ReproductionMR

A larger stroke genetics study gives less precise evidence about iron and stroke

Version 3 Published 2026-11-01 DOI 10.5281/zenodo.24373624 First published 2026-10-29

Original paper Iron Status and Risk of Stroke Gill et al. (2018). Stroke. doi:10.1161/STROKEAHA.118.022701
Numbers reproduced
Yes
Original conclusion
Unclear

The original serum-iron cardioembolic estimate reproduces; no original error was identified, and the less precise, overlapping later data leave the causal conclusion unresolved.

In plain English

The original study linked genetically higher iron levels to stroke caused by clots from the heart. We reproduced that estimate and checked it against a larger stroke genetics study. The larger study gave a result near zero, but measured all three genetic markers less precisely and omitted them for one stroke subtype. It therefore does not settle whether iron raises stroke risk or show that the original result was wrong. These genetic estimates do not tell us whether taking iron supplements changes stroke risk.

Does higher iron in the body increase stroke risk? Genetic studies can help answer this question, but a larger sample does not guarantee a clearer answer. We reproduced an earlier association between higher iron and cardioembolic stroke, caused by clots originating in the heart. Yet GIGASTROKE, a larger study of genetic associations with stroke, measured stroke associations less precisely at all three iron-related variants used in that analysis. The combined estimate's standard error, a measure of uncertainty, rose from 0.0714 to 0.0911 when comparing European participants across the two studies. GIGASTROKE's results for stroke involving small blood vessels omit all three variants. Comparisons across the genome and with an earlier dataset show that this loss of precision and coverage extends beyond the iron markers. Study size alone therefore gives a misleading guide to the strength of this updated test.

Background

Gill et al. reported in 2018 that genetically predicted higher iron status increased stroke risk, with the strongest evidence for cardioembolic stroke. Their headline outcome was any stroke; ischemic stroke, caused by blocked blood flow, and its subtypes were separate analyses. The study offered evidence about causation that ordinary comparisons of people with different iron levels could not readily provide. Later analyses using larger iron studies also supported the cardioembolic association, making it important to understand what a newer stroke dataset adds. Gill et al., 2018; Barad et al., 2024

The method, Mendelian randomization (MR), uses genetic variants associated with an exposure, here iron levels, as natural experiments. A variant's association with stroke is divided by its association with iron to estimate the effect of higher iron levels. This interpretation assumes that the variant affects stroke through iron rather than through another pathway. Gill and colleagues chose three variants whose effects agreed across four iron biomarkers: serum iron (iron in the liquid portion of blood), ferritin (a marker of iron stores), transferrin (the iron transport protein) and transferrin saturation (the fraction of that protein carrying iron). Two variants, C282Y (rs1800562) and H63D (rs1799945), lie in HFE; the third, rs855791, lies in TMPRSS6. Both genes help regulate iron levels. The rs identifiers uniquely label genetic variants. These three variants are the study's genetic instruments.

We reconstructed the cardioembolic estimate using MEGASTROKE, the study of genetic associations with stroke used by Gill and colleagues. Their main analysis combined participants from multiple ancestry groups, termed transancestry data. We then compared MEGASTROKE and GIGASTROKE results for European participants while holding the estimated genetic effects on iron and the three instruments fixed. This isolates the change in stroke data. We also examined precision at nearby variants carrying the same iron signal and at variants elsewhere in the genome.

Results

Reconstruction and updated estimate

Using the published, rounded coefficients describing each variant’s association with iron and the original three variants, we obtain an odds ratio (OR) of 1.158 per standard-deviation increase in serum iron for transancestry MEGASTROKE cardioembolic stroke. Its 95% confidence interval (CI) is 1.014–1.322, closely matching the published 1.16 (1.01–1.32). An odds ratio above one indicates higher odds of stroke; a value of one indicates no association. The European reconstruction is also positive. European GIGASTROKE gives an estimate near no association, with wider intervals (Table 1). Its uncertainty allows both lower and higher stroke odds, so this update leaves the effect unresolved.

Table 1. Serum-iron estimates using the same exposure coefficients and exact instruments. “Random” denotes multiplicative random-effects intervals, which allow for disagreement among variant estimates. Q measures this disagreement and has two degrees of freedom (df). SE is standard error, a measure of the estimate’s uncertainty. Log-OR is the natural logarithm of the odds ratio.

Cardioembolic outcome OR Fixed 95% CI Random 95% CI Fixed log-OR SE Q (2 df)
MEGASTROKE, transancestry 1.158 1.014–1.322 1.001–1.338 0.0678 2.38
MEGASTROKE, European 1.188 1.033–1.366 1.033–1.366 0.0714 1.51
GIGASTROKE, European 0.999 0.836–1.194 0.680–1.468 0.0911 9.28

The loss of precision is visible in the stroke associations before scaling them by iron effects. Outcome standard errors at C282Y, H63D and TMPRSS6 rise from 0.0416, 0.0277 and 0.0194 in European MEGASTROKE to 0.0507, 0.0334 and 0.0266 in European GIGASTROKE. The MR log-OR standard error rises from 0.0714 to 0.0911. The comparison within European results rules out the change from transancestry to European data as the explanation.

GIGASTROKE's European cardioembolic sample has 10,804 cases. Its source table assigns 6,189 to unchanged MEGASTROKE cohorts, 718 to updated cohorts and 3,897 to new cohorts. These labels describe cohorts rather than individual overlap. We therefore compare the releases without pooling them or testing their difference as independent estimates. Mishra et al., 2022

Nearby HFE variants

Nearby HFE variants carry almost identical measured iron associations but have more than twice the stroke information. This checks whether markers tracking the same iron signal share the loss of precision. The markers rs79220007 and rs198851 track C282Y and H63D, respectively, with observed dosage correlation r²=1 in 503 European participants from the 1000 Genomes genetic reference dataset. An allele is a particular form of a genetic variant. This correlation means that their measured allele counts track each other perfectly in that reference sample. We checked which alleles at each pair are inherited together. In GIGASTROKE cardioembolic results, these linked markers, or tags, have 2.318 and 2.284 times the inverse-variance information of the original variants. This measure is the reciprocal of the squared standard error; higher values mean more precise estimates.

The tags also have nearly identical measured iron effects. FinnGen, a Finnish genetics research resource, provides clinical laboratory measurements through its Kanta study. After aligning the alleles inherited together, the tag/original iron-effect coefficient ratios in Kanta are 0.998866 and 0.996455. Thus stronger iron associations at the tags do not explain their better stroke precision. Kanta uses each person’s median clinical laboratory iron measurement in 56,958 participants, then transforms the ranked values to a normal distribution. This inverse-normalized measure differs in scale from the original population iron assays. Kanta documentation

With Kanta coefficients throughout, the cardioembolic OR using the three original variants is 1.013 (fixed 95% CI 0.773–1.328). Replacing only the two HFE variants gives 1.209 (0.993–1.472). Random-effects intervals are wide at 0.565–1.814 and 0.751–1.946. These fits show how marker choice affects the estimate; the tags were selected after inspecting precision. A nearby TMPRSS6 marker, rs4820268, provides another comparison. It has r²≈0.76 with rs855791 and is too weakly correlated to serve as an interchangeable proxy.

Availability across stroke subtypes

The original iron instruments have low information across several stroke outcomes and disappear from the small-vessel results. To compare precision across variants with different allele frequencies, we calculate an information diagnostic, I=1/[2f(1-f)SE^2], where f is allele frequency and SE is the stroke log-OR standard error. We divide it by the median among common variants in the same 500 kilobase (kb) region. Higher values mean greater frequency-adjusted precision; the diagnostic is not a measured sample size.

The original instruments have about 60–66% of local median information for any stroke, 57–63% for ischemic stroke and 38–43% for cardioembolic stroke. The nearby comparison markers remain close to their local medians (Figure 1).

Information and availability at the same six variants across stroke outcomes

Figure 1. Relative information and availability in European GIGASTROKE. Cells show information divided by the common-variant median in the same 500 kb region. Dashed cells indicate absence. The outcomes overlap, and the TMPRSS6 comparison is only partially correlated with its original variant.

The subtype results distinguish strokes involving large arteries from those involving small vessels. Large-artery stroke retains only H63D from the original panel; small-vessel stroke retains none. Full scans of 5,784,788 original large-artery and 5,974,028 original small-vessel rows confirm these five absences before processing by the GWAS Catalog, a repository of genome-wide association study results that standardizes data formats and variant descriptions. Gill and colleagues already used only two instruments for small-vessel stroke because C282Y and a suitable proxy were unavailable in MEGASTROKE. GIGASTROKE therefore extends an existing coverage problem: none of the original three is available for this subtype. Using whichever instruments remain would compare different genetic experiments across subtypes. Gill et al., 2018

Genome-wide precision and availability

Low cardioembolic information accompanies extensive absence from small-vessel results across the genome. We extended the audit to common variants present in the original European cardioembolic file, defining common as minor-allele frequency (MAF) ≥0.05. MAF is the frequency of the less common form of a variant. Here we normalized information by chromosome medians. Excluding chromosomes 6 and 22, which contain the iron instruments, leaves 5,004,338 variants. Of these, 58,429 have information below half their chromosome median. Small-vessel results lack 88.05% of this low-information group, compared with 0.65% of other common variants (Table 2).

Table 2. Subtype availability outside chromosomes 6 and 22, grouped by cardioembolic information. Variants are correlated and outcomes overlap, so the counts are descriptive rather than independent observations for significance testing.

Cardioembolic information Variants Absent: large artery Absent: small vessel
Below half chromosome median 58,429 28,146 (48.17%) 51,449 (88.05%)
Other common variants 4,945,909 49,491 (1.00%) 32,257 (0.65%)

The pattern persists at high allele frequency. Among variants with MAF 0.30–0.50, small-vessel results lack 14,983/17,032 (88.0%) low-information variants and 191/1,647,717 (0.0116%) other variants. Across four frequency strata, the low-information group has median normalized cardioembolic information near 0.42.

Genotyping arrays measure a predefined set of genetic variants. Their marker lists and manufacturer names do not explain the general deficit. The original iron variants appear on a HumanExome array manifest, a list of markers targeted by that array. Outside chromosomes 6 and 22, low information is more common among manifest markers than other variants (7.55% versus 1.14%), but most affected variants fall outside the manifest. Among markers with numeric manufacturer identifiers beginning with “exm”, having multiple names also fails to identify the low-information group: its frequency is 8.78% for markers with multiple names and 11.69% for those with one name (Figure 2).

Genome-wide subtype dropout by allele frequency and the manufacturer-name comparison

Figure 2. Variant absence and manufacturer names. Both panels exclude chromosomes 6 and 22. Left: small-vessel absence by cardioembolic information group and MAF. Right: low-information fractions among markers with numeric “exm” identifiers grouped by number of manufacturer names.

Earlier SiGN results

Most selected low-information variants had normal relative precision in the earlier Stroke Genetics Network (SiGN) results. This historical comparison tests whether the later deficit was already present in an earlier stroke dataset. Before extracting their results from public European SiGN files, we fixed 40 low/normal-information pairs matched on chromosome, HumanExome membership, allele frequency and position. All have later cardioembolic MAF ≥0.30. SiGN dataset

The earlier outcomes are cardioembolic stroke and small-artery occlusion, a stroke subtype involving blockage of a small artery. Both contain 38/40 low-information markers and all 40 normal comparators. Of the low markers, 36 contribute to every reported analysis stratum, or separately analyzed participant group; all 40 comparators do. For the same 38 pairs with both markers present, the median ratio of information at the low-information marker to its matched normal-information marker is 1.000 in each earlier outcome and 0.416 in later cardioembolic results (Table 3). Later small-vessel results omit 39/40 low markers and retain all 40 comparators.

Table 3. Historical coverage and information in the fixed panel. Groups are defined from GIGASTROKE cardioembolic information. Presence and participation use all 40 pairs; both information medians use the identical 38 complete pairs. CES denotes cardioembolic stroke. Ratios compare information within pairs.

Earlier outcome Low present Normal present All strata: low; normal SiGN median ratio (38 pairs) GIGASTROKE CES ratio (same 38)
SiGN cardioembolic 38/40 40/40 36/40; 40/40 1.000 0.416
SiGN small artery 38/40 40/40 36/40; 40/40 1.000 0.416

All six variants examined around the iron genes are present in SiGN and contribute across all 10 reported cardioembolic and 9 small-artery strata. HFE tag/original inverse-variance ratios are 0.997 and 1.000 for cardioembolism and 1.000 for both small-artery pairs. The later precision disparity and variant loss therefore vary by dataset.

Information in the fixed matched panel across later and earlier stroke releases

Figure 3. Information ratios in earlier SiGN and later GIGASTROKE. Each point is a matched pair. Pairs were selected for their contrasting GIGASTROKE information, shown on the x-axis. SiGN information, shown on the y-axis, was unused in selection. Dashed horizontal lines indicate equal information within a pair; dotted diagonals indicate equal ratios across releases. Each panel shows 38 complete pairs. Two low markers are absent and two others have incomplete stratum participation. All remain in the coverage denominators.

Methods

Study design and Mendelian randomization

The analyses were exploratory. The reconstruction came before checks of regional precision, selection of linked markers, calibration against measured iron effects, and comparisons of subtype availability, genome-wide annotations and earlier data. The array-content test was specified before genome-wide matching; the marker-name multiplicity hypothesis was developed afterward. The historical panel was selected before its SiGN results were extracted. This order matters because the tag comparisons were informed by observed precision, whereas the earlier SiGN results were unused in panel selection.

We extract genetic associations with iron from Gill's supplement, using coefficients from the Genetics of Iron Status (GIS) study, a study of genetic associations with iron biomarkers. We preserve allele frequencies and align the iron and stroke associations to the same allele. H63D has C/G alleles, a palindromic pair that looks the same on opposite DNA strands; allele frequency resolves their alignment. The primary reconstruction uses the three exact variants. For iron coefficients b_X, stroke log-ORs b_Y and their standard errors SE_Y, the inverse-variance-weighted estimate is

\hat\theta=\frac{\sum b_Xb_Y/SE_Y^2}{\sum b_X^2/SE_Y^2},\qquad SE(\hat\theta)=\left(\sum b_X^2/SE_Y^2\right)^{-1/2}.

Random-effects standard errors multiply this by \sqrt{\max(1,Q/(k-1))}, where k is the number of variants and Q measures heterogeneity. Intervals use ±1.96 SE on the log scale. A delta-weighted sensitivity analysis includes uncertainty in the genetic associations with iron when calculating the variance of each stroke-to-iron ratio. The published exposure coefficients are rounded. The two HFE variants have reference correlation r=0.074; the primary fit follows the original reconstruction by weighting each variant separately, without including correlations in the weights. The three variants represent two genetic regions, and the correlated iron biomarkers supply related estimates.

Data and information measures

The GWAS Catalog identifiers for MEGASTROKE cardioembolic results are GCST005842 (transancestry) and GCST006910 (European). European GIGASTROKE accessions GCST90104539–GCST90104543 cover any, ischemic, cardioembolic, large-artery and small-vessel stroke. We use univariate releases, which analyze each stroke outcome separately. Variant positions are expressed using two versions of the human reference genome, GRCh38 and GRCh37. Regional queries use standardized GRCh38 coordinates and verified alleles; original-file availability and genome-wide matching use GRCh37 coordinates plus allele sets. GIGASTROKE used ancestry-specific fixed-effect meta-analysis, which combines cohort estimates assuming a shared effect, with cohort- and meta-analysis-level quality control, including participation and heterogeneity filters. GIGASTROKE methods

Information medians use common variants in two fixed 500 kb windows for regional comparisons and on the same chromosome for genome-wide comparisons. The genome-wide universe contains 5,422,856 cardioembolic variants before excluding chromosomes 6 and 22. The HumanExome v1.2 array marker list is matched by GRCh37 coordinate and forward-strand allele set, combining duplicate probes targeting the same variant. Auxiliary annotations from another array, Omni5Exome v1.0, supply the number of manufacturer names assigned to each marker. HumanExome manifest; manufacturer files

The historical panel includes the 20 autosomes (non-sex chromosomes) that do not contain the iron instruments. Each chromosome contributes one pair of HumanExome markers and one pair of markers outside that array. Both markers have MAF ≥0.30, differ by ≤0.02 in MAF and lie ≤1 megabase (Mb) apart. Low information is <0.5 chromosome median; normal is 0.9–1.1. A deterministic hash-based ordering selects eligible low markers and distance selects comparators, without using SiGN results. We extract European cardioembolism and small-artery occlusion results classified by the Trial of Org 10172 in Acute Stroke Treatment (TOAST) system. Stratum participation comes from direction strings, which record the direction or absence of each stratum’s association. We check these counts against heterogeneity degrees of freedom plus one. SiGN’s reported effective sample size is retained separately from our information diagnostic. SiGN publication and supplement

All three complete original subtype files match their deposited MD5 checksums, verifying file integrity. Independent weighted regression checks MR arithmetic, independent raw-row parsing checks information calculations, and independent full-file scans verify all 86 requested SiGN positions per outcome, including absences.

Interpretation

At these iron instruments, the larger stroke release supplies a less precise test and incomplete subtype coverage. The earlier public SiGN results show that most selected low-information variants once had precision comparable to matched markers. Exact variant availability and outcome standard errors should therefore accompany MR updates and subtype comparisons. Nearby tags can help diagnose a precision problem when their exposure effects are measured and their selection rule is explicit.

The cause of the deficit remains unresolved. Cohort inputs and participation records from before and after quality control could locate where precision and availability changed. Public SiGN differs from the non-overlapping subset submitted to GIGASTROKE, and the public meta-analysis files lack per-variant participation and exclusion reasons. The selected high-frequency panel cannot estimate genome-wide historical prevalence, and our genome-wide audit covers only variants present in cardioembolic results. Manufacturer annotations do not establish actual cohort genotyping or submitted names. Differences in participation, imputation (inferring unmeasured variants), estimation or quality-control filtering could explain the deficit. The causal iron effect also remains uncertain: the releases share cohorts, the tags were precision-selected, reference correlations may vary across cohorts, and iron-regulatory variants may affect stroke through other pathways. These estimates do not establish the effect of an iron intervention.

References and acknowledgments

  1. Gill D et al. Iron Status and Risk of Stroke. Stroke (2018). doi:10.1161/STROKEAHA.118.022701.
  2. Benyamin B et al. Novel loci affecting iron homeostasis and their effects in individuals at risk for hemochromatosis. Nature Communications (2014). doi:10.1038/ncomms5926.
  3. Malik R et al. Multiancestry genome-wide association study of 520,000 subjects identifies 32 loci associated with stroke and stroke subtypes. Nature Genetics (2018). doi:10.1038/s41588-018-0058-3.
  4. Mishra A et al. Stroke genetics informs drug discovery and risk prediction across ancestries. Nature (2022). doi:10.1038/s41586-022-05165-3.
  5. Barad A et al. Associations Between Genetically Predicted Iron Status and Cardiovascular Disease Risk: A Mendelian Randomization Study. Journal of the American Heart Association (2024). doi:10.1161/JAHA.124.034991.
  6. Allara E et al. Novel loci and biomedical consequences of iron homoeostasis variation. Communications Biology (2024). doi:10.1038/s42003-024-07115-3.
  7. NINDS Stroke Genetics Network and International Stroke Genetics Consortium. Loci associated with ischaemic stroke and its subtypes (SiGN): a genome-wide association study. Lancet Neurology (2016). doi:10.1016/S1474-4422(15)00338-5.

We thank the participants and investigators of the source studies. The MEGASTROKE project received funding from sources specified at its acknowledgments page; its requested consortium author-list supplement preserves source names and affiliations. These are source-study contributors, not authors of this reanalysis. We acknowledge GIGASTROKE, FinnGen and its public laboratory genome-wide association resource, and SiGN and the International Stroke Genetics Consortium (ISGC) through the Cerebrovascular Disease Knowledge Portal.