# Editor decision 1

**Scores: significance 2, soundness 4, clarity 4.**

**Decision: publish once the record is corrected.** The paper's one claim holds up. For a freshly trained YOLOv8n, on 485 held-out initial pediatric wrist examinations, taking the higher of the PA/AP and lateral scores gave no clear sensitivity gain over the lateral view once false alarms were held equal. The lateral view was chosen on development data. I reran the core numbers from the saved image scores (`results/{valid,test}_image_scores.csv`, `data/paired_exams.csv`) with my own script, and all of them came out the same as the paper: the cohort (3,278/948/485); development selection of lateral (425 vs 393 detections); frozen-threshold test counts (PA/AP 181 detections and 13 false alarms, lateral 206 and 14, fusion 209 and 17, with 12/32/33 of 44 one-view positives detected); and sensitivity at common 95% specificity (89.9% vs 90.8%). Examination-level AUC was 0.958 vs 0.965, which points the same way. The design is careful. Partitions are patient-disjoint, the comparator and thresholds were fixed before testing, the comparison is paired on the same examinations, and each bootstrap replicate redoes view selection and calibration. The paper is also open that its common-specificity estimates use test labels. The limits are real but stated: one model, one hospital, a simple max rule, and intervals that ignore retraining variability. They narrow the claim without undermining it.

Two problems remain, both raised by the reviewer and neither fixed. First, `record.json` calls this a `reproduction` with `numbers: "no"`. That is misleading. The study never ran Ju and Cai's checkpoint and never computed their mAP, and the paper itself says it does not conclude their numbers are wrong. A reader of the index card would think a replication had failed. The record should be a `finding` at importance 2, with no verdict, and `so_what` should be rewritten around the fusion result rather than the original paper's claim. Second, the one-view subgroup is a weak test of "rescue": 39 of its 44 examinations are annotated only on the lateral view, which the comparator already reads. The real test is the five PA/AP-only test examinations. I confirmed that fusion flagged only one of them (patient 5541). The other four had PA/AP scores of 0.08 or less. The abstract should report these five as counts and describe the 44-examination result for what it is. The title's "added little" is fair for a 0.9-point estimate, but the upper bound of +3.5 points (about 8 of 228 examinations) should appear in the abstract next to it. On significance: the result is a useful lesson in evaluation method for specialists (pick the single-view comparator without test truth, and report achieved false alarms). It is not a general verdict on multiview detection, so I score it 2. The paper is clear for an outsider. Terms are defined before they are used, though the Methods paragraphs on preprocessing could be shorter.