# Strong central-protein relevance does not settle the Alzheimer mechanism

**The CSF sentinel A53V remains strongly associated with measured protein after accounting for R46L and intronic rs2495477, but has little association with clinical AD.** The intronic variant retains an AD association and has weak conditional protein relevance. This pattern challenges a simple common measured-protein explanation, but the evidence is exploratory and does not identify functional PCSK9 effects, causal variants or drug safety.

This follows the [fixed LDL-set calibration audit](PROTEIN_AUDIT.md), not a new discovery of fluid-specific PCSK9 regulation. A53V and R46L were selected from Western et al.; their marginal outcomes had already been seen. We froze the two-variant comparison and a three-variant extension adding the existing intronic comparator before computing conditional results. All three AD releases and all three CSF measurements are retained separately. No assays or overlapping outcomes are pooled. [Western et al., 2026](https://pmc.ncbi.nlm.nih.gov/articles/PMC13679737/)

## What conditioning adds—and what it cannot add

For marginal per-allele effects b, reference genotype SDs D and signed LD R, we calculate joint selected-marker projections as `j = D^-1 R^-1 D b`. Marginal covariance is approximated by `V = diag(SE) R diag(SE)` and propagated through the same transformation. The reference comprises 503 European individuals. These are small-effect summary-data approximations, not individual-level conditional logistic regressions, fine-mapping, GCTA-COJO output or adjustment for every nearby variant. Small external LD panels and differences between meta-analysis samples remain important limitations. [Yang et al., 2012](https://www.nature.com/articles/ng.2213); [Deng and Pan, 2018](https://pmc.ncbi.nlm.nih.gov/articles/PMC5972416/)

An invertible joint transformation cannot change a full-vector proportionality test if all covariance terms are retained. Our marginal and joint Q values agree to numerical precision. Conditioning helps locate the effects; it is not an additional independent test.

In the three-marker model, A53V-T changes SomaScan X5231.79 by **−0.759 (SE 0.033)** and Olink by **−0.336 (0.035)** per allele. Its squared joint protein z statistics are 525 and 93; X8246.9 gives 471. These are relevance diagnostics, not multivariable-MR conditional F statistics. Its clinical AD coefficient is **−0.00457 (SE 0.01241)**. R46L has clinical AD coefficient 0.0661 (0.0335), and the intronic allele 0.0273 (0.0088).

The intronic protein coefficients are much weaker after accounting for the other markers: −0.0393 (0.0241) on X5231.79 and −0.0323 (0.0239) on Olink; squared z statistics are 2.65 and 1.82. R46L remains relevant on SomaScan (squared z 21.3 and 15.8), but Olink is imprecise (3.69). Neither weak intronic relevance nor the R46L Olink interval establishes absence of engagement.

## Common-protein mechanism test: report the failed test and its refinement

We tested the narrow model `AD = theta × measured protein lowering`, not general PCSK9 activity. The A53V/R46L pair does not reject: clinical error-free-protein P values are about 0.053, and the original conservative bound gives about 0.39. Adding the intronic marker gives ordinary Q near 13 on 2 df (P about 0.0014), but the **initially specified factor-two bound does not reject**: P=0.087, 0.086 and 0.091 across the three assays.

Inspection exposed a mathematical inefficiency: the old bound doubles AD variance even when theta=0, where protein uncertainty contributes nothing. We therefore derived a weighted bound after seeing these results. This is disclosed as a **post-result analytical refinement**, not the initially specified test or a validated new general-purpose MR method. It depends only on the covariance matrices and hypothesized theta, not on choosing a covariance that gives a desired P value.

For protein and outcome covariance Vx and Vy, weighted Cauchy implies, for every positive t and any admissible cross-study error covariance,

```
Var(yhat − theta*xhat) <= (1+t)*Vy + (1+1/t)*theta²*Vx.
```

We set `t = |theta|*sqrt(trace(Vy^-1 Vx)/n)`, which minimizes the trace of the bound after whitening by Vy. This choice is invariant to invertible joint transformations. At theta=0 the bound is Vy; at infinite theta its leading term is theta²Vx. At the true theta the quadratic form is stochastically bounded by chi-square(n). Minimizing it over theta cannot increase that tail, so **n**, not n−1, degrees of freedom gives a conservative test conditional on the covariance model. Both the original and weighted bounds include protein uncertainty and allow arbitrary cross-GWAS error covariance. Neither corrects wrong within-GWAS LD or nonnormal sampling.

The weighted clinical triple-model P bounds are **0.00646, 0.00627 and 0.0160**; the pair remains nonrejecting at 0.165, 0.162 and 0.179. New-cohort and full-release tests do not reject. Thus the intronic extension supplies the nominal disagreement, not a proven A53V-versus-R46L difference. None of the weighted results survives Bonferroni correction across all 18 assay/outcome/model comparisons (minimum adjusted P=0.113). The assays share participants, the two SomaScan measurements share a reagent, and the analytical refinement was post-result. This is evidence to qualify the simple mechanism, **not confirmatory proof of separate causal pathways**.

The [complete table](results/conditional_table.md) gives all nine assay/outcome combinations, both marker sets, and the original triple-model bound. [All fitted diagnostics](results/conditional_proportionality.csv) also retain ordinary, identity-LD and multiplicity-adjusted results.

## Precision is useful only on the measurement scale

For A53V we invert the scalar inequality `|y − theta*x| <= 1.96*(sy + |theta|*sx)`, a worst-covariance confidence set that includes protein uncertainty. In the three-marker clinical model, the X5231.79 scaled association is **−0.0060 (−0.0416 to 0.0284)** AD log odds per SD lower standardized log10 protein. Olink gives **−0.0136 (−0.1080 to 0.0739)** per lower released unit. These are descriptive, instrument-scaled associations under the chosen marker projection, not identified causal effects. The Olink scale cannot be equated to a SomaScan SD.

At two-sided alpha 0.05, an 80%-power calculation based on the conditional AD SE and treating the observed A53V protein coefficient as truth gives a detectable log-OR magnitude of 0.0458 for X5231.79 and 0.1035 for Olink. Substituting the lower 95% protein-effect magnitude gives 0.0501 and 0.1300. These are plug-in design calculations, not observed power, proof of equivalence or dose conversions. Protein selection, binding effects, participant selection and possible winner's curse prevent turning the narrow interval into a drug-safety statement.

## Reference-LD and numerical checks

One thousand resamples of the reference participants preserve the small A53V AD point estimate and strong protein association. They reveal substantial instability in the weak intronic protein projection: its X5231.79 coefficient ranges from −0.0875 to 0.0130 between bootstrap percentiles 2.5 and 97.5. These are **LD-only sensitivity ranges**, not GWAS confidence intervals. The clinical triple weighted P ranges are 0.00351–0.01067 for X5231.79 and 0.00922–0.02463 for Olink at the same percentiles; identity-LD values are 0.00861 and 0.02153. Reference sampling does not remove the nominal pattern, but bootstrapping cannot address population mismatch.

Run `bash studies/mr/williams2020-pcsk9-alzheimer/analysis/run_conditional.sh`, then `pixi run python studies/mr/williams2020-pcsk9-alzheimer/analysis/verify_conditional.py --replay`. The branch reuses raw data fetched by the regional, protein and orthogonal scripts and is integrated into `run_update.sh`.

Independent verification aligns all 18 associations from raw sources, reconstructs genotype normal equations for 30 joint coefficients and covariances, independently optimizes all 36 bound diagnostics, checks 1,080 admissible-covariance examples of the weighted PSD inequality, and checks all 18 ratio confidence sets and nine table rows. An isolated existing-input replay reproduces nine outputs byte-for-byte. This is not another network refetch or an independent biological replication. Exact errors, hashes and scope are in [the validation report](results/conditional_validation.json).

## What to do next

The useful outcome is a boundary on interpretation: a well-measured central-protein signal cannot simply be substituted for the LDL instruments, and the conditional pattern does not establish that central protein mediates their AD association. More unmatched marginal GWAS will not fix this. The [main paper](PAPER.md) now synthesizes dataset dependence and target calibration, keeping this exploratory mechanism test subordinate. A genuinely matched recruitment/age comparison or a functional, non-affinity measurement could discriminate mechanisms; neither is required to state the bounded findings already established.
