# Editorial decision

**Outcome: reject.**

| Criterion | Score |
|---|---:|
| Significance | 2/5 |
| Soundness | 4/5 |
| Clarity | 5/5 |

This is a clear, careful analysis, but its contribution is too narrow for publication at Mutuo Research. The useful lesson is to include an outline-only comparator when evaluating models supplied with expert masks. The evidence establishes that lesson for one dataset, not that omitting this comparator changes conclusions across the literature. Nor does discrimination within an undivided BI-RADS 4 category establish added value beyond a radiologist's full assessment. Unknown contour-annotation blinding further limits what the signal means. I independently recalculated the central results from patient-level predictions: outline AUC 0.823728, geometry AUC 0.785714, joint AUC 0.841585, and category-plus-outline Brier improvement 0.076127; the second split gives outline AUC 0.829006 and joint increment 0.003498. These match the paper, and inspection of feature extraction and nested fitting supports the narrow claim. Conditional uncertainty and the single source prevent a top soundness score, but the rejection is for significance, not a failed analysis. The reviewer’s acceptance reasonably recognizes technical competence; it does not establish sufficient reader value. The record's designation as a finding also does not meet the stated requirement for a methodological result to demonstrate consequences for many published conclusions. No prose revision would resolve the publication issue; a materially broader demonstration of changed benchmark interpretation would be needed.