict the change from their first-dose ECG. All comparisons below subtract the change among placebo recipients at the corresponding times.

The rise in concentration averaged 2.02 micrograms per milliliter (µg/mL). The single-dose slope for the late interval was 3.39 ms per µg/mL. It underestimated the change at every scheduled hour (Figure 1) and for all ten recipients when we averaged each person’s six readings. The late interval lengthened by 20.7 ms on ranolazine and shortened by 0.6 ms on placebo. For the early interval, adjusted for heart rate, the mean change relative to placebo was −4.4 ms against a prediction of +0.4 ms. The error (observed minus predicted) was −4.9 ms (95% interval −13.5 to 3.8), with no clear difference in either direction. For heart-rate-corrected QT as a whole, the observed and predicted changes were +18.9 and +8.6 ms.

![Observed and predicted changes in late recovery, early recovery and QT at six times after the morning dose](results/clock-profile.png)

Figure 1. Each point averages the same ten recipients. Solid lines show the placebo-adjusted change from day 1 to day 3. Dashed lines show the change predicted from each person’s rise in ranolazine concentration and the single-dose slope for that interval. The shortfall for the late interval was largest half an hour after the pill (27.2 ms).

We also estimated slopes using the first dose in the repeat-dose trial itself. A common slope fitted to the readings after breakfast was steeper (5.34 ms per µg/mL) and reduced the mean error for the late interval to +10.5 ms. Fitting a separate slope for each recipient gave a mean error of +9.4 ms, positive in six of ten. Restricting the comparison to pairs with heart rates within 3 beats/min of each other left 32 pairs from all ten people. With the slope from the separate single-dose trial, the mean error was +11.6 ms (−1.3 to 22.8), consistent with anything from a slight overestimate to a substantial underestimate.

## Predictions from single-dose readings at similar times and concentrations

A second forecast used readings directly from the single-dose trial without assuming a straight-line relationship. For each day-1 and day-3 reading, we looked for reference volunteers whose measurements were close in both concentration and time since the pill. The difference between their mean ECG responses at the two levels gave the predicted change from the recipient’s first-dose reading. At least three reference volunteers matched each reading in 35 pairs. On those visits, the reference means agreed with the day-1 late interval on average (mean error 0.0 ms; mean absolute error 6.3 ms) but underestimated the day-3 interval by 12.6 ms (mean absolute error 16.7 ms). The absolute errors count misses in either direction.

| Minimum reference volunteers near each reading | Visit pairs (recipients) | Mean rise in parent level (µg/mL) | Observed late change (ms) | Error from single-dose slope (ms) | Error from nearby readings (ms; 95% interval) |
|---|---:|---:|---:|---:|---:|
| No restriction | 60 (10) | 2.02 | +21.3 | +14.5 | — |
| At least 3 | 35 (10) | 1.88 | +18.8 | +12.4 | +12.6 (5.8 to 19.5) |
| At least 5 | 13 (5) | 1.21 | +7.4 | +3.3 | +3.2 (−10.0 to 13.8) |

Table 1. Both forecasts start from the recipient’s measured day-1 interval. Within each row they use the same visits, averaging first within recipient. A positive error means the late interval lengthened more than predicted.

Requiring five reference volunteers for each reading retained only half the recipients. Their eligible visits had smaller changes in both drug level and late recovery. Even the original single-dose slope was within 3.3 ms on average for those visits. Adding the full group’s average shortfall to every prediction would therefore be a poor correction.

## Two mornings with similar ranolazine levels

Days 2 and 3 offered a comparison that needed little concentration adjustment. Two hours after the morning pill, the only postdose hour sampled on both days, the mean concentrations were 2.247 and 2.304 µg/mL, respectively. The late interval increased by 8.1 ms relative to placebo against a predicted +0.2 ms. One large error (+32.5 ms) pulled the mean error up to +7.9 ms (2.1 to 15.0); the median was +4.5 ms. Even among the six people whose own levels stayed within a factor of 1.25, the late increase averaged 5.0 ms while concentrations fell by 0.14 µg/mL on average. Across all ten, the early interval changed by only +0.3 ms, although heart rate fell by 4.8 beats/min relative to placebo.

The shape of the T wave let us check the timing of recovery without having to mark the wave’s end. We used a representative beat from the first of the replicate recordings at this hour. Measured from the J point, the descending T wave reached 40% of its main peak height 16.2 ms later on day 3 than on day 2, after placebo adjustment. The peak itself occurred 11.4 ms later, while the descent from 80% to 40% of peak height took only 0.9 ms longer. The downstroke occurred later with little widening of its middle portion.

## Interpretation

During this high-dose course, knowing the fifth-dose blood level and the same person’s first-dose tracing still left a substantial average shortfall in the prediction of late recovery. Its size varied with the hour of measurement and was uncertain at the levels and times best represented in the single-dose trial. These results support checking a single-dose forecast against repeat-dose ECGs before using it to describe late recovery.

Meal timing was fixed in the repeat-dose trial, but the single-dose reference volunteers had fasted. A changing response to breakfast, changes in heart rate, breakdown products of ranolazine and a lag between blood concentration and cardiac response could all contribute to the shortfall. The waveform check used the same volunteers. Neither the waveforms nor the interval changes establish an effect on the risk of abnormal heart rhythms in patients.

## Methods and data sources

We used version 1.0.0 of the [CiPA clinical tables and median beats](https://physionet.org/content/ecgcipa/1.0.0/) and the [single-dose crossover clinical table](https://physionet.org/content/ecgrdvq/1.0.0/) from the public data repository [PhysioNet](https://doi.org/10.1038/s44360-026-00096-z). The initial scan covered regimens with the same active ingredients on days 1 and 3. We compared heart-rate-corrected QT, corrected J-to-T-peak, T-peak-to-end, the PR interval (conduction from atria to ventricles), QRS duration (ventricular activation) and heart rate. For each person we chose the pair closest in log concentration, requiring a day-3/day-1 ratio of 0.8–1.25. The ECG played no part in choosing the visits.

In CiPA we averaged replicate ECG changes from the day-1 predose baseline. We linked these changes to plasma levels by participant, regimen, period, day, scheduled measurement point and hour. At each point we subtracted the mean change in the parallel group of ten placebo recipients. Following the [trial protocol, p. 80](https://cdn.clinicaltrials.gov/large-docs/70/NCT03070470/Prot_000.pdf), we counted time from the active morning pill, given 1.5 hours after the trial’s nominal morning reference time. Paired day-1 and day-3 readings were at 0.5, 1, 2, 3, 3.5 and 4.5 hours after the pill. We treated concentrations below the limit of quantification as zero when calculating differences and excluded them when matching positive levels by ratio.

In the crossover trial we adjusted for heart rate by dividing QT by the cube root of the preceding beat interval (RR, in seconds) and J-to-T-peak by RR raised to 0.58. We left T-peak-to-end uncorrected and averaged replicates. We subtracted each person’s placebo reading at the same hour and their predose drug–placebo difference. For each ECG measure we fitted a common linear slope to measured postdose concentrations with a separate intercept for each person. For the forecast based on nearby readings, the times after the active pill had to be within one hour of each other. We required either a reference-to-target concentration ratio of 0.8–1.25 or an absolute difference of up to 0.05 µg/mL. We kept the closest concentration per reference volunteer. Different volunteers could supply the two reference means.

To estimate uncertainty in the slope forecasts, we resampled whole people 10,000 times independently in the ranolazine, parallel placebo and crossover groups. We recalculated the slope and the shared placebo means each time. For the forecasts from nearby readings we instead assigned each person an independent exponential weight in each resample, using that weight at every visit. This varied each reference volunteer’s contribution while retaining visits with few matches. The intervals give the central 95% of estimates for the fixed set of eligible visits. They do not adjust for selecting ranolazine and the late interval in the initial scan.

For the waveform comparison we used the first replicate median beat from each ranolazine and placebo recipient at the shared two-hour visit. We combined the electrical signal across three axes into a single measure, the vector magnitude. We smoothed it with a 9-ms moving average and located its largest peak 80–329 ms after the J point. To time the downstroke, we measured when the descending signal first crossed each fraction of peak height, taking the median signal 360–409 ms after the J point as the local floor.