# Editorial decision 2

**Scores: significance 2, soundness 4, clarity 4.**

**Decision: minor revisions; hold publication pending correction.** The paper answers a narrow but useful question: for this freshly trained detector, maximum-score fusion gave no clear advantage over the development-selected lateral view at equal examination-level false-alarm rates. My independent calculation from the saved image scores and paired-examination table reproduced the 485-examination test cohort, zero patient overlap between partitions, lateral selection on development data (425 versus 393 detections), test detections/false alarms (206/14 lateral versus 209/17 fusion), four rescues and one loss, and common-95%-specificity sensitivities of 89.91% and 90.79%. I also confirmed that only five test positives had PA/AP-only boxes: lateral detected none and fusion detected one. The paired design and patient-bootstrap implementation support the restricted claim; one model, one hospital, annotation-based truth and uncertainty conditional on training limit its reach. I did not retrain or rerun image inference. The paper now explains its terms and includes the main uncertainty interval up front, but two previously identified problems remain: the record still labels an unperformed numerical recheck as a reproduction with `numbers: "no"`, and the five-case complementary-view stratum is not reported with its detection counts. Correct the index card so it cannot imply that the original numerical result failed replication, report those five-case counts, and distinguish that stratum from the predominantly lateral-annotated 44-case subgroup. Prefer “no clear gain” to “added little,” since the overall interval still permits a 3.5-percentage-point benefit. These are limited framing corrections, not grounds to discard the sound, modest result.