ReproductionMR

A larger stroke genetics study gives less precise evidence about iron and stroke

Version 1 Published 2026-10-29 DOI 10.5281/zenodo.24373612

You are reading version 1. Read the latest version (3).

Original paper Iron Status and Risk of Stroke Gill et al. (2018). Stroke. doi:10.1161/STROKEAHA.118.022701
Numbers reproduced
Yes
Original conclusion
Unclear

The original cardioembolic estimate reproduces, but the later near-null estimate is less precise at all three instruments and does not resolve the causal iron–stroke conclusion.

In plain English

The larger stroke genetics study gave less precise answers at all three genetic markers used to test whether iron levels affect stroke risk, and left them out entirely for one type of stroke. That means its apparently reassuring result is not a stronger test simply because the study is bigger—a reason to look beyond participant counts when judging health headlines. This analysis does not tell us whether taking iron supplements changes stroke risk.

Research manuscript for human review · 29 October 2026

The larger GIGASTROKE genetic study measures stroke associations less precisely at all three variants used in the original iron–stroke analysis. Its small-vessel stroke results omit all three. The original estimate linking higher iron to stroke caused by a clot from the heart reproduces, but the later estimate near zero has a wider confidence interval. This matters because genetic studies use these variants as natural experiments for iron levels. A larger study can weaken that experiment if the chosen variants lose precision or disappear from its results.

Background

Mendelian randomization (MR) uses genetic associations with an exposure and an outcome to estimate a causal effect, assuming the variants affect the outcome through that exposure. Gill et al. used HFE C282Y (rs1800562), HFE H63D (rs1799945) and TMPRSS6 rs855791. Their effects agree across four biomarkers of systemic iron status. The headline outcome was any stroke; ischemic stroke and its subtypes were separate analyses. We rechecked the cardioembolic result, which concerns clots originating in the heart, using the original transancestry MEGASTROKE results before comparing European releases. Gill et al., 2018

Later work supported the cardioembolic association with larger iron studies and European MEGASTROKE outcomes, and examined iron effects by genetic region. Our comparison with GIGASTROKE instead led to an audit of precision and variant availability. Barad et al., 2024; Allara et al., 2024

Results

Precision at the original variants

Using the published, rounded iron coefficients and the original three variants, we obtain an odds ratio (OR) of 1.158 per standard-deviation increase in serum iron for transancestry MEGASTROKE cardioembolic stroke. Its 95% confidence interval (CI) is 1.014–1.322, closely matching the published 1.16 (1.01–1.32). The European reconstruction is also positive. European GIGASTROKE gives an estimate near zero on the log-odds scale, with wider intervals (Table 1).

Table 1. Serum-iron estimates using the same exposure coefficients and exact instruments. “Random” denotes multiplicative random-effects intervals, which allow for disagreement among variant estimates. Q measures this disagreement and has two degrees of freedom. SE is standard error.

Cardioembolic outcome OR Fixed 95% CI Random 95% CI Fixed log-OR SE Q (2 df)
MEGASTROKE, transancestry 1.158 1.014–1.322 1.001–1.338 0.0678 2.38
MEGASTROKE, European 1.188 1.033–1.366 1.033–1.366 0.0714 1.51
GIGASTROKE, European 0.999 0.836–1.194 0.680–1.468 0.0911 9.28

Generated table; all fitted results.

The loss of precision is visible in the stroke associations before scaling them by iron effects. Outcome standard errors at C282Y, H63D and TMPRSS6 rise from 0.0416, 0.0277 and 0.0194 in European MEGASTROKE to 0.0507, 0.0334 and 0.0266 in European GIGASTROKE. The MR log-OR standard error rises from 0.0714 to 0.0911. The comparison within European results rules out the change from transancestry to European data as the explanation. Precision audit

GIGASTROKE's European cardioembolic sample has 10,804 cases. Its source table assigns 6,189 to unchanged MEGASTROKE cohorts, 718 to updated cohorts and 3,897 to new cohorts. These labels describe cohorts rather than individual overlap. We therefore compare the releases without pooling them or testing their difference as independent estimates. Source-table extraction; Mishra et al., 2022

Nearby HFE variants

Nearby variants provide a check on whether the precision loss follows the iron association. The markers rs79220007 and rs198851 track C282Y and H63D, respectively, with observed dosage correlation r²=1 in 503 European 1000 Genomes participants. Their allele phase was checked. In GIGASTROKE cardioembolic results, these linked markers, or tags, have 2.318 and 2.284 times the inverse-variance information of the original variants. Reference correlations and tag selection

The tags also have nearly identical measured iron effects. In FinnGen's Kanta laboratory study, the phase-aligned tag/original coefficient ratios are 0.998866 and 0.996455. Thus stronger iron associations at the tags do not explain their better stroke precision. Kanta measures inverse-normalized, within-person median clinical laboratory iron in 56,958 participants, a different scale from the original population iron assays. Exposure calibration; Kanta documentation

With Kanta coefficients throughout, the exact-three cardioembolic OR is 1.013 (fixed 95% CI 0.773–1.328). Replacing only the two HFE variants gives 1.209 (0.993–1.472). Random-effects intervals are wide at 0.565–1.814 and 0.751–1.946. These fits show how marker choice affects the estimate; the tags were selected after inspecting precision. The TMPRSS6 comparison marker rs4820268 has r²≈0.76 with rs855791 and is too weakly correlated to serve as an interchangeable proxy. Measured-exposure fits

Availability across stroke subtypes

To compare precision across variants with different allele frequencies, we calculate an information diagnostic, I=1/[2f(1-f)SE^2], where f is allele frequency and SE is the stroke log-OR standard error. We divide it by the median among common variants in the same 500 kb region. Higher values mean greater frequency-adjusted precision; the diagnostic is not a measured sample size.

The original instruments have about 60–66% of local median information for any stroke, 57–63% for ischemic stroke and 38–43% for cardioembolic stroke. The nearby comparison markers remain close to their local medians (Figure 1).

Information and availability at the same six variants across stroke outcomes

Figure 1. Relative information and availability in European GIGASTROKE. Cells show information divided by the common-variant median in the same 500 kb region. Dashed cells indicate absence. The outcomes overlap, and the TMPRSS6 comparison is only partially correlated with its original variant. Generated numerical table

Large-artery stroke retains only H63D from the original panel; small-vessel stroke retains none. Full scans of 5,784,788 original large-artery and 5,974,028 original small-vessel rows confirm these five absences before GWAS Catalog harmonization. An analysis using whichever original variants remain would change its instruments across subtypes. Original-file missingness audit

Genome-wide precision and availability

We extended the audit to common variants present in the original European cardioembolic file, defining common as minor-allele frequency (MAF) ≥0.05. Here we normalized information by chromosome medians. Excluding chromosomes 6 and 22, which contain the iron instruments, leaves 5,004,338 variants. Of these, 58,429 have information below half their chromosome median. Small-vessel results lack 88.05% of this low-information group, compared with 0.65% of other common variants (Table 2).

Table 2. Subtype availability outside chromosomes 6 and 22, grouped by cardioembolic information. Variants are correlated and outcomes overlap, so the counts are descriptive rather than independent observations for significance testing.

Cardioembolic information Variants Absent: large artery Absent: small vessel
Below half chromosome median 58,429 28,146 (48.17%) 51,449 (88.05%)
Other common variants 4,945,909 49,491 (1.00%) 32,257 (0.65%)

Generated table; source counts.

The pattern persists at high allele frequency. Among variants with MAF 0.30–0.50, small-vessel results lack 14,983/17,032 (88.0%) low-information variants and 191/1,647,717 (0.0116%) other variants. Across four frequency strata, the low-information group has median normalized cardioembolic information near 0.42. Frequency-stratified counts

We examined two possible technical explanations. The original iron variants appear on a HumanExome genotyping-array manifest, but most common markers on that manifest have normal information. Outside the iron chromosomes, their median normalized information is 0.996. Low information occurs in 1,702/22,551 (7.55%) manifest markers and 56,727/4,981,787 (1.14%) other variants. Array membership identifies a higher proportion with low information, while most affected variants fall outside the manifest. Array-content audit

The iron variants also have multiple manufacturer names. Among numeric-exm markers outside the iron chromosomes, however, low information occurs in 1,375/15,661 (8.78%) with multiple names and 97/830 (11.69%) with one name. Multiple names do not account for the general deficit (Figure 2). Alias audit

Genome-wide subtype dropout by allele frequency and the manufacturer-name comparison

Figure 2. Variant absence and manufacturer names. Both panels exclude chromosomes 6 and 22. Left: small-vessel absence by cardioembolic information group and MAF. Right: low-information fractions among numeric-exm markers grouped by number of manufacturer names.

Earlier SiGN results

We asked whether the same low-information variants were already poorly measured in an earlier stroke dataset. Before extracting their results from public European SiGN files, we fixed 40 low/normal-information pairs matched on chromosome, HumanExome membership, allele frequency and position. All have later cardioembolic MAF ≥0.30. Selection rule; SiGN dataset

Both earlier outcomes contain 38/40 low-information markers and all 40 normal comparators. Of the low markers, 36 participate in every reported analysis stratum; all 40 comparators do. On the same 38 complete pairs, median low/normal information is 1.000 in each earlier outcome and 0.416 in later cardioembolic results (Table 3). Later small-vessel results omit 39/40 low markers and retain all 40 comparators.

Table 3. Historical coverage and information in the fixed panel. Groups are defined from GIGASTROKE cardioembolic information. Presence and participation use all 40 pairs; both information medians use the identical 38 complete pairs. CES denotes cardioembolic stroke. Ratios compare information within pairs.

Earlier outcome Low present Normal present All strata: low; normal SiGN median ratio (38 pairs) GIGASTROKE CES ratio (same 38)
SiGN cardioembolic 38/40 40/40 36/40; 40/40 1.000 0.416
SiGN small artery 38/40 40/40 36/40; 40/40 1.000 0.416

Generated table; unrounded calculations.

All six iron variants are present in SiGN and contribute across all 10 reported cardioembolic and 9 small-artery strata. HFE tag/original inverse-variance ratios are 0.997 and 1.000 for cardioembolism and 1.000 for both small-artery pairs. The later precision disparity and variant loss therefore vary by dataset. Iron-pair comparison

Information in the fixed matched panel across later and earlier stroke releases

Figure 3. Information ratios in earlier SiGN and later GIGASTROKE. Each point is a matched pair. Selection imposed the x-axis contrast; the y-axis was unused in selection. Dashed horizontal lines indicate equal information within a pair; dotted diagonals indicate equal ratios across releases. Each panel shows 38 complete pairs. Two low markers are absent and two others have incomplete stratum participation. All remain in the coverage denominators.

Interpretation and limits

At these iron instruments, the larger stroke release supplies a less precise test and incomplete subtype coverage. The earlier public SiGN results show that most selected low-information variants once had precision comparable to matched markers. Exact variant availability and outcome standard errors should therefore accompany MR updates and subtype comparisons. Nearby tags can help diagnose a precision problem when their exposure effects are measured and their selection rule is explicit.

The cause of the deficit remains unresolved. Public SiGN differs from the non-overlapping subset submitted to GIGASTROKE, and the public meta-analysis files lack per-variant participation and exclusion reasons. The selected high-frequency panel cannot estimate genome-wide historical prevalence, and our genome-wide audit covers only variants present in cardioembolic results. Manufacturer annotations do not establish actual cohort genotyping or submitted names. Participation, imputation, estimation and quality-control filtering remain possible explanations. The causal iron effect also remains uncertain: the releases share cohorts, the tags were precision-selected, reference correlations may vary across cohorts, and iron-regulatory variants may affect stroke through other pathways. These estimates do not establish the effect of an iron intervention.

The next useful evidence is the exact submitted cohort inputs and pre- and post-quality-control participation records for the fixed panel. Those records could locate where precision and availability changed.

Methods and reproducibility

Analysis sequence and MR estimation

This was a sequential exploratory investigation. Reconstruction preceded regional precision checks, linked-marker selection, measured-exposure calibration, subtype availability, genome-wide annotations and the historical panel. The array-content test was recorded before genome-wide matching; marker-name multiplicity was a subsequent hypothesis. The historical panel was fixed before its SiGN rows were extracted. Related atrial-fibrillation and control-selection work remains in Exploratory analyses.

We extract Genetics of Iron Status (GIS) exposure coefficients from Gill's supplement, preserve allele frequencies and align outcome alleles explicitly. H63D's palindromic C/G alleles are resolved by frequency. The primary reconstruction uses the three exact variants. For iron coefficients b_X, stroke log-ORs b_Y and their standard errors SE_Y, the inverse-variance-weighted estimate is

\hat\theta=\frac{\sum b_Xb_Y/SE_Y^2}{\sum b_X^2/SE_Y^2},\qquad SE(\hat\theta)=\left(\sum b_X^2/SE_Y^2\right)^{-1/2}.

Random-effects standard errors multiply this by \sqrt{\max(1,Q/(k-1))}, where k is the number of variants and Q measures heterogeneity. Intervals use ±1.96 SE on the log scale. Delta-weighted sensitivity includes exposure uncertainty in ratio variances. The published exposure coefficients are rounded. The two HFE variants have reference correlation r=0.074; the primary diagonal-weight fit follows the original reconstruction. The three variants represent two genetic regions, and the correlated iron biomarkers supply related estimates.

Data and information measures

MEGASTROKE cardioembolic accessions are GCST005842 (transancestry) and GCST006910 (European). European GIGASTROKE accessions GCST90104539–GCST90104543 cover any, ischemic, cardioembolic, large-artery and small-vessel stroke. We use univariate releases. Regional queries use harmonized GRCh38 coordinates and verified alleles; original-file availability and genome-wide matching use GRCh37 coordinates plus allele sets. GIGASTROKE used ancestry-specific fixed-effect meta-analysis with cohort- and meta-analysis-level quality control, including participation and heterogeneity filters. GIGASTROKE methods

Information medians use common variants in two fixed 500 kb windows for regional comparisons and on the same chromosome for genome-wide comparisons. The genome-wide universe contains 5,422,856 cardioembolic variants before excluding chromosomes 6 and 22. HumanExome v1.2 content is matched by GRCh37 coordinate and forward-strand allele set, collapsing duplicate probes. Omni5Exome v1.0 auxiliary assignments supply marker-name multiplicity. HumanExome manifest; manufacturer files

The historical panel has one pair on each of the 20 non-iron autosomes within each HumanExome-membership category. Both markers have MAF ≥0.30, differ by ≤0.02 in MAF and lie ≤1 Mb apart. Low information is <0.5 chromosome median; normal is 0.9–1.1. Hash ordering selects eligible low markers and distance selects comparators, without using SiGN results. We extract European TOAST cardioembolism and small-artery occlusion. Stratum participation comes from direction strings, checked against heterogeneity degrees of freedom plus one. Reported SiGN N_EFF is retained separately from our diagnostic. SiGN publication and supplement

All three complete original subtype files pass deposited MD5 checks. Independent weighted regression checks MR arithmetic, independent raw-row parsing checks information calculations, and full-file AWK scans verify all 86 requested SiGN positions per outcome, including absences.

References and acknowledgments

  1. Gill D et al. Iron Status and Risk of Stroke. Stroke (2018). doi:10.1161/STROKEAHA.118.022701.
  2. Benyamin B et al. Novel loci affecting iron homeostasis and their effects in individuals at risk for hemochromatosis. Nature Communications (2014). doi:10.1038/ncomms5926.
  3. Malik R et al. Multiancestry genome-wide association study of 520,000 subjects identifies 32 loci associated with stroke and stroke subtypes. Nature Genetics (2018). doi:10.1038/s41588-018-0058-3.
  4. Mishra A et al. Stroke genetics informs drug discovery and risk prediction across ancestries. Nature (2022). doi:10.1038/s41586-022-05165-3.
  5. Barad A et al. Associations Between Genetically Predicted Iron Status and Cardiovascular Disease Risk: A Mendelian Randomization Study. Journal of the American Heart Association (2024). doi:10.1161/JAHA.124.034991.
  6. Allara E et al. Novel loci and biomedical consequences of iron homoeostasis variation. Communications Biology (2024). doi:10.1038/s42003-024-07115-3.
  7. NINDS Stroke Genetics Network and International Stroke Genetics Consortium. Loci associated with ischaemic stroke and its subtypes (SiGN): a genome-wide association study. Lancet Neurology (2016). doi:10.1016/S1474-4422(15)00338-5.

We thank the participants and investigators of the source studies. The MEGASTROKE project received funding from sources specified at its acknowledgments page; its requested consortium author-list supplement preserves source names and affiliations. These are source-study contributors, not authors of this reanalysis. We acknowledge GIGASTROKE, FinnGen and its public laboratory-GWAS resource, and SiGN/ISGC through the Cerebrovascular Disease Knowledge Portal. The exploratory appendix includes acknowledgments for its AF datasets.