# LDL instruments do not encode one dose of measured CSF PCSK9

The fixed five-variant LDL instrument set predicts lower measured CSF PCSK9, but its variants do not have a common LDL-to-protein effect ratio. This mismatch now appears on both SomaScan and the orthogonal Olink platform, although the samples are not independent and both platforms use affinity binding. This is a target-calibration result, not an explanation of the clinical-versus-broader Alzheimer association and not a drug-safety result.

![LDL and CSF protein reductions for the fixed variants and the literature-selected A53V comparator.](results/protein_figure.png)

## What is new, and what is not

Fluid-specific PCSK9 regulation is already reported by Western et al. (2026), including primary CSF A53V and plasma R46L signals, a secondary shared signal, and Olink support. We do not claim that discovery. Our extension asks whether the **exact LDL instruments used in this study** can be interpreted as a common measured central-protein perturbation. [Western et al., 2026](https://doi.org/10.1126/scitranslmed.adz2016)

We retrieved both publicly indexed PCSK9 CSF analytes from the 2024 study: X5231.79 (GCST90426288) and X8246.9 (GCST90427290). Protein values were log10-transformed and standardized within cohort groupings. The analyzed rows have N=3,472 and N=3,291, respectively. Both analytes map to **SomaID SL012707** and share participants; their agreement is not independent replication or orthogonal assay validation. The final-paper supplement reproduces the X5231.79 A53V coefficient in the indexed statistics. [Western et al., 2024](https://doi.org/10.1038/s41588-024-01972-8)

The plan retained all seven existing LDL variants without replacement. Six are available in each analyte; E670G/rs505151 is missing. Therefore the historical three-SNP and coding-pair fits cannot be run on their original membership. The fresh five-SNP set is complete. A53V/rs11583680 is a separate, literature-selected comparator; its AD data had already been seen during file inventory, so this extension is explicitly exploratory rather than outcome-blind.

## Results

All six available fixed variants have same-direction LDL and CSF protein effects. Relevance is therefore not absent: for example, R46L-T lowers X5231.79 by 0.444 SD (95% CI 0.245–0.643) and LDL-C by 0.432 SD per allele. However, rs45576433-G lowers the same protein measurement by 0.418 SD (0.351–0.484), despite lowering LDL-C by only 0.0188 SD. A53V-T lowers the protein measurement by 0.761 SD (0.696–0.826), against 0.0237 SD lower LDL-C. Similar directions but different magnitudes are the key observation; this is not a sign-discordance claim.

For the fresh five, the common proportionality model gives Q=148.64 on 4 df (P=3.98×10⁻³¹) for X5231.79 and Q=138.08 (P=7.27×10⁻²⁹) for X8246.9. Identity-LD sensitivities give the same conclusion. The corresponding pooled slopes, −1.514 and −1.367 protein SD per SD lower LDL-C, are poor summaries of a common perturbation and should not be promoted as calibrated central-target doses.

The mismatch does not require treating LDL effects as error-free. A deliberately conservative diagnostic includes both sets of marginal SEs and permits arbitrary cross-GWAS estimation-error covariance. Its minimized quadratic forms are 73.30 and 68.31, compared with chi-square distributions on **5**, not 4, df; conservative P bounds are 2.10×10⁻¹⁴ and 2.31×10⁻¹³. These remain conditional on approximate normal sampling and the supplied European LD matrix.

Leaving out rs45576433 reduces ordinary Q to 14.92 and 11.43 (3 df), but conservative P bounds rise to 0.116 and 0.224. Leaving out any other fresh-set SNP retains strong rejection under the conservative diagnostic. Thus one variant supplies much of the decisive evidence under the least favorable assumptions. It has r²=0.232 with A53V in the reference panel; the observations are not independent central signals or a fine-mapping result. A53V and R46L themselves have r²=0.000175.

A53V-T is nearly null in clinical-consensus AD: per-allele OR 0.998 (0.974–1.022), compared with 1.024 (0.994–1.054) in new European cohorts and 1.010 (0.992–1.028) in the full European release. These intervals concern the allele, not a therapeutic effect or an identified causal protein effect. This pattern motivates a direct central-protein mechanism test, but does not establish one: protein binding, processing, localization and activity can differ from measured abundance.

All effect-allele estimates, including explicit missing rows, are in the [generated table](results/protein_table.md).

## Orthogonal CSF follow-up: the mismatch is not confined to one SomaScan reagent

A publication-specific GWAS Catalog query identified **GCST90944847**, the public CSF Olink release from Western 2026. The earlier generic PCSK9 ontology query missed its CSF-specific term (OBA_2059888). Its selected rows have N=2,489, rather than the study-wide 2,524. All six previously available LDL variants and A53V are present; E670G remains absent. The same fixed five-SNP set is complete. No variant was replaced. [Catalog metadata](https://www.ebi.ac.uk/gwas/rest/api/v2/studies/GCST90944847), [indexed release](https://ftp.ebi.ac.uk/pub/databases/gwas/summary_statistics/GCST90944001-GCST90945000/GCST90944847/harmonised/)

The prespecified orthogonal test supports nonproportionality: **Q=33.27 on 4 df, P=1.05×10⁻⁶**. The conservative diagnostic, allowing LDL uncertainty and arbitrary cross-GWAS error covariance, gives Q=16.59 on 5 df and P=0.00535. Identity-LD Q=33.72 gives the same conclusion. Omitting rs45576433 removes the mismatch (ordinary Q=2.18 on 3 df, P=0.536; conservative P=0.896). Omitting any other fresh-set variant leaves conservative P between 0.0024 and 0.0073. This is one fixed-set follow-up with descriptive deletion checks, not multiple independent confirmations.

On Olink, rs45576433-G changes measured CSF PCSK9 by −0.204 (95% CI −0.271 to −0.137) released protein units per allele despite only −0.0188 SD LDL-C. A53V-T gives −0.338 (−0.406 to −0.270), with −0.0237 SD LDL-C. R46L-T gives −0.178 (−0.373 to 0.016), with −0.4324 SD LDL-C. Its imprecise Olink association is not evidence of absent central engagement. All six LDL/protein effect directions agree, as in SomaScan. Complete paired-platform coefficients, including the missing variant, appear in [the generated table](results/orthogonal_table.md).

We preserve Olink coefficients in their released units. The metadata do not independently specify the normalization scale, and the main paper's pooled normalization description does not establish an exact numerical conversion between platforms. The dimensionless proportionality tests are unchanged by a common rescaling of protein beta and SE. We therefore do not interpret smaller Olink coefficients as weaker biological effects, or compare their raw magnitudes formally with SomaScan. Olink adjusts for protein PC1–2 in addition to age, sex, genetic PCs, cohort and genotyping array; the SomaScan metadata do not list protein PCs.

This closes the narrow **single-SomaID** objection to the calibration failure. It does not establish true abundance or function: both assays use affinity binding, participant overlap is unquantified, and the rs45576433 signal tags the coding A53V signal. Cross-platform agreement cannot exclude shared binding effects. Failure of this narrow abundance-proportionality model does not by itself invalidate every LDL-based MR analysis: measured protein concentration need not equal the relevant target activity. Western already reported Olink support for the CSF sentinel; our extension is the fixed LDL-set calibration and its leave-one-out dependence, not discovery of that sentinel or fluid specificity.

## Plasma and assay audit

An older ONTIME European plasma release provides rounded SomaScan coefficients for the same six fixed variants and A53V. R46L has P=1.2×10⁻¹³ and 4.4×10⁻¹³ in its two analytes, while A53V has P=0.91 and 0.53 and rs45576433 P=0.43 and 0.30. We retain every extracted row in `protein_plasma_context.csv`, but do not compare raw plasma and CSF coefficient magnitudes, assume matching standardization, or interpret significance in one fluid and not the other as a difference test. This release supplies contextual direction and precision, not a new cross-fluid causal analysis. [ONTIME plasma X5231.79](https://ontime.wustl.edu/pheno/PCSK9_Plasma_NHW_1), [X8246.9](https://ontime.wustl.edu/pheno/PCSK9_Plasma_NHW_2)

As an orthogonal plasma check, the published Olink conditional-signal table identifies R46L-T as a PCSK9-lowering signal with PIP=1 and a one-variant credible set. We extracted all 17 PCSK9 signal rows, not just R46L. Conditional coefficients are kept on their reported scale and never substituted for marginal GWAS effects. Absence of A53V from this signal list is not a quantitative null test. This plasma result alone does not validate CSF A53V measurement: the two CSF analytes share a SomaID, and a coding allele can alter binding in more than one affinity assay. [Sun et al., 2023, Supplementary Table 16](https://doi.org/10.1038/s41586-023-06592-6)

## Conservative proportionality diagnostic

For LDL effects x, protein effects y and signed LD R, set Vx=diag(sx) R diag(sx) and Vy=diag(sy) R diag(sy). Under y=true theta×x, the estimated residual has unknown cross-study covariance, but

    Var(yhat − theta*xhat) <= 2*(Vy + theta²*Vx)

in positive-semidefinite order. This follows by applying Var(U−V) <= 2 Var(U)+2 Var(V) to every linear combination. At the true theta, the quadratic form using this upper covariance bound has a tail bounded by chi-square(n). Taking its minimum over theta cannot increase that tail probability. We use n degrees of freedom to retain this conservative argument, rather than subtracting one for a fitted slope. The numerical search uses theta=tan(phi), includes both infinite-theta limits, and searches every local minimum on a dense angle grid. An independent differential-evolution implementation checks the minima.

This is a sensitivity bound, not an overlap estimate or a replacement for a well-characterized joint likelihood. A narrow equality-of-effects model can fail because of biology, assay behavior or both. The diagnostic does not identify which.

## Reproduction and next experiment

Run `bash studies/mr/williams2020-pcsk9-alzheimer/analysis/run_protein.sh --fetch`, then `pixi run python studies/mr/williams2020-pcsk9-alzheimer/analysis/verify_protein.py --network`. Source URLs, commands and hashes are in `results/protein_fetch.json`; raw files remain under `data/protein/`. The branch reuses prior exposure selection, coordinate anchors, regional LD and AD/CAD harmonization. It is not a whole-study clean replay.

Independent checks rebuilt 30 GLS models and 14 conservative diagnostics from raw inputs; all 14 numeric table cells passed. An isolated network refetch of all protein-branch inputs reproduced 11 scientific/table/figure outputs byte-for-byte (`results/protein_validation.json`). The full existing-input `run_update.sh` pipeline also completed with the new branch.

The orthogonal follow-up now runs with `analysis/run_orthogonal.sh --fetch` and `analysis/verify_orthogonal.py --network`. Source hashes, all allele alignments, missing-set audits and all 15 models are in `results/orthogonal_*`.

Independent checks reconstructed all seven Olink associations, 15 GLS models and seven conservative diagnostics (maximum numerical errors 1.42×10⁻¹⁴ and 7.50×10⁻¹³). All seven numeric Olink table cells and the missing cell passed. An isolated network refetch of all orthogonal-branch inputs reproduced seven outputs byte-for-byte (`results/orthogonal_validation.json`); prior exposure/LD, coordinate anchors and the SomaScan table were reused.

The [conditional protein/AD comparison](CONDITIONAL_AUDIT.md) is now complete. A53V remains strongly protein-associated but nearly null for clinical AD after accounting for R46L and the intronic comparator. The two-signal pair does not reject proportionality. Adding the intronic signal gives nominal disagreement under a sharper, post-result conservative covariance bound, but not under the original factor-two bound or correction across all 18 comparisons. This is an exploratory challenge to a simple measured-protein mechanism, not causal sharing or a safety result. The full report includes protein uncertainty, reference-LD resampling, precise measurement-scale limits and both bounds. The [main paper](PAPER.md) now distinguishes this target-calibration failure from the still-unexplained AD dataset discrepancy; the [supplement](SUPPLEMENT.md) retains the other follow-ups.
